Safety Considerations
  • Mechanical Safety: Proper handling methods are crucial to avoid injuries during installation and maintenance.
  • Electrical Safety: Avoid working on the system during turbine operation or lightning. Ensure correct wire sizing and ventilation for battery installations.
  • Installation Hazards: Follow installation instructions carefully and check for loose connections.
  • Operational Safety: Be aware of high temperatures during operation and avoid maintenance during windy conditions.
Charge Controller Overview
  • Description: The Kestrel Type 0801 Charge Controller manages power from wind turbines and solar panels to safely charge batteries using electronic shunt control.
  • Identification and Markings: Features a product rating plate and serial number for authenticity.
  • Applications and Uses: Used primarily with Kestrel wind turbines for battery charging.
Charge Controller Assembly
  • Components Supplied: Includes the charge controller assembly.
  • Components Not Supplied: Requires additional items like electrical crimp terminals and wall fixing screws.
  • Tools Required: Necessary tools include screwdrivers and wire strippers.
  • Unpacking: Check parts against the packing slip.
Installation Instructions
  • Typical Installation Example: Describes a setup with a wind turbine, charge controller, divert resistor, battery, and inverter.
  • Mounting the Controller: Specifies indoor vertical mounting with space for cooling.
  • Electrical Wiring: Details the connection process, emphasizing correct polarity and safety precautions.
  • Adjusting the Charging Voltage: Instructions for adjusting the charging voltage for different battery types.
Wiring and Cable Sizing
  • Wind Turbine Wiring: Advises on wire size selection based on turbine size, current, and distance to the charge controller.
  • Battery Wiring: Similar guidelines as turbine wiring, emphasizing correct polarity.
  • Lightning Protection: Recommends direct earthing of the mounting structure.
Technical Specifications

Includes detailed specifications for the charge controller's operation and performance.

Troubleshooting

Provides solutions for common issues encountered during operation.

Maintenance

Outlines regular maintenance procedures to ensure optimal performance.

Warranty Conditions

Details the terms and conditions of the product warranty.

Customer Feedback

Encourages users to provide feedback on the product and its performance.

Additional Information
  • Wiring and Installation: Supply cables should be buried at least 0.5 meters deep in a suitable conduit. Proper grounding is essential for lightning protection.
  • Wire Tables: Wire sizes are calculated for a 3% power loss, with recommendations for different voltages and distances.
  • Battery Considerations: Only deep cycle batteries should be used, with specific charging voltages for Lead Acid, Sealed Gel, and Ni-Cad batteries.
  • Technical Specifications: Designed for telecommunication specifications with a 1000W capability, supporting system voltages of 12, 24, and 48Vdc, with efficiency between 96% and 99%.
  • Troubleshooting: Common issues include polarity reversal and high operating temperatures, with solutions involving checking connections.
  • Maintenance: The charge controller requires no regular part replacement but should be kept clean for proper airflow.
  • Warranty Conditions: The product is warranted for two years against defects in design, material, and workmanship.
  • Contact Information: Kestrel Wind Turbines provides contact details for customer support and inquiries.
See more

Catalog excerpts

Charge Controller-1

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 1 of 21 Registration Number 2006/005438/07 VAT Registration Number 4870231406 Tel: +27 (0)41 401 2500 Website: www.kestrelwind.co.za Kestrel Charge Controller Type 0801 User Manual Revision 1.0 (04-08) For the following models of Type 0801 Charge Controller Type 0801-1000-012 (e300-002-012) 1000W 60A Type 0801-1000-024 (e300-002-024) 1000W 40A Type 0801-1000-048 (e300-002-048) 1000W 25A

 Open the catalog to page 1
Charge Controller-2

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 2 of 21 CONTENTS PAGE 1 Safety Considerations 1.1 Mechanical Safety 3 1.2 Electrical Safety 3 1.3 Installation Hazards 3 1.4 Operational Safety 3 2 Charge Controller Overview 2.1 Charge Controller Description 4 2.2 Identification and Markings 5 2.3 Applications and Uses 5 3 Charge Controller Assembly 3.1 Components Supplied 6 3.2 Components not Supplied 6 3.3 Tools Required 6 3.4 Unpacking 6 4 Installation Instructions 4.1 Typical Installation Example 7 4.2 Mounting the Charge Controller 8 4.3 Electrical Wiring...

 Open the catalog to page 2
Charge Controller-3

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 3 of 21 1 Saffetty Consiiderrattiions 1..1 Mechaniicall Saffetty 1..2 Ellecttrriicall Saffetty 1..3 IInsttallllattiion Hazarrds 1..4 Operrattiionall Saffetty Note: The Charge Controller Type 0801 must be installed with a separate divert resistor. Disclaimer Kestrel Wind Turbines makes every effort to give accurate information in this manual and is in no way liable for any error or omission. The user of this manual assumes full responsibility and risk. We appeal to your common sense to read and apply the safety...

 Open the catalog to page 3
Charge Controller-4

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 4 of 21 2 Charrge Conttrrollllerr Overrviiew 2..1 Charrge Conttrrollllerr Descrriipttiion 2..2 IIdenttiiffiicattiion and Marrkiings 2..3 Applliicattiion and Uses 2 CHARGE CONTROLLER OVERVIEW 2.1 Charge Controller Description IMPORTANT: A suitable divert power resistor must be installed with this product Sustainable/renewable energy sources such as wind turbines and solar panels generate uncontrolled power that must be regulated to facilitate the correct and safe charging of storage batteries. The Kestrel Type...

 Open the catalog to page 4
Charge Controller-5

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 5 of 21 2.2 Identification and Markings On the Charge Controller enclosure is a product rating plate and serial number, if the charge controller does not carry this stamp it does not carry a Kestrel warranty and may not be authentic. *NOTE: Product Rating label example (above) is for format only, specifications do not apply On the front cover of the charge controller are two circuit breakers which are labelled accordingly. Removing the front cover (shown below right) reveals connection labels. 2.3 Applications...

 Open the catalog to page 5
Charge Controller-6

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 6 of 21 3 CHARGE CONTROLLER ASSEMBLY 3.1 Components Supplied The following components are supplied: Charge Controller assembly 3.2 Components Not Supplied The following components are necessary to complete an installation: Electrical crimp terminals Wall fixing screws 20mm cable glands 3.3 Tools Required The following hand tools are required for Charge Controller installation: Small size electrical screwdriver Medium size electrical screwdriver Wire strippers for electrical connections Electrical crimping pliers...

 Open the catalog to page 6
Charge Controller-7

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 7 of 21 4 INSTALLATION INSTRUCTIONS 4.1 Typical Installation Example A typical battery charging installation is shown below. The system comprises a Kestrel wind turbine, Charge Controller, Divert Resistor, battery and an inverter. The inverter is additional and converts the battery dc power into standard ac power such that common mains powered appliances can be supplied. NOTE: The load circuit breaker and inverter are additional equipment and not supplied with the charge controller. The diversion resistor is...

 Open the catalog to page 7
Charge Controller-8

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 8 of 21 4.2 Mounting the Controller The Kestrel Charge Controller Type 0801 is only suitable for indoor installation. The unit must be vertically mounted using the four external fixing holes provided. Use secure fastening with suitable wall plugs or bolts. Allow a minimum of 100mm (4”) space all around the unit for cooling. It is normal for the regulator to become quite hot at times as it dissipates unwanted energy. Do not place any objects on the top of the enclosure. The unit relies on the free passage of...

 Open the catalog to page 8
Charge Controller-9

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 9 of 21 4.3 Electrical Wiring Observe the Polarity at all times. Only connect +VE RED cables to +VE RED terminals and -VE BLACK cables to -VE BLACK terminals. Otherwise, equipment damage may result and any warranty will be invalidated. 9

 Open the catalog to page 9
Charge Controller-10

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 10 of 21 PLEASE FOLLOW THE INSTRUCTIONS BELOW ! CONSULT SECTION 5 FOR WIRE SIZE RECOMMENDATIONS The Charge Controller is provided with three pairs of +VE and -VE clearly marked terminals for "TURBINE" and "BATTERY" and one pair of DIVERT RESISTOR terminals clearly marked R1A and R1B at the bottom of the regulator. The TURBINE BRAKE switch is designated “S1” and the BATTERY CIRCUIT BREAKER is designated “Q1”. The turbine brake switch stops the turbine by creating an electrical short on the turbine input. When...

 Open the catalog to page 10
Charge Controller-11

Charge Controller Manual Document #: 0102M01 REV : 1.2 Approval: Date: March ’08 Page 11 of 21 4.4 Adjusting the Charging Voltage Always switch the turbine brake on (S1 ON) and the battery circuit breaker off (Q1 OFF) before adjusting the charging voltage jumper The Kestrel Charge Controller Type 0801 is suitable for all lead acid batteries whether vented, semi-sealed or sealed and the charging voltage may be adjusted. When the cover is removed, the jumper is visible in the middle of the control board. The charging voltage may be adjusted to the following table. There are five positions for the...

 Open the catalog to page 11

All Eveready Diversified Products catalogs and technical brochures

  1. e400i (3kW)

    2  Pages

  2. e300i (1kW)

    2  Pages

Related Searches
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.