The Raptor System: Raptor HV Datasheet Description The Raptor-HV, the High Voltage slave, is an optional product that extends the Raptor’s applications to tests that require the use of high AC voltage, up to 2 KV. This product works in combination with a Raptor Master and is visually similar to it. The Raptor HV connects to the master unit via the Expansion Port, from where it also takes the necessary power. The Raptor HV is a pluggable high voltage peripheral that takes advantage of all the valuable features in the Raptor Master including the electronically controlled switching amplifier, DSP based intelligence and a robust communication and device synchronization system. Naturally the HV’s control is fully integrated in the master’s console. Power voltage generated by the master at the expansion port is raised by the HV up to two user selectable ranges, 1kV and 2kV, and the output is measured in current, voltage and phase angle to provide adequate injection control and application’s feedback. Voltages and currents can be measured with very high precision to allow for a wide variety of applications. In order to comply with international safety requirements, the Raptor HV’s package includes an internal buzzer that signalizes the high voltage output activation and two connectors for an optional rotting warning lamp and an optional mushroom type emergency breaker. The internal buzzer can be disabled from the Raptor’s console. Other outstanding feature is the capacity to inject in frequencies different from the mains frequency, enhancing its electrical testing capacity. The use of any of the Raptor C-XX systems with the Raptor HV provides a world-wide unique system, which combines both high current and high voltage injection, with the suitable power, for the main maintenance and commissioning test applications in substations and switchgear. It is an innovative and advanced substation test system that replaces the need for multiple test sets. The Raptor HV weighs only 28 kg, and it has the same small and compact size than the rest of Raptor units, with wheels and folding handle, that provides a lower transportation cost and a reduction of manpower needs. Features • Two user selectable output ranges: 0-1000 VAC and 0-2000 VAC. • Powered from the Raptor Master via expansion port. • Controlled from the common Raptor Master’s user interface. • Integrated test voltage and current measurement. • Supported by additional Test Templates. • Audible safety buzzer. • Detachable rotary warning lamp and Emergency stop button. • Outstanding Raptor style portability. Applications • CT, VT and PT withstand voltage tests. • CT and VT excitation current measurement, Knee Point. • VT and PT ratio measurement. • Polarity test in VT’s secondary winding. • Testing voltage sensors and converters. • Step &
Open the catalog to page 1The Raptor System: Raptor HV Formula Innovation RAPTOR HV Raptor HV connected to a Raptor Master unit powered by 240 Vac, 50 Hz. HIGH VOLTAGE POWER OUTPUT (@240Vac, 50Hz) DRDERING INFDRMATIDN SYSTEM CONFIGURATION RAPTOR C-05 RAPTOR C-15 RAPTOR C-25 RAPTOR C-35 RAPTOR C-XX + RAPTOR HV 1 x Raptor-HH + 1 x Raptor-MS 1 x Raptor-HH + 1 x Raptor-MS + 1 x Raptor-SL Open circuit resolution Output frequency 1 Vac 20-400 Hz (Power reduction applied when outside the 50-60 Hz range) MEASUREMENT (INTERNAL) @(10..100)% of the range / 50-60Hz Secondary current (internal) Ranges Resolution Frequency...
Open the catalog to page 213 Pages
7 Pages
7 Pages
8 Pages
2 Pages
1 Page
1 Page
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
4 Pages
4 Pages
2 Pages
8 Pages
8 Pages
16 Pages
3 Pages
40 Pages
8 Pages
25 Pages