RASI 200-1

EiUK Multi-Purpose Flue Gas Analyser • Check all combustion parameters • Measure Differential Temperature • Measure Differential Pressure • Perform let-by, stabilization and tightness tests • Perform CO build-up tests • Perform smoke tests • 5 years Extended Warranty Tested to BS EN 50379 Service is what matters to most of us! Only 2 days turnaround

 Open the catalog to page 1
RASI 200-2

KIT’s selection Basic KIT RASI 200 Analyser 300x8 mm flue gas probe Rechargeable battery/Carger Rubber Sleeve with magnet Calibration Certficate Software, USB cable ABS carrying case • • • • • • • Fast IRDA Infrared Printer 2 x Pipe Clamp on probes Differential pressure hose KIT Gas Leak Detector BS 6967 Appliance Probe KIT Gas Pressure Controller Standard KIT Advanced KIT • • • • • • • • • • • • • • • • • • CPA1 KIT OIL KIT • • • • • • • • • • • • • • • • • • • • • • • • Oil commissioning KIT Smoke Pump Oil Filter RASI200 Basic KIT RASI200 CPA1 KIT RASI200 Advanced KIT RASI200 Standard KIT

 Open the catalog to page 2
RASI 200-3

Features RASI 200 02, CO, C02, Ratio, Excess Air, Efficiencies (Net, Gross Condensing) Temperature Flue, Air and Differential NOX measurement • • Optional Draught Pressure and Differential Pressure Multi Fuel Use on OIL/GAS/WOOD fired burner Automatic T Flow/T Return Automatic timed tightness test (IGE/UP/1B) Automatic Let By test ( IGE/UP/1B) with timing settable CO room built up (15 minutes LOG and CO (Max)) BS 6967 • • • • • • • Service plan Eurotron Service & Calibration Department is dedicated to offering you a first class, efficient and competitively priced service. Our team, supported...

 Open the catalog to page 3
RASI 200-4

Specifications Range Accuracy Resolution Measured Gases O2 measurement 0 to 21 % Vol CO measurement 0 to 4000 ppm NO (NOx) measurement (Optional) 0 to 5000 ppm ±0.2 Vol % abs ± 10 ppm or 5 % rdg ( <4000 ppm) 10 % of rdg > 4000 ppm ± 5 ppm or 5 % rdg ( <1000 ppm) 10 % of rdg > 1000 ppm 0.1 % Vol % abs 1 ppm 1 ppm Temperature and Pressure Temperature measurement Direct and diferential -40 to 600 Deg ± 1 °C (-40 to 200 °C) ± 1 % of rdg ( 200 to 1200 °C 0.1 °C Draft measurement ± 40 hPa/mbar ±0.02 hPa or ±1 % of rdg 0.1 hPa/mbar Pressure measurement ( gauge, negative and differential) ± 300 hPa(mBar)...

 Open the catalog to page 4

All Eurotron Instruments UK ltd catalogs and technical brochures

  1. RASI700 BIO

    3  Pages

  2. rasi 800

    7  Pages

  3. ETB

    2  Pages

  4. PGS60

    4  Pages

  5. PGS 7 1V

    2  Pages

  6. P100

    1  Page

  7. calog loop

    1  Page

  8. Rasi 200-I

    3  Pages

  9. plb

    5  Pages

  10. PTB

    6  Pages

  11. PGS-7

    2  Pages

  12. EiUK PC4

    1  Page

  13. EiUK LCC 100

    1  Page

  14. EiUK LPC 300

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.