MICRO GEL RANGE VRLA
Open the catalog to page 1power your applications Maintenance-Free Rechargeable Sealed V.R.L.A. Lead Acid Batteries Capacities: 4.0AH to 26AH MICRO GEL superior valve regulated lead acid (VRLA) rechargeable batteries are designed to provide outstanding performance in withstanding overcharge, over discharge, and resisting vibration and shock. With compact design, these batteries save installation space, while providing full and reliable power. The use of special sealing epoxies, groove case and cover construction, and long-sealing paths for posts and connectors, assures that the VRLA battery will offer exceptional leak...
Open the catalog to page 2MICRO GEL RANGE VRLA CONSTRUCTION - The positive and negative grids are cast from a calcium / tin lead alloy to reduce grid growth and corrosion. The active material is manufactured from high purity lead (99.9999%) to minimize the negative effects of impurities. Gel Separator is mat of random woven acid resistant glass fibres. “U wrapping” is employed to eliminate the risk of short circuits due to mossing and debris at the bottom of the cell. The purpose of the separator is to maintain a constant distance between the positive and negative plates, thus removing the possibility of short circuits...
Open the catalog to page 3power your applications MICRO GEL Range General Specifications Copyright © EverExceed Corporation. All rights reserved. M □ Q 003 www.everexceed.com
Open the catalog to page 4power your applications MICRO GEL RANGE VRLA MICRO GEL Range Electrical Specifications M □ Q IS www.everexceed.com Copyright © EverExceed Corporation. All rights reserved. 04
Open the catalog to page 5power your applications MICRO GEL Range Discharge Data Amps at 20°C (68oF) Discharge Data Time in minutes I Part No. Final VPC 5 10 15 20 25 30 45 60 90 120 180 240 Actual battery performance data may be + / -5% of figures shown above. Copyright © EverExceed Corporation. All rights reserved. 05
Open the catalog to page 6power your applications MICRO GEL RANGE VRLA MICRO GEL Range Discharge Data Amps at 20°C (68oF) Discharge Data Time in minutes I Part No. Final VPC 5 10 15 20 25 30 45 60 90 120 180 240 Actual battery performance data may be + / -5% of figures shown above. Copyright © EverExceed Corporation. All rights reserved. 06
Open the catalog to page 7power your applications MICRO GEL Range Discharge Data Watts per cell at 20°C (68oF) Discharge Data Time in minutes I Part No. Final VPC 5 10 15 20 25 30 45 60 90 120 180 240 Actual battery performance data may be + / -5% of figures shown above. Copyright © EverExceed Corporation. All rights reserved. 07
Open the catalog to page 8power your applications MICRO GEL RANGE VRLA MICRO GEL Range Discharge Data Watts per cell at 20°C (68oF) Discharge Data Time in minutes I Part No. Final VPC 5 10 15 20 25 30 45 60 90 120 180 240 Actual battery performance data may be + / -5% of figures shown above. ]0Copyright © EverExceed Corporation. All rights reserved. 08
Open the catalog to page 9power your applications Battery Life Battery Life depends on a number of key factors, these include: Operating temperature of the battery; Actual use of the products i.e. Float or cycle service; Method of charging; Correct sizing etc. Float Service The float service is effected by the factors listed above and the number / depth of discharge the battery suffers during its life time. Basically the more discharges suffered and the deeper the discharges, the shorter battery life. Cycle Service Giving due consideration to the above key factors, the actual life of a battery in cycle service is dependent...
Open the catalog to page 10power your applications MICRO GEL RANGE VRLA Supplementary Charge It may be necessary to give the batteries a re-fresh charge during the storage of the batteries, maximum recommended storage times are detailed below, if storage exceeds these times or the open circuit voltage of a battery being stored falls below 12.40 volts per battery (6.2 volts per battery) then it is recommended that the batteries be given a re-fresh charge immediately at 2.25-2.35 VPC for no less than 12 hours. In discharging a battery, lead sulphate (sulphation) is formed. If the battery is recharged as soon as discharging...
Open the catalog to page 11Supplied Worldwide by EverExceed Corporation
Open the catalog to page 122 Pages
2 Pages
4 Pages
1 Page
1 Page
5 Pages
2 Pages
2 Pages
3 Pages
4 Pages
6 Pages
2 Pages
6 Pages
3 Pages
10 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
14 Pages
11 Pages
12 Pages
15 Pages
13 Pages
13 Pages
13 Pages
13 Pages
13 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
5 Pages
2 Pages
3 Pages
2 Pages
2 Pages
11 Pages
8 Pages
2 Pages
6 Pages
10 Pages
10 Pages
11 Pages
18 Pages
9 Pages
12 Pages
13 Pages
13 Pages
12 Pages
12 Pages
16 Pages
14 Pages
4 Pages
10 Pages
14 Pages
13 Pages
15 Pages
13 Pages
3 Pages
6 Pages
4 Pages
2 Pages
5 Pages
2 Pages
5 Pages
4 Pages
2 Pages
12 Pages
32 Pages