Catalog excerpts
calibration. The new range have been introduced to the market to offer a cost effective solutions to our customer whilst meeting a wide range of application EiUK ETB 140 offers 3-in-1 solution The unit cover temperature range from - 55 °C from Tamb to 140 °C. The standard liquid insert convert your dry block in a portable liquid bath, with adjustable speed agitator. When used as liquid bath, TCS 140 enhanced features offers the same specification of a laboratory liquid bath. This calibrator features • Wide range from -55 to 140 °C • Excellent stability to 0.02 °C • Excellent Uniformity to 0.02 °C • Reading accuracy ±0.15 °C • Use as DryBlock, Liquid bath or Infrared source The EiUK ETB series of field dry block calibrator consist of there separate models for calibrating temperature sensors, loop and switches in a temperature range between -48 and 1200 °C. These self-contained units are portable, flexible and are suitable for both field and laboratory temperature Parameter Temperature range eurotron “Excellence in measurements” EiUK ETB 650, cover a wide range from 35 to 650 °C over a well dimension of 35 x 160 mm to suit multiple probe testing at the same time. The new Eurotron controller technology ensure high stability and performance. Features • Range from 35 to 650 °C • Well to well uniformity to 008 °C • Stability 0.02 • Use as DryBlock, or Infrared source EiUK ETB1200 cover a high temperature range, but still do not compromise in any technical specification. The advance temperature controller ensure high stability at higher temperature. This calibrator features • Wide range from 150 to 1200 °C • Excellent stability to 0.15 °C • Customised removable insert inserts • Use as DryBlock, or Infrared source Absolute stability (dry Block) ±0.035 °C @ 140 °C Absolute stability (liquid bath) ±0.02 °C @ 140 °C Radial uniformity (dry Block) ±0.02 °C @ 140 °C Radial uniformity (liquid bath) ±0.004 °C @ 140 °C Temperature units Heating Time Cooling Time Well Size Block Depth Well Depth Standard insert INS-B Physical dimension Sensor type Power supply Thermoscopes, RTD’s, temperature switches-General application CAPABILITIES Features Range Liquid bath Black body source insert Customised inserts Removable inserts Fast heating/cooling Serial interface RS232 ATCS compatible Documenting (offline procedure) Automatic Temperature Calibration System (ATCS) Save time and effort by performing on-line calibration procedure. The ATCS system is an high accuracy modular scanner for T/C’s, RTD’s pressure switches and temperature transmitters controlled by the CalPman advanced version software package. The system is able to handle up to 32 temperature sensors simultaneously. Learn more on how ATCS can improve efficency in your calibration routine and saving money. Infrared Thermometers Odd shaped sensor, short sensors, laboratory accuracy, glass thermometers Liquid insert for ETB140 The liquid insert supplied as standard for the TCS 140 model ensure maximum flexibility and enhanced the performance of this powerful temperature calibrator. The liquid insert is the perfect solution when you need laboratory accuracy in the field, or when you calibrate short, square or odd-shaped sensors. The liquid bath eliminate the source of error related to immersion depth and fit, which you can find using common dry block calibrator. The fluid media offer an excellent thermal contact and uniformity. Eurotron Instruments always suggest the use of an External reference thermometer which compensates for temperature gradient and loading error. This give greater accuracy and traceability, meeting the requirements of ISO 9000 or other quality standard. Typical applications are: • Short, odd-shaped and square sensors • Bimetal and glass thermometer • Enhanced stability and uniformity
Open the catalog to page 1eurotron “Excellence in measurements” Blank insert 2 x 4.5 mm, 2 x 6.4 mm. 1 x 9.5 mm, 1 x 8 mm (included as standard) Custom insert. Contact us for holes availability Stirred liquid bath insert, include container, magnetic stirrer (included as standard) Black body target insert Surface sensor insert kit (include insert and angle PRT) INS-B INS-C INS-L INS-IR Customised sizes ETB 650 INSERTS Ordering code ETB650-INS-A ETB650-INS-B ETB650-INS-C ETB140-INS-IR INS-A blank Blank insert 2 x 4.5 mm, 2 x 6.4 mm. 1 x 9.5 mm, 1 x 8 mm (included as standard) Custom insert. Contact us for holes...
Open the catalog to page 2All Eurotron Instruments UK ltd catalogs and technical brochures
-
RASI 300 Flue Gas Analyser
3 Pages
-
RASI 300C Flue Gas Analyser
12 Pages
-
SWG100 BIOcompact
2 Pages
-
RASI700 BIO
3 Pages
-
rasi 800
7 Pages
-
PGS60
4 Pages
-
PGS 7 1V
2 Pages
-
P100
1 Pages
-
P100 Digital Pressure Gauge
3 Pages
-
calog loop
1 Pages
-
RASI 200
4 Pages
-
Rasi 200-I
3 Pages
-
plb
5 Pages
-
PTB
6 Pages
-
Pressure Comparators
1 Pages
-
PGS-7
2 Pages
-
EiUK PC4
1 Pages
-
EiUK LCC 100
1 Pages
-
EiUK LPC 300
2 Pages