Catalog excerpts
Eurovacuum EVC Series Dry Running Claw Vacuum Pump
Open the catalog to page 1Eurovacuum EVC Series Dry Running Claw Vacuum Pumps Eurovacuum Company is offering its various products to meet industrial vacuum needs. Eurovacuum Company is founded in 2006, with over 30 year experiences in the vacuum Industry its founders have been putting their best efforts continuously to produce high quality Dry Running Claw Vacuum Pumps, with diverse range of capacity for use in printing, pick & place, packaging, CNC Routing, vacuum lifting, Central systems and General vacuum or other industrial application. Advantages to the User • High pumping speed • The pumping chamber is oil...
Open the catalog to page 2Contents Eurovacuum EVC Series Dry running Claw Vacuum Pump • • • • • • • EVC-0060 EVC-0100 EVC-0150 EVC-0250 EVC-0300 EVC-0400 EVC-0500 4 6 8 10 12 14 16 Accessories for Vacuum Pump 18 Central vacuum systems 22
Open the catalog to page 3TYPE EVC-0060 TYPE EVC-0060 Technical Data Nominal displacement Ultimate pressure max. Pressure continuous running Motor power Nominal speed Noise level Oil filling gear housing Weight Admissible ambient temp. Connection Inlet Outlet m3/h mbar mbar kW rpm dB(A) ltr kg °C NPT NPT Ordering Information Three phase motor 400V, 50Hz (IEC) 400V, 60Hz (IEC) Other Voltages/Frequencies Vacuum regulate valve Exhaust damper Gasket set Maintenance kit Pump module Inlet dust filter, paper cartridge 50 Hz 60 60 100 to 1000 1,1 1450 66 0,5 108 5 to 40 1¼” 1¼” 60 Hz 72 60 100 to 1000 1,5 1750 70 0,5 113 5...
Open the catalog to page 5TYPE EVC-0100 TYPE EVC-0100 Technical Data Nominal displacement Ultimate pressure max. Pressure continuous running Motor power Nominal speed Noise level Oil filling gear housing Weight Admissible ambient temp. Connection Inlet Outlet m3/h mbar mbar kW rpm dB(A) ltr kg °C NPT NPT Ordering Information Three phase motor 400V, 50Hz (IEC) 400V, 60Hz (IEC) Other Voltages/Frequencies Vacuum regulate valve Exhaust damper Gasket set Maintenance kit Pump module Inlet dust filter, paper cartridge 50 Hz 100 50 150 to 1000 2,2 2850 78 0,5 108 5 to 40 1½” 1½” 60 Hz 120 50 150 to 1000 3,0 3450 82 0,5 113...
Open the catalog to page 7TYPE EVC-0150 TYPE EVC-0150 Technical Data Nominal displacement Ultimate pressure max. Pressure continuous running Motor power Nominal speed Noise level Oil filling gear housing Weight Admissible ambient temp. Connection Inlet Outlet m3/h mbar mbar kW rpm dB(A) ltr kg °C NPT NPT Ordering Information Three phase motor 400V, 50Hz (IEC) 400V, 60Hz (IEC) Other Voltages/Frequencies Vacuum regulate valve Exhaust damper Gasket set Maintenance kit Pump module Inlet dust filter, paper cartridge 50 Hz 150 50 100 to 1000 3,0 2850 79 0,6 125 5 to 40 1½” 1½” 60 Hz 180 50 100 to 1000 3,6 3450 82 0,6 125...
Open the catalog to page 9TYPE EVC-0250 TYPE EVC-0250 Technical Data Nominal displacement Ultimate pressure max. Pressure continuous running Motor power Nominal speed Noise level Oil filling gear housing Weight Admissible ambient temp. Connection Inlet Outlet m3/h mbar mbar kW rpm dB(A) ltr kg °C NPT NPT Ordering Information Three phase motor 400V, 50Hz (IEC) 400V, 60Hz (IEC) Other Voltages/Frequencies Vacuum regulate valve Exhaust damper Gasket set Maintenance kit Pump module Inlet dust filter, paper cartridge 50 Hz 250 50 150 to 1000 4,0 2850 78 0,75 203 5 to 40 2” 2” 60 Hz 280 50 150 to 1000 5,5 3450 82 0,75 220...
Open the catalog to page 11TYPE EVC-0300 TYPE EVC-0300 Technical Data Nominal displacement Ultimate pressure max. Pressure continuous running Motor power Nominal speed Noise level Oil filling gear housing Weight Admissible ambient temp. Connection Inlet Outlet m3/h mbar mbar kW rpm dB(A) ltr kg °C NPT NPT Ordering Information Three phase motor 400V, 50Hz (IEC) 400V, 60Hz (IEC) Other Voltages/Frequencies Vacuum regulate valve Exhaust damper Gasket set Maintenance kit Pump module Inlet dust filter, paper cartridge 50 Hz 300 50 200 to 1000 5,5 2850 79 0,75 263 5 to 40 2” 2” 60 Hz 360 50 200 to 1000 6,5 3450 83 0,75 263...
Open the catalog to page 13Pumping speed curve
Open the catalog to page 14TYPE EVC-0400 TYPE EVC-0400 Technical Data Nominal displacement Ultimate pressure max. Pressure continuous running Motor power Nominal speed Noise level Oil filling gear housing Weight Admissible ambient temp. Connection Inlet Outlet m3/h mbar mbar kW rpm dB(A) ltr kg °C NPT NPT Ordering Information Three phase motor 400V, 50Hz (IEC) 400V, 60Hz (IEC) Other Voltages/Frequencies Vacuum regulate valve Exhaust damper Gasket set Maintenance kit Pump module Inlet dust filter, paper cartridge 50 Hz 385 50 250 to 1000 7,5 2850 82 0,75 330 5 to 40 3” 3” 60 Hz 460 50 250 to 1000 9,0 3450 84 0,75 330...
Open the catalog to page 15TYPE EVC-0500 TYPE EVC-0500 Technical Data Nominal displacement Ultimate pressure max. Pressure continuous running Motor power Nominal speed Noise level Oil filling gear housing Weight Admissible ambient temp. Connection Inlet Outlet m3/h mbar mbar kW rpm dB(A) ltr kg °C NPT NPT Ordering Information Three phase motor 400V, 50Hz (IEC) 400V, 60Hz (IEC) Other Voltages/Frequencies Vacuum regulate valve Exhaust damper Gasket set Maintenance kit Pump module Inlet dust filter, paper cartridge 50 Hz 500 50 250 to 1000 9,0 2850 82 0,75 370 5 to 40 3” 3” 60 Hz 600 50 250 to 1000 11,0 3450 84 0,75 390...
Open the catalog to page 17EVC Series dust filters Dust filters for the inlet side of the EVC-Series vacuum pumps These dust filters can be mounted on the intake side of the EVC-Series vacuum pumps to protect the pump against: dust, powders, chips, etc. The filters consists of a steel housing with a lit and quick locking clamps. Quick changing of cartridges is possible and the filters have a high separation ratio. The housings are suitable to be fitted with four different kind of filters: Paper cartridge Polyester cartridge Metal cartridge Separates particles down to 5 µm. Specially suitable for dry processes. We use...
Open the catalog to page 21EVC Central Vacuum Systems EVC Central Vacuum Systems for use in factories and hospitals Double system, 2 pumps Double systems are commonly used in the Industry and offer the advantage of supplying a continues vacuum more economical then a number of small vacuum units. It also compensates large vacuum variations in the number of vacuum consumers. Triple system, 3 pumps Triple systems are commonly used in hospitals and offer the same advantages as the double system. The third pump also offers an extra safety factor for when one of the pumps is switched off by an error or for service purpose....
Open the catalog to page 22All Eurovacuum B.V. catalogs and technical brochures
-
Pernicka 700H
3 Pages
-
T-Guard
3 Pages
-
LDS3000
5 Pages
-
UL1000
4 Pages
-
Protec P3000(XL)
5 Pages
-
Condenstraps
1 Pages
-
Large Quantity Dust Filters
2 Pages
-
Dust Filters
1 Pages
-
Medical Filters