One of the best solutions for BANK BRANCH ATM MACHINE All in one solution with UPS, batteries and MCB inside! Plug and Play! Easy Installation!
Open the catalog to page 1Downtime caused by power outages can be financially crippling for a business or organization. Every year, billions of dollars are lost due to downtime caused by power disruptions. That's why an UPS is used in Banking sectors, Stock Exchange, ATM machines as an alternative to provide emergency power to a load when the main input power source fails. Considering the importance of the uninterruptable power supply EverExceed Integrated long backup UPS system is one of the best financial viable solution. Integrated long backup UPS system consists of EverExceed PLRM1 UPS, EverExceed high performance battery...
Open the catalog to page 2Wide range of input voltage while input PF>99%. LCD/ LED display helps to monitor all the operation status. High-efficiency up to 95%, driving up cost savings and improving energy consumption. Output power factor of 0.8. Long backup time up to 24 hrs. (customizable as per customer requirement). Zero transfer time. Compatible with NiCd, VRLA (valve-regulated leadacid battery), Lithium Iron Phosphate (LiFePO4). Standardized power distribution architectures in compliance with the Uptime Institute classification system and EN 50600. Connectivity for optional communication boards including USB, SNMP,...
Open the catalog to page 3EverExceed All in One UPS system is compatible with EverExceed high performance and long service life Lead Acid, NiCd or Lithium batteries. Also the system can be designed as per customer requirement. Features of HTB series VRLA battery Thick plate design for long service life: 12-15 years @ 35˚C(95˚F); High sustainable temperature range: -40°C to +80°C; Nano-Carbon enhanced material for improved durability; Advanced corrosion-resistant lead, high-tin (1.5%), low-calcium alloy; Up to 100% air conditioner maintenance saving; Reinforced anti-high temperature ABS container and cover;...
Open the catalog to page 4TECHNICAL DATA Model Input Phase Single phase in, single phase out Voltage range Frequency adaptable Power factor Output Voltage Power factor THD linear load, ≤5% THD, no-linear load Frequency range System Overload capability (inverter mode) Overload capability (ba ery mode) 110%, transfer to bypass a er 10 minutes (105-130)%, transfer to bypass a er 1 minute 125% to bypass a er 1min, 150% to bypass a er 30 seconds and shutdown a er 1 minute 150%, transfer to bypass a er 30 seconds (105-130)%, transfer to bypass a er 10 seconds 150%, transfer to bypass a er 5 seconds 110%; shutdown a er 1 min,...
Open the catalog to page 52 Pages
2 Pages
4 Pages
1 Page
1 Page
5 Pages
2 Pages
2 Pages
3 Pages
4 Pages
6 Pages
2 Pages
6 Pages
3 Pages
10 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
14 Pages
11 Pages
12 Pages
15 Pages
13 Pages
13 Pages
13 Pages
13 Pages
13 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
5 Pages
2 Pages
3 Pages
2 Pages
2 Pages
11 Pages
8 Pages
2 Pages
6 Pages
10 Pages
10 Pages
11 Pages
18 Pages
9 Pages
12 Pages
13 Pages
13 Pages
12 Pages
12 Pages
16 Pages
14 Pages
4 Pages
12 Pages
10 Pages
14 Pages
13 Pages
15 Pages
13 Pages
3 Pages
6 Pages
4 Pages
2 Pages
5 Pages
2 Pages
5 Pages
4 Pages
2 Pages
12 Pages
32 Pages