1-3KVA PL1 series Single phase UPS
2Pages

{{requestButtons}}

Catalog excerpts

1-3KVA PL1 series Single phase UPS - 1

PL 1 Series High frequency online UPS (1KVA - 3KVA) Sine wave output High quality sine waves can be output in both mains mode and battery mode to provide optimum power protection for the load. Zero conversion When the utility power is interrupted or restored, the UPS switches between the mains mode and the battery mode without conversion time, which eff ectively ensures the reliability of the load operation. Bypass output rationalization (optional) Other brands of online UPS in Bypass MODE, UPS can only pass through but can not protect the load, and Digital series UPS can still provide automatic regulated output when Bypass MODE, making the load more secure. TVSS function TRANSENT SURGE VOLTAGE SUPPRESS surge protection, which is used for conversion protection of FAX, TELEPHONE, MODEM, network, etc. DC start function In the power outage state, if you need to use the UPS to start the computer or other load devices, the Digital series UPS can be powered on directly in the battery mode, making the use of the UPS more convenient and reliable. Bypass protection (optional) The bypass power supply function greatly enhances the emergency handling capability of the UPS. At the same time, when the user's load equipment has special requirements on the power supply, such as the voltage can not be too high, the Digital series UPS provides bypass power supply for voltage protection, so that the user's load equipment is free protected from high voltage. Long-lasting power supply design The Digital Series UPS off ers a long-lasting machine for users to choose from. By confi guring a suitable battery pack, the discharge time of the UPS can be more than 8 hours to meet the requirements of diff erent grid environments. In addition to the extended discharge time, the Digital Series UPS long-lasting machine has a strong battery recharging capability and can provide an initial charging current of about 5A. Self-checking function The Digital Series UPS can simulate the situation of power outage to supply power from battery mode. This function can be performed at any time through the self-test button on the panel, or it can be carried out in a regular or irregular basis with the random monitoring software. Usage with generator The wide input voltage and frequency range allow the Digital Series UPS to be used with mainstream brand generators to extend the time of use while eff ectively removing the impure power generated by the generator and providing a safe and stable power supply to the load. Inductive load Digital series UPS can be connected to inductive load (PF≥0.9). Green energy-saving power supply The overall effi ciency is greater than 93%, the input power factor is greater than 0.99 and the total harmonic distortion current is less than 5%. Monitoring software In order to make the management of the UPS more convenient and eff ective, the monitoring software is randomly distributed for intelligent management. Equipped with Intelligent-Smart Slot The Digital Series UPS is equipped with an Intelligent-Smart Slot. Users can choose an SNMP network card for centralized and remot

Open the catalog to page 1
1-3KVA PL1 series Single phase UPS - 2

Electric Performance Model Load capacity Rated Frequency(HZ) Voltage(Single phase) Output Voltage tolerance Frequency tolerance(Battery Mode Linear Load THD(Full Load) Non-linear Load >105%→30s Over capacity >130%→200ms Crest Ratio Battery Voltage Battery Voltage Battery Configuration Extmal Battery Extmal Battery Extmal Battery Transfer Time Main Mode→Bypass Mode Main Mode→Battery Mode Working Environment Temperature Storage Temperature Mechanical Performance Dimension W*D*H(mm) Gross Weight

Open the catalog to page 2

All EverExceed Industrial Co. Ltd catalogs and technical brochures

  1. EHCS 7K-11K

    3 Pages

  2. Battery rack

    2 Pages

  3. UXcel series

    5 Pages

  4. CHF series

    2 Pages

  5. Smart V1.0

    4 Pages