Standard Dump Controller

Standard Dump Controller
1 / 19 PagesView full catalog

Standard Dump Controller

Product catalog summary
Safety Considerations
  • Mechanical Safety: Proper handling methods are crucial to avoid injuries during installation and maintenance.
  • Electrical Safety: Follow installation instructions, ensure proper ventilation for batteries, and use correct wire sizes to prevent fire hazards.
  • Installation Hazards: Employ careful work practices and double-check work to avoid slack bolts and loose connections.
  • Operational Safety: Be cautious of high temperatures during operation and avoid maintenance during windy conditions.
Standard Controller Overview
  • Description: The Kestrel Type 0401 Standard Controller manages power from wind turbines to safely charge batteries, using a diversion resistor for excess energy.
  • Identification and Markings: Features a product rating plate and serial number for authenticity.
  • Applications and Uses: Used with Kestrel wind turbines for battery charging, requiring additional equipment for specific applications.
Standard Controller Assembly
  • Components Supplied: Includes the Standard Controller assembly and User Manual.
  • Components Not Supplied: Additional items like electrical crimp terminals and fixing screws are needed for installation.
  • Tools Required: Necessary tools include screwdrivers and wire strippers.
  • Unpacking: Instructions for checking and identifying parts upon unpacking.
Installation Instructions
  • Typical Installation Example: Describes a setup involving a wind turbine, controller, diversion resistor, battery, and inverter.
  • Mounting the Controller: Specifies indoor installation with adequate space for cooling.
  • Electrical Wiring: Detailed steps for connecting the controller, emphasizing correct polarity and safety measures.
  • Adjusting the Charging Voltage: Instructions for setting the charging voltage based on battery type.
  • Adjusting the Switching Delay: Options for setting the delay time to prevent cycling on and off.
Wiring and Cable Sizing
  • Wind Turbine Wiring: Guidelines for extending output wires and ensuring proper connections to avoid power loss and overheating.
Electrical System Considerations All electrical systems experience energy loss due to cable resistance. The mounting structure must be earthed for lightning protection, with power cables routed inside the structure for protection. Supply cables should be buried at least 0.5 meters deep in a suitable conduit.Battery Wiring Battery wiring typically matches the turbine power wiring size, though smaller diameters can be used due to shorter distances between the charge controller and battery.Lightning Protection Proper grounding is crucial to protect against induced voltages and static. The generator should be electrically connected to the mounting structure, which is earthed by burying a steel or copper pipe horizontally below the ground. Grounding wire size should match power cables, and commercial lightning arrestors can be installed.Wire Tables Wire sizes are calculated for a 3% power loss, with recommendations for minimum sizes. Wire lengths account for a double cable run, and sizes are given in both metric and AWG.Battery Considerations Batteries should be deep cycle types, with lead acid, sealed gel, and Ni-Cad being common options. Temperature compensation is generally only useful in extreme conditions.Technical Specifications The controller models are specified for different power and current ratings, with input voltage variations and efficiency details provided. The controller features natural convection cooling and complies with EMC requirements.Troubleshooting Common issues include polarity reversal, electrical shorts, and high operating temperatures. Solutions involve checking connections, adjusting load, and using the turbine stop switch.Maintenance The controller requires no regular part replacement but should be kept clean to ensure proper airflow.Warranty Conditions The warranty covers defects for two years, subject to proper installation and use. It excludes damage from extreme winds and allows for repair, replacement, or refund at Eveready's discretion.Contact Information Kestrel Wind Turbines can be contacted via phone, email, or their website for further assistance.
See more

Catalog excerpts

Standard Dump Controller-1

Standard Controller Manual Document #: 0401M01 REV : 1.1 Approval: Date: March ‘08 Page 1 of 19 Registration Number 2006/005438/07 VAT Registration Number 4870231406 Tel: +27 (0)41 401 2500 Website: www.kestrelwind.co.za Kestrel Standard Controller Type 0401 User Manual Revision 1.1 (03-08) Revision 1.0 (12-07) For the following models of Type 0401 Standard Dump Controller Type 0401–0600-012 (e150-001-012) 600W 50A Type 0401-0600-024 (e150-001-024) 600W 35A Type 0401-0600-048 (e150-002-048) 600W 20A Type 0401-0800-012 (e220-001-012) 800W 50A Type 0401-0800-024 (e220-001-024) 800W 35A Type 0401-0800-048 (e220-001-048) 800W 20A

 Open the catalog to page 1
Standard Dump Controller-2

Standard Controller Manual Document #: 0401M01 REV : 1.1 Approval: Date: March ‘08 Page 2 of 19 CONTENTS PAGE 1 Safety Considerations 1.1 Mechanical Safety 3 1.2 Electrical Safety 3 1.3 Installation Hazards 3 1.4 Operational Safety 3 2 Standard Controller Overview 2.1 Standard Controller Description 4 2.2 Identification and Markings 5 2.3 Applications and uses 5 3 Standard Controller Assembly 3.1 Components Supplied 6 3.2 Components not Supplied 6 3.3 Tools Required 6 3.4 Unpacking 6 4 Installation Instructions 4.1 Typical Installation Example 7 4.2 Mounting the Standard Controller 8 4.3 Electrical...

 Open the catalog to page 2
Standard Dump Controller-3

Standard Controller Manual Document #: 0401M01 REV : 1.1 Approval: Date: March ‘08 Page 3 of 19 1 Saffetty Consiiderrattiions 1..1 Mechaniicall Saffetty 1..2 Ellecttrriicall Saffetty 1..3 IInsttallllattiion Hazarrds 1..4 Operrattiionall Saffetty Note: The Standard Controller Type 0401 must be installed with a separate divert resistor. DO NOT OPERATE THIS CONTROLLER WITHOUT A BATTERY CONNECTED Disclaimer Kestrel Wind Turbines makes every effort to give accurate information in this manual and is in no way liable for any error or omission. The user of this manual assumes full responsibility and...

 Open the catalog to page 3
Standard Dump Controller-4

Standard Controller Manual Document #: 0401M01 REV : 1.1 Approval: Date: March ‘08 Page 4 of 19 2 Sttandarrd Conttrrollllerr Overrviiew 2..1 Sttandarrd Conttrrollllerr Descrriipttiion 2..2 IIdenttiiffiicattiion and Marrkiings 2..3 Applliicattiion and Uses 2 STANDARD CONTROLLER OVERVIEW 2.1 Standard Controller Description IMPORTANT: A suitable divert power resistor must be installed with this product Sustainable/renewable energy sources such as wind turbines and solar panels generate uncontrolled power that must be regulated to facilitate the correct and safe charging of storage batteries. The...

 Open the catalog to page 4
Standard Dump Controller-5

Standard Controller Manual Document #: 0401M01 REV : 1.1 Approval: Date: March ‘08 Page 5 of 19 2.2 Identification and Markings On the Standard Controller enclosure is a product rating plate and serial number, if the controller does not carry this stamp it does not carry a Kestrel warranty and may not be authentic. *NOTE: Product Rating label example (above) is for format only, details may vary On the front cover of the charge controller are two switches which are labelled accordingly. Removing the front cover reveals internal connection labels. 2.3 Applications and Uses The Kestrel Standard...

 Open the catalog to page 5
Standard Dump Controller-6

Standard Controller Manual Document #: 0401M01 REV : 1.1 Approval: Date: March ‘08 Page 6 of 19 3 STANDARD CONTROLLER ASSEMBLY 3.1 Components Supplied The following components are supplied: Standard Controller assembly User Manual 3.2 Components Not Supplied The following components are necessary to complete an installation: Electrical crimp terminals Wall fixing screws 20mm cable glands Suitable fixing screws or bolts 3.3 Tools Required The following hand tools are required for Standard Controller installation: Small size electrical screwdriver Medium size electrical screwdriver Wire strippers...

 Open the catalog to page 6
Standard Dump Controller-7

Standard Controller Manual Document #: 0401M01 REV : 1.1 Approval: Date: March ‘08 Page 7 of 19 4 INSTALLATION INSTRUCTIONS 4.1 Typical Installation Example A typical battery charging installation is shown below. The system comprises a Kestrel wind turbine, a Standard Controller, diversion resistor, battery and an inverter. The inverter is additional and converts the battery dc power into standard ac power such that common mains powered appliances can be supplied. DO NOT OPERATE THIS CONTROLLER WITHOUT A BATTERY CONNECTED NOTE: The load circuit breaker and inverter are additional equipment and...

 Open the catalog to page 7
Standard Dump Controller-8

Standard Controller Manual Document #: 0401M01 REV : 1.1 Approval: Date: March ‘08 Page 8 of 19 4.2 Mounting the Controller The Kestrel Standard Controller Type 0401 is only suitable for indoor installation. The unit is vertically mounted using the four internal fixing holes provided. Use secure fastening with suitable wall plugs or bolts. Allow a minimum of 100mm (4”) space all around the unit for cooling. It is normal for the regulator to become quite hot at times as it dissipates unwanted energy. Do not place any objects on the top of the enclosure. The unit relies on the free passage of air...

 Open the catalog to page 8
Standard Dump Controller-9

Standard Controller Manual Document #: 0401M01 REV : 1.1 Approval: Date: March ‘08 Page 9 of 19 4.3 Electrical Wiring Observe the Polarity at all times. Only connect +VE RED cables to +VE RED terminals and -VE BLACK cables to -VE BLACK terminals. Otherwise, equipment damage may result and any warranty will be invalidated. PLEASE FOLLOW THE INSTRUCTIONS BELOW ! CONSULT SECTION 5 FOR WIRE SIZE RECOMMENDATIONS The Standard Controller is provided with two pairs of +VE and -VE clearly marked terminals for "TURBINE" and "BATTERY" and one pair of DIVERT RESISTOR terminals clearly marked R1A and R1B...

 Open the catalog to page 9
Standard Dump Controller-10

Standard Controller Manual Document #: 0401M01 REV : 1.1 Approval: Date: March ‘08 Page 10 of 19 4.4 Adjusting the Charging Voltage Always switch the turbine brake on (S1 ON) and the battery circuit breaker off (Q1 OFF) before adjusting the charging voltage jumper The Kestrel Standard Controller Type 0401 is suitable for all lead acid batteries whether vented, semi-sealed or sealed and the charging voltage may be adjusted. When the cover is removed, the jumper is visible in the middle of the control board. The charging voltage may be adjusted to the following table. There are five positions for...

 Open the catalog to page 10