video corpo

EDG-135G
15Pages

{{requestButtons}}

Catalog excerpts

EDG-135G - 1

GAS ENGINE GENERATOR EVERDIGM Corp. Prime Power Rating 50Hz – 135kVA / 108kW Outstanding Features ◈ High Quality EVERDIGM Co. has successful generator set production with strong reputation for quality and durability. ◈ Simple and Easy Operation With centralized controls simplifying generator operation, supervision and operation are made very easy. ◈ Automatic Shutdown The need for supervision is also reduced by the protective shut off devices which guard against emergency like oil pressure drop or cooling water temperature rise. ◈ Environmentally Friendly and Low Cost Operation Environmentally friendly gas engine keeps operation costs very low because there are high efficiency of gas engine. ◈ Easy Installation Installation is easy because no special foundation work is needed and all components are mounted on a common bed. Build the Future ◈ Voltage Regulation Accuracy ±2.5% in steady state condition, speed from –2% to +5%, p.f. from 0.8 to 1. ◈ Adjustable range of generator voltage Voltage variable range is more then ±5% at rated speed, no load. ◈ Waveform distortion (THD) Waveform deviation factor is less then 5% at no load line-toline, reduces risk of over-heating and of interference with sensitive communication equipment. ◈ Frequency Variation of Generator

Open the catalog to page 1
EDG-135G - 2

Alternator MECHANICAL SYSTEM Manufacture Engine model Cylinder, number (Type) Speed rpm Combustion type Prime power ps Compression ratio Aspiration Rotation Doosan Infracore GE08TI 6 (In-line) 1,500 (50Hz) 1,800 (60Hz) Stoichiometric, Premixed and spark ignited 174(50Hz), 204(60Hz) 128(50Hz), 150(60Hz) 8.071 (492.52) 111 (4.37) x 139 (5.47) 10.5 : 1 Turbocharged & Intercooled (water to air) CCW viewed from Flywheel SPECIFICATION Type Voltage Speed(Frequency) rpm(Hz) Phase / Wire Power factor Pole Insulation class Excitation Coupling Bearing Connection Number of leads Degree of protection...

Open the catalog to page 2
EDG-135G - 3

DISPLAY ♦ 3phase voltage/current(Line to Line, Line to Phase) ♦ Frequency / RPM, Power factor, kW ♦ Battery voltage, Cooling water temperature, Lub. Oil pressure. LIGHT FAULT HEAVY FAULT PRE-ALARM, LED ♦ Speed sensor fault ♦ No charging ♦ Low cooling water temperature ♦ Battery voltage over/under ♦ Over load ENGINE SHUTDOWN AND MAIN CIRCUIT BREAKER TRIP ♦ Cooling water temp. high ♦ Low oil pressure ♦ Over speed ♦ Fail to start ♦ Emergency stop ♦ Over voltage MAIN CIRCUIT BREAKER TRIP ♦ Over current ♦ Under voltage APPLICATION ♦ Peak Saving, Base load operation with main power ♦ Parallel...

Open the catalog to page 3
EDG-135G - 4

GAS ENGINE GENERATOR EVERDIGM Corp. Prime Power Rating 50Hz - 175kVA / 140kW Outstanding Features ◈ High Quality EVERDIGM Co. has successful generator set production with strong reputation for quality and durability. ◈ Simple and Easy Operation With centralized controls simplifying generator operation, supervision and operation are made very easy. ◈ Automatic Shutdown The need for supervision is also reduced by the protective shut off devices which guard against emergency like oil pressure drop or cooling water temperature rise. ◈ Environmentally Friendly and Low Cost Operation...

Open the catalog to page 4
EDG-135G - 5

Alternator MECHANICAL SYSTEM Manufacture Engine model Cylinder, number (Type) Speed rpm Combustion type Prime power ps Compression ratio Aspiration Rotation Doosan Infracore GE12TI 6 (In-line) 1,500 (50Hz) 1,800 (60Hz) Stoichiometric, Premixed and spark ignited 238(50Hz), 272(60Hz) 175(50Hz), 200(60Hz) 11.051 (674.5) 123 (4.84) x 155 (6.1) 10.5 : 1 Turbocharged & Intercooled (water to air) CCW viewed from Flywheel SPECIFICATION Type Voltage Speed(Frequency) rpm(Hz) Phase / Wire Power factor Pole Insulation class Excitation Coupling Bearing Connection Number of leads Degree of protection...

Open the catalog to page 5
EDG-135G - 6

DISPLAY ♦ 3phase voltage/current(Line to Line, Line to Phase) ♦ kWH ♦ Battery voltage, Cooling water temperature, Lub. Oil pressure. LIGHT FAULT PRE-ALARM, LED ♦ Speed sensor fault ♦ No charging ♦ Low cooling water temperature ♦ Battery voltage over/under ♦ Over load ♦ Frequency / RPM, Power factor, kW ♦ Running hour HEAVY FAULT ENGINE SHUTDOWN AND MAIN CIRCUIT BREAKER TRIP ♦ Cooling water temp. high ♦ Low oil pressure ♦ Over speed ♦ Fail to start ♦ Emergency stop ♦ Over voltage MAIN CIRCUIT BREAKER TRIP ♦ Over current ♦ Under voltage APPLICATION ♦ Peak Saving, Base load operation with main...

Open the catalog to page 6
EDG-135G - 7

GAS ENGINE GENERATOR EVERDIGM Corp. Prime Power Rating 50Hz - 235kVA / 188kW Outstanding Features ◈ High Quality EVERDIGM Co. has successful generator set production with strong reputation for quality and durability. ◈ Simple and Easy Operation With centralized controls simplifying generator operation, supervision and operation are made very easy. ◈ Automatic Shutdown The need for supervision is also reduced by the protective shut off devices which guard against emergency like oil pressure drop or cooling water temperature rise. ◈ Environmentally Friendly and Low Cost Operation...

Open the catalog to page 7
EDG-135G - 8

Gas Engine Doosan Infracore GV158TI 8 (V-line) 1,500 (50Hz) 1,800 (60Hz) Stoichiometric, Premixed and spark ignited 313(50Hz), 367(60Hz) 230(50Hz), 270(60Hz) 14.618 (892.05) 128 (5.04) x 142 (5.59) 10.5 : 1 Turbocharged & Intercooled (water to air) CCW viewed from Flywheel MECHANICAL SYSTEM Manufacture Engine model Cylinder, number (Type) Speed rpm Combustion type Prime power ps Compression ratio Aspiration Rotation SPECIFICATION Type Voltage Speed(Frequency) rpm(Hz) Phase / Wire Power factor Pole Insulation class Excitation Coupling Bearing Connection Number of leads Degree of protection...

Open the catalog to page 8
EDG-135G - 9

DISPLAY ♦ 3phase voltage/current(Line to Line, Line to Phase) ♦ Frequency / RPM, Power factor, kW ♦ Battery voltage, Cooling water temperature, Lub. Oil pressure. LIGHT FAULT HEAVY FAULT PRE-ALARM, LED ♦ Speed sensor fault ♦ No charging ♦ Low cooling water temperature ♦ Battery voltage over/under ♦ Over load ENGINE SHUTDOWN AND MAIN CIRCUIT BREAKER TRIP ♦ Cooling water temp. high ♦ Low oil pressure ♦ Over speed ♦ Fail to start ♦ Emergency stop ♦ Over voltage MAIN CIRCUIT BREAKER TRIP ♦ Over current ♦ Under voltage APPLICATION ♦ Peak Saving, Base load operation with main power ♦ Parallel...

Open the catalog to page 9

All Everdigm catalogs and technical brochures

  1. T500

    2 Pages

  2. EHB100

    2 Pages

  3. Generator Set

    14 Pages

  4. G-Series

    12 Pages

  5. ROCKY8

    2 Pages

  6. EHB100

    2 Pages

  7. Lorry Crane

    6 Pages

  8. ECP59CX-5

    2 Pages

  9. ECP63CS-5

    2 Pages

  10. T500

    2 Pages

  11. ECD SERIES

    4 Pages

  12. EHB06NA

    1 Pages

  13. ECP56CX

    2 Pages

  14. ECP50CX-5

    4 Pages

  15. ECP53CS-5

    4 Pages

  16. ECP56CS-5

    4 Pages

  17. ECP53CX-5

    4 Pages

  18. ED-F series

    12 Pages

  19. ECP32RS

    4 Pages

  20. ECP30CX-5

    4 Pages

  21. ECP28ZX

    4 Pages

  22. ECP24ZX

    4 Pages

  23. ECP21ZX

    4 Pages

  24. everdigm

    2 Pages

  25. ERL53

    1 Pages

  26. EAP37

    1 Pages

  27. EAP48

    1 Pages

  28. Generator Set

    12 Pages

  29. ECR12

    1 Pages

  30. ETP570

    1 Pages

  31. ETP970

    1 Pages

  32. ETP1012

    1 Pages

  33. ETP1015

    1 Pages

  34. ETP1017

    1 Pages

  35. ETP7200

    1 Pages

  36. ED150F-10

    12 Pages

  37. ED740L-32

    6 Pages

  38. ED580L-24

    6 Pages

  39. KH200L-16

    6 Pages

  40. ED300L-16

    8 Pages

Archived catalogs