Safety Considerations
  • Mechanical Safety: Proper handling methods are essential to prevent injuries during installation and maintenance.
  • Electrical Safety: Adhere to installation instructions, ensure adequate ventilation for battery setups, and use appropriate wire sizes to mitigate fire risks.
  • Installation Hazards: Exercise caution to avoid slack bolts and loose connections; assistance is recommended.
  • Operational Safety: Be cautious of high temperatures during operation and avoid maintenance in windy conditions.
Diversion Resistor Overview
  • Description: Designed for use with Kestrel Charge Controllers to dissipate excess electrical energy as heat.
  • Identification and Markings: Verify the presence of a rating plate and serial number for authenticity.
  • Applications and Uses: Primarily used with Kestrel wind turbines for battery charging systems.
Diversion Resistor Assembly
  • Components Supplied: Includes the diversion resistor assembly and user manual.
  • Components Not Supplied: Additional items like electrical crimp terminals and wall fixing screws are required.
  • Tools Required: Electrical screwdrivers, wire strippers, crimping pliers, and a tape measure.
  • Unpacking: Inspect for transit damage and ensure all parts are present.
Installation Instructions
  • Typical Installation: Involves a Kestrel wind turbine, charge controller, diversion resistor, and storage battery.
  • Mounting: Indoor installation only, with sufficient space for cooling.
  • Electrical Wiring: Not polarity sensitive; ensure compatibility with turbine and controller.
  • Securing: Follow safety procedures before maintenance.
Wiring and Cable Sizes
  • Wiring: Ensure secure connections to prevent high temperatures and battery overcharging.
  • Lightning Protection: Proper grounding is crucial for system protection.
Technical Specifications
  • General: High power resistor enclosure for converting excess electrical energy into heat.
  • Resistor Elements: Constructed from high-temperature molded ceramic and copper nickel wire.
Product Specifications
The document details specifications for various diversion resistor models used in wind turbines, including e150/e220i and e300i models with voltage options (12Vdc, 24Vdc, 36Vdc, 48Vdc, 110Vdc) and power ratings (800W, 1200W). Cooling is achieved through natural convection, with a maximum ambient temperature of 40°C and an IP rating of IP23. Cabinet dimensions and mass vary by power rating.
Compliance and Standards
The diversion resistor complies with EMC requirements CIS22 Class B and conforms to standards such as IEC 60204-1, IEC 60038, IEC 60529, and IEC 61000. A declaration of conformity is provided by Eveready Diversified Products (Pty) Ltd.
Troubleshooting
Common issues include high system voltage, improper resistor connections, and overheating. Proper matching of the diversion resistor to the turbine and controller is crucial to avoid malfunctions. Improper disconnection of the diversion resistor can damage the charge controller.
Maintenance
Routine checks should ensure all connections are secure. The diversion resistor is designed for continuous operation and requires no regular part replacement. Cleaning should be done with a soft damp cloth, avoiding solvents.
Warranty Conditions
The product is warranted to be free of defects for 24 months from installation, subject to proper use and maintenance. The warranty covers repair or replacement of defective resistors but excludes damage from extreme winds or other uncontrollable factors. An extended warranty is available for purchase.
Contact Information
Kestrel Wind Turbines can be contacted via phone, email, or their website for further inquiries or feedback.
Customer Feedback
A feedback form is provided for customers to submit inquiries or comments, emphasizing the importance of customer input.
See more

Catalog excerpts

Divert Resistors -1

Divert Resistor Manual Document #: 0601M01 REV : 1.1 Approval: Date: March ‘08 Page 1 of 17 Registration Number 2006/005438/07 VAT Registration Number 4870231406 Tel: +27 (0)41 401 2500 Website: www.kestrelwind.co.za Kestrel Diversion Resistors Type 0601 User Manual Revision 1.0 (03-08)

 Open the catalog to page 1
Divert Resistors -2

Divert Resistor Manual Document #: 0601M01 REV : 1.0 Approval: Date: March ‘08 Page 2 of 17 CONTENTS PAGE 1 Safety Considerations 1.1 Mechanical Safety 3 1.2 Electrical Safety 3 1.3 Installation Hazards 3 1.4 Operational Safety 3 2 Diversion Resistor Overview 2.1 Diversion Resistor Description 4 2.2 Identification and Markings 4 2.3 Applications and uses 5 2.4 Application List 5 3 Diversion Resistor Assembly 3.1 Components Supplied 6 3.2 Components not Supplied 6 3.3 Tools Required 6 3.4 Unpacking 6 4 Installation Instructions 4.1 Typical Installation Example 7 4.2 Mounting the Diversion Resistor...

 Open the catalog to page 2
Divert Resistors -3

Divert Resistor Manual Document #: 0601M01 REV : 1.0 Approval: Date: March ‘08 Page 3 of 17 1 Saffetty Consiiderrattiions 1..1 Mechaniicall Saffetty 1..2 Ellecttrriicall Saffetty 1..3 IInsttallllattiion Hazarrds 1..4 Operrattiionall Saffetty Disclaimer Kestrel Wind Turbines makes every effort to give accurate information in this manual and is in no way liable for any error or omission. The user of this manual assumes full responsibility and risk. We appeal to your common sense to read and apply the safety notes. Consult professional engineers and take advice if you are unsure. 1 SAFETY FIRST...

 Open the catalog to page 3
Divert Resistors -4

Divert Resistor Manual Document #: 0601M01 REV : 1.0 Approval: Date: March ‘08 Page 4 of 17 2 Diiverrsiion Resiisttorr Overrviiew 2..1 Diiverrsiion Resiisttorr Descrriipttiion 2..2 IIdenttiiffiicattiion and Marrkiings 2..3 Applliicattiion and Uses 2 DIVERSION RESISTOR OVERVIEW 2.1 Diversion Resistor Description IMPORTANT: This product is designed for use with Kestrel Charge Controllers that are installed to charge batteries known as Battery-Charging systems. Failure to fit a divert resistor to Kestrel Charge Controllers Type 0102, 0801 and 0401 will cause malfunctions and damage to the controller....

 Open the catalog to page 4
Divert Resistors -5

Divert Resistor Manual Document #: 0601M01 REV : 1.0 Approval: Date: March ‘08 Page 5 of 17 2.3 Applications and Uses Kestrel Diversion Resistors Type 0601are primarily intended for use with Kestrel Charge Controllers connected to Kestrel wind turbines that have been installed to charge batteries. Each application may require specific additional electrical equipment. Consult the manuals supplied with this equipment. 2.4 Application List The following table shows the appropriate diversion resistor that must be used with each Kestrel turbine and charge controller. The electrical current rating...

 Open the catalog to page 5
Divert Resistors -6

Divert Resistor Manual Document #: 0601M01 REV : 1.0 Approval: Date: March ‘08 Page 6 of 17 3 DIVERSION RESISTOR ASSEMBLY 3.1 Components Supplied The following components are supplied: Diversion Resistor assembly (800 or 1200W) User Manual 3.2 Components Not Supplied The following components are necessary to complete an installation: Electrical crimp terminals Wall fixing screws 20mm cable glands 3.3 Tools Required The following hand tools are required for Diversion Resistor installation: Small size electrical screwdriver Medium size electrical screwdriver Wire strippers for electrical connections...

 Open the catalog to page 6
Divert Resistors -7

Divert Resistor Manual Document #: 0601M01 REV : 1.0 Approval: Date: March ‘08 Page 7 of 17 4 INSTALLATION INSTRUCTIONS 4.1 Typical Installation Example A typical battery charging installation is shown below. The system comprises of a Kestrel wind turbine, Kestrel charge controller, Kestrel diversion resistor and storage battery. Note that other electrical equipment will be required to comply with local installation requirements, such as an additional inverter which converts the battery dc power into standard ac power such that common mains powered appliances can be supplied. Consult the relevant...

 Open the catalog to page 7
Divert Resistors -8

Divert Resistor Manual Document #: 0601M01 REV : 1.0 Approval: Date: March ‘08 Page 8 of 17 4.2 Mounting the Diversion Resistor The Kestrel Diversion Resistor Type 0601 is only suitable for indoor installation. The unit must be vertically mounted using the four internal fixing holes provided. Use secure fastening with suitable wall plugs or bolts. Allow a minimum of 200mm (8”) space all around the unit for cooling. It is normal for the voltage limiter to become quite hot at times as it dissipates unwanted energy. Do not place any objects on the top of the enclosure. Make sure that air can freely...

 Open the catalog to page 8
Divert Resistors -9

Divert Resistor Manual Document #: 0601M01 REV : 1.0 Approval: Date: March ‘08 Page 9 of 17 4.3 Electrical Wiring The diversion resistor is not polarity sensitive and can be connected either way round. It is usual to connect the positive terminal on the left. CHECK THAT THE DIVERSION RESISTOR IS THE CORRECT TYPE FOR THE TURBINE AND CHARGE CONTROLLER. PLEASE FOLLOW THE INSTRUCTIONS BELOW ! CONSULT SECTION 5 FOR WIRE SIZE RECOMMENDATIONS The Kestrel charge regulator is provided with one pair of clearly marked terminals for "RESISTOR" at the bottom of the regulator marked R1A and R1B. The diversion...

 Open the catalog to page 9
Divert Resistors -10

Divert Resistor Manual Document #: 0601M01 REV : 1.0 Approval: Date: March ‘08 Page 10 of 17 5 Wiirriing and Cablle Siizes 5..1 Diiverrsiion Resiisttorr Wiirriing 5..2 Liighttniing Prrottecttiion 5 WIRING AND CABLE SIZES 5.1 Diversion Resistor Wiring The following suggestions are made as a guideline. If you are in doubt, consult an electrician. The output wires must be extended as required for the installation. Choose the wire size that is suggested for the size of turbine, electrical current and the distance from the turbine to the charge controller. Good wire connections between the charge...

 Open the catalog to page 10
Divert Resistors -12

Divert Resistor Manual Document #: 0601M01 REV : 1.0 Approval: Date: March ‘08 Page 12 of 17 6.2 DECLARATION OF CONFORMITY Eveready Diversified Products (Pty) Ltd T/A Kestrel Wind Turbines in South Africa declare under our sole responsibility that the product Diversion Resistor Type 0601 To which this declaration relates is in conformity with the following standards IEC 60204-1 Safety of Machinery IEC 60038 IEC Standard Voltages IEC 60529 Degrees of Protection of Enclosures IEC 61000 Electromagnetic Compatibility Date: 25th December 2007 Place: Port Elizabeth South Africa Authorising Signature:...