power your applications
Open the catalog to page 1power your applications Front Access FT AGM Range VRLA SEALED VRLA MONOBLOC AGM BATTERIES Capacities: 55AH to 200AH at C10 The extremely powerful, compact AGM batteries of EverExceed front access FT Range are an ideal energy source for durability in Telecommunications and Electric Utility applications. The EverExceed front access FT Range VRLA provides high performance and reliability in long duration discharge applications. Our development team combines the market's demand with design optimization, precision component selection and state-of-the-art manufacturing process to produce the most cost...
Open the catalog to page 2Front Access FT AGM Range VRLA CONSTRUCTION - EverExceed’s front access FT Range AGM battery construction is as shown in the diagram below. The positive and negative plates are cast from a Lead-Calcium-Tin alloy to reduce grid growth and corrosion. The active material is manufactured from high purity lead (>99.994%) to minimize the negative effects of impurities. Separator is superior quality microporous mat of random woven acid resistant glass fibres, with high absorption and stability, which acts as sponge - soaking up and immobilizing the electrolyte whilst maintaining good acid to plate contact...
Open the catalog to page 3power your applications Front Access FT AGM Range Electrical Specifications & Dimensions Terminal and Torque Length Battery Model 12 years Design Life Grid Plate Monobloc Battery Nominal Capacity 55~200Ah Deep Discharge Recovery Maintenance Free Recyclable Valve Regulated Lead Acid Float Voltage & Charging Constant voltage charging is recommended Recommended float voltage: 13.5V @ 20°C(68°F) Float voltage range: 13.5V to 13.8V @ 20°C(68°F) Equalize voltage: 14.1V for 12 Hours VRLA www.everexceed.com 03 Copyright © EverExceed Corporation. All rights reserved.
Open the catalog to page 4power your applications Front Access FT AGM Range VRLA Front Access FT AGM Range VRLA Discharge Ampere Hours Data @ 20°C Battery Model Actual Battery Discharge Data may be +/-5% of figures shown above. www.everexceed.com Copyright © EverExceed Corporation. All rights reserved. 04
Open the catalog to page 5power your applications Front Access FT AGM Range VRLA Discharge Ampere Hours Data @ 20°C Battery Model Actual Battery Discharge Data may be +/-5% of figures shown above. 05 Copyright © EverExceed Corporation. All rights reserved VRLA
Open the catalog to page 6power your applications Front Access FT AGM Range VRLA Front Access FT AGM Range VRLA Discharge Amps Data @ 20°C Battery Model Actual Battery Discharge Data may be +/-5% of figures shown above. www.everexceed.com Copyright © EverExceed Corporation. All rights reserved. 06
Open the catalog to page 7power your applications Front Access FT AGM Range VRLA Discharge Amps Data @ 20°C Battery Model Actual Battery Discharge Data may be +/-5% of figures shown above. 07 Copyright © EverExceed Corporation. All rights reserved VRLA
Open the catalog to page 8power your applications Front Access FT AGM Range VRLA Front Access FT AGM Range VRLA Discharge Watts Per Cell (WPC) Data @ 20°C Battery Model Actual Battery Discharge Data may be +/-5% of figures shown above. www.everexceed.com Copyright © EverExceed Corporation. All rights reserved. 08
Open the catalog to page 9power your applications Front Access FT AGM Range VRLA Discharge Watts Per Cell (WPC) Data @ 20°C Battery Model Actual Battery Discharge Data may be +/-5% of figures shown above. 09 Copyright © EverExceed Corporation. All rights reserved VRLA
Open the catalog to page 10power your applications Front Access FT AGM Range VRLA TYPICAL CYCLIC PERFORMANCE CAPACITY WITHDRAWN CYCLES 100% 700 Copyright © EverExceed Corporation. All rights reserved. 10
Open the catalog to page 11Float Voltage & charging Constant Voltage charging is recommended Recommended float voltage: 2.27VPC @ 20°C(68°F) Float Voltage Range: 2.25VPC to 2.30 VPC @ 20°C(68°F) Equalize voltage: 2.35VPC for 12 Hours Temperature compensation: Apply for temperature range of 0°C / 32°F to 40°C / 104°F. Sub tract 3 mV / °C / cell or 1.7 mV / °F / cell, above 25°C / 77°F. Add 3mV / °C / cell or 1.7 mV / °F / cell, below 25°C / 77°F. For charging 2.27 V/cell is recommended. The charging voltage must be compensated according to the curve for continuously different battery ambient temperature. Recharging time...
Open the catalog to page 12power your applications power your applications Supplied Worldwide by EverExceed Corporation
Open the catalog to page 132 Pages
2 Pages
4 Pages
1 Page
1 Page
5 Pages
2 Pages
2 Pages
3 Pages
4 Pages
6 Pages
2 Pages
6 Pages
3 Pages
10 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
14 Pages
11 Pages
12 Pages
15 Pages
13 Pages
13 Pages
13 Pages
13 Pages
13 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
5 Pages
2 Pages
3 Pages
2 Pages
2 Pages
11 Pages
8 Pages
2 Pages
6 Pages
10 Pages
10 Pages
11 Pages
18 Pages
9 Pages
12 Pages
13 Pages
12 Pages
12 Pages
16 Pages
14 Pages
4 Pages
12 Pages
10 Pages
14 Pages
13 Pages
15 Pages
13 Pages
3 Pages
6 Pages
4 Pages
2 Pages
5 Pages
2 Pages
5 Pages
4 Pages
2 Pages
12 Pages
32 Pages