AINO MICRO Range VRLA
Open the catalog to page 1power your applications AINO MICRO Range VRLA □ Medical equipment 1 Consumer electronics □ Portable equipment 1 Toys and hobbies 1 Marine instruments Maintenance-Free Rechargeable Sealed V.R.L.A. Lead Acid Batteries Capacities: 0.8AH to 70AH AINO MICRO superior valve regulated lead acid (VRLA) rechargeable batteries are designed to provide outstanding performance in withstanding overcharge, over discharge, and resisting vibration and shock. With compact design, these batteries save installation space, while providing full and reliable power. The use of special sealing epoxies, groove case and...
Open the catalog to page 2AINO MICRO Range VRLA CONSTRUCTION - EverExceed AINO MICRO Range AGM battery construction is as shown in the diagram below. The positive and negative grids are cast from a calcium / tin lead alloy to reduce grid growth and corrosion. The active material is manufactured from high purity lead (99.9999%) to minimize the negative effects of impurities. Separator is mat of random woven acid resistant glass fibres, which acts as sponge - soaking up and immobilizing the electrolyte whilst maintaining good acid to plate contact and availability during discharge. “U wrapping” is employed to eliminate...
Open the catalog to page 3AINO MICRO Range VRLA EverExceed power your applications Copyright © EverExceed Corporation. All rights reserved 03
Open the catalog to page 4AINO MICRO Range VRLA EverExceed® power your applications Copyright © EverExceed Corporation. All rights reserved 04
Open the catalog to page 5power your applications AINO MICRO Range Discharge Data Amps at 20°C (68°F) Discharge Data Time in minutes 1 Actual battery performance data may be +/-5% of figures shown above. Copyright © EverExceed Corporation. All rights reserved
Open the catalog to page 6AINO MICRO Range VRLA EverExceed® power your applications Actual battery performance data may be +/-5% of figures shown above. VRLA www.everexceed.com Copyright © EverExceed Corporation. All rights reserved 06
Open the catalog to page 7power your applications AINO MICRO Range Discharge Data Amps at 20°C (68°F) Discharge Data Time in minutes 1 Actual battery performance data may be +/-5% of figures shown above. Copyright © EverExceed Corporation. All rights reserved
Open the catalog to page 8AINO MICRO Range VRLA EverExceed® power your applications Actual battery performance data may be +/-5% of figures shown above. Copyright © EverExceed Corporation. All rights reserved
Open the catalog to page 9power your applications AINO MICRO Range Discharge Data Watts per cell at 20°C (68°F) Discharge Data Time in minutes 1 Actual battery performance data may be +/-5% of figures shown above. Copyright © EverExceed Corporation. All rights reserved
Open the catalog to page 10power your applications AINO MICRO Range VRLAAINO MICRO Range Discharge Data Watts per cell at 20°C (68°F) Discharge Data Time in minutes 1 Actual battery performance data may be +/-5% of figures shown above. VRLA www.everexceed.com Copyright © EverExceed Corporation. All rights reserved 10
Open the catalog to page 11power your applications Battery Life Battery Life depends on a number of key factors, these include: n Operating temperature of the battery; n Actual use of the products i.e. Float or cycle service; □ Method of charging; □ Correct sizing etc. Float Service The float service is effected by the factors listed above and the number / depth of discharge the battery suffers during its life time. Basically the more discharges suffered and the deeper the discharges, the shorter battery life. Cycle Service Giving due consideration to the above key factors, the actual life of a battery in cycle service...
Open the catalog to page 12AINO MICRO Range VRLA EverExceed power your applications Supplementary Charge It may be necessary to give the batteries a re-fresh charge during the storage of the batteries, maximum recommended storage times are detailed below, if storage exceeds these times or the open circuit voltage of a battery being stored falls below 12.40 volts per battery (6.2 volts per battery) then it is recommended that the batteries be given a re-fresh charge immediately at 2.25-2.35 VPC for no less than 12 hours. In discharging a battery, lead sulphate (sulphation) is formed. If the battery is recharged as soon...
Open the catalog to page 13power your applications Supplied Worldwide by EverExceed Corporation
Open the catalog to page 142 Pages
2 Pages
4 Pages
1 Page
1 Page
5 Pages
2 Pages
2 Pages
3 Pages
4 Pages
6 Pages
2 Pages
6 Pages
3 Pages
10 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
14 Pages
11 Pages
12 Pages
15 Pages
13 Pages
13 Pages
13 Pages
13 Pages
13 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
5 Pages
2 Pages
3 Pages
2 Pages
2 Pages
11 Pages
8 Pages
2 Pages
6 Pages
10 Pages
10 Pages
11 Pages
18 Pages
9 Pages
12 Pages
13 Pages
13 Pages
12 Pages
12 Pages
16 Pages
4 Pages
12 Pages
10 Pages
14 Pages
13 Pages
15 Pages
13 Pages
3 Pages
6 Pages
4 Pages
2 Pages
5 Pages
2 Pages
5 Pages
4 Pages
2 Pages
12 Pages
32 Pages