4-12kVA PowerLead2 series Parallel UPS
4Pages

{{requestButtons}}

Catalog excerpts

4-12kVA PowerLead2 series Parallel UPS - 1

(LV: 0.8-2KVA) Features  Wide input voltage range;  Cold start;  Advanced battery management;  Automatic battery charging on/ off mode;  Lighting and surge protection;  Automatic fan speed adjustment;  Complete protection function;  Network/fax/modem surge protection;  LCD/LED display option;  EMI/RFI noise filter;  Smart RS232 port with monitoring software;  PFC technology. RS-232 communication port (DB9 type) Network surge protection Intelligent slot USB port. B type (Option) Input surge protection slot Input socket. External battery port.

Open the catalog to page 1
4-12kVA PowerLead2 series Parallel UPS - 2

Technical data Model (LV) Capacity INPUT Acceptable Input voltage Single phase in, single phase out Input Power Factor Input Frequency Range Frequency Adaptable Normal Output Voltage Voltage Regulation SYSTEM Battery Number Battery Voltage External Battery External Battery 105%~130%: transfer to bypass after 1mins 150%: transfer to bypass after 30s 105%~130%:shutdown after 10s Overload Capability (battery mode) Crest Ratio Communication Interface Overload Capability (inverter mode) External Battery Standard:RS232, EPO Optional:SNMP,Dry Contact,USB(B Type),intelligent kits 144*353*222 10.5

Open the catalog to page 2
4-12kVA PowerLead2 series Parallel UPS - 3

(LV: 4-12KVA) Features  Wide input voltage range;  Cold start;  Advanced battery management;  Automatic battery charging on/ off mode;  Lighting and surge protection;  Automatic fan speed adjustment;  Complete protection function;  Network/fax/modem surge protection;  LCD/LED display option;  EMI/RFI noise filter;  Smart RS232 port with monitoring software;  PFC technology;  Parallel function. Rear Panel Parallel ports (12) Cable entry protector Reserved customer function SNMP card slot External battery connector Optional for standard model

Open the catalog to page 3
4-12kVA PowerLead2 series Parallel UPS - 4

Technical data Model (LV) INPUT Acceptable Input voltage Single phase in, single phase out Input Power Factor Input Frequency Range Frequency Adaptable Normal Output Voltage Voltage Regulation SYSTEM Battery Number Battery Voltage Overload Capability (inverter mode) 130%:transfer to bypass after 1minutes 150%:transfer to bypass 30s,shutdown the bypass after 1 minutes 110%:shutdown after 10minutes Overload Capability (battery mode) Crest Ratio Communication Interface Standard:RS232,EPO Optional:SNMP,USB,Parallel Kit,Maintenance Bypass,External Battery Cable,Dry contacts

Open the catalog to page 4