i High Temperature Battery Series Telecom MAX Range VRLA Unique performance against high temperature Premium quality for uninterruptible application

Open the catalog to page 1
Telecommunications equipment battery TM-12 series - 2

Applicable Operating temperature range: -40°C (-40°F) to + 80°C (+176°F) Ideal Operating temperature range: +15°C (+59°F) to + 35°C (+95°F) Storage time from a fully charged condition: 12 months at 20°C~25°C / 68°F~77°R for each 9°C / 15°F rise, reduce the storage time by half. How our High Temperature battery (HTB) solution is the best? Excellent high temperature performance The extremely powerful, compact AGM VRLA batteries of EverExceed Telecom Max Range is designed to cope with the most extreme temperatures and environments, which is an ideal energy source for durability in...

Open the catalog to page 2
Telecommunications equipment battery TM-12 series - 3

Why choose our High Temperature Telecom Max Range battery over regular Lead-acid Battery? Item Regular VRLA battery Technologies Expected Service Life (35°C) Operating temperature Fast charge performance PSOC performance Water loss performance Avoid thermal runaway >80% DOD Cycle life <80% DOD Float life Cost comparison between our High Temperature Max Range battery over regular Lead-acid Battery 6000 Initially the CAPEX of HTB series batteries are little higher than the regular VRLA Batteries, but user need to invest on additional air-condition system for the regular VRLA batteries to keep...

Open the catalog to page 3
Telecommunications equipment battery TM-12 series - 4

Battery Model Short Circuit Battery Weight (kg/lb) ! Dimensions (mm/inch) • Plates: High Tin Pb alloy, optimized for high corrosion resistance and deep cycle use. • Separator: Highly porous glass micro-fibre separator, optimized for low internal resistance, for maximum Absorption of the electrolyte and for electrical separation. • Standard housing: Reinforced special high temperature resistant ABS container and cover adopted. • Terminals: Silver plated Copper female insert for easy and safe assembly and maintenance free connection with excellent conductivity. • Valves: Release gas in case...

Open the catalog to page 4
Telecommunications equipment battery TM-12 series - 5

Telecom Max Range Discharge Ampere Hour Data @ 25°C (77°F) Battery Model Discharge Data Amps @ 20°C Discharge Time In Minutes Discharge Data Ampere Hours @ 25°C Discharge Time In Hours

Open the catalog to page 5
Telecommunications equipment battery TM-12 series - 6

Telecom Max Range Discharge Ampere Hour Data @ 25ºC (77ºF) Discharge Data Amps @ 20ºC Battery Model Discharge Data Ampere Hours @ 25ºC Discharge Time In Minutes Discharge Time In Hours 1.5 Telecom Max Range Discharge Ampere Data @ 25ºC (77ºF) Discharge Data Amps @ 20ºC Battery Model Discharge Data Amps @ 25ºC End VPC Discharge Time In Minutes 5 Discharge Time In Hours 1.5

Open the catalog to page 6
Telecommunications equipment battery TM-12 series - 7

Telecom Max Range Discharge Ampere Data @ 25°C (77°F) Discharge Data Amps @ 20°C Discharge Data Amps @ 25°C Battery Model Discharge Time In Minutes Telecom Max Range Discharge Watts Per Cell (WPC) Data @ 25°C (77°F) 22.8 1.8 Discharge Data Watts Per Cell @ 25°C Discharge Time In Hours 2.4

Open the catalog to page 7
Telecommunications equipment battery TM-12 series - 8

Battery Model Discharge Data WPC @ 25°C Discharge Time In Minutes Discharge Data Watts Per Cell @ 25°C Discharge Time In Hours

Open the catalog to page 8
Telecommunications equipment battery TM-12 series - 9

Characteristic Curves for Telecom MAX Range battery Recharge Characteristics 2.27 VPC float @ 25°C (77°F) 110 Recharge voltage Recharge current Time, Hours Float Voltage & Charging Charging voltage in V per cell Constant Voltage charging is recommended Recommended float voltage: 2.27VPC @ 25ºC(77ºF) Float Voltage Range: 2.24VPC @ 35ºC(95ºF) Equalize voltage: 2.35VPC for 12 Hours Equalizing charge voltage for max 12 hours 2.4 For charging 2.27 V/cell is recommended. The charging voltage must be compensated according to the curve for continuously different battery ambient temperature....

Open the catalog to page 9
Telecommunications equipment battery TM-12 series - 10

Characteristic Curves for Telecom MAX Range battery 120 Electrolyte freezing area Extracted capacity in relation to the temperature. Storage in months Self-discharge in relation to the storage temperature. Depth of Discharge (DOD) Life cycle in relation to the depth of discharge @25

Open the catalog to page 10
Telecommunications equipment battery TM-12 series - 11

i High Temperature Battery Series Telecom MAX Range VRLA Unique performance against high temperature

Open the catalog to page 11