Contents Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03 . HS00 - Adhesive tape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06 HS01 - Washer mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 07 HS02 - Reinforced washer mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08 HS03 - Ring mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 09 HS05 - Contact block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 HS10 - Weld pad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 HS11 - Weld pad (45° angle) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Surface thermistors HS12 - Weld pad (Plug-in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 HS20 - Angle / Plug-in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 . HS21 - Angle / Plug-in (Clamp) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 HS30 - Bayonet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 HS31 - Bayonet with reduced tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 HS33 - Bayonet (Reverse) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HS34 - Bayonet with clamp (90° angle) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 HS41 - Pipe-Clamp (Type 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 HS42 - Pipe-Clamp (Type 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 HS43 - Pipe-Clamp (Type 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 HS50 - Handheld . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 HS60 - Spring loaded magnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 HH25 - Contact block (Surface mount) with terminal head. . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 HR20 - Nozzle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 8 chemin des Grandes Combes 69360 Ternay, France +33 472 669 234 contact@eurosensors.eu www.eurosensors.eu

Open the catalog to page 1
20 - Surface thermistors - 2

Surface thermistors - Technical Information What are the characteristics of surface thermistors? Surface thermistors detect surface temperature. The most important issue in surface temperature measurement is to keep measurement errors as small as possible. This is achieved by an appropriate design of the measuring head, so that only very little heat is extracted from the measuring point and the measurement error is negligible. The perfectly adapted geometry increases the contact surface. At the same time, the low thermal mass of the measuring head ensures that comparatively fast response...

Open the catalog to page 2
20 - Surface thermistors - 3

Surface thermistors - Technical Information What are the two types of thermistor? NTC (Negative Temperature Coefficient) are made of a conductive material based on transition metals and are used to measure temperatures up to 300 °C. An RTD (Resistance Temperature Detector) is a type of sensor used to measure temperature. RTDs are used for accurate, stable and reliable temperature measurements in generally high temperature ranges. PTC (Positive Temperature Coefficient) are made of a conductive material based on polymer or ceramic or ceramic material and are used to measure temperatures up to...

Open the catalog to page 3
20 - Surface thermistors - 4

Surface thermistors - Technical Information Types of thermistors The β beta value A thermistor’s “β” value, or beta value, is an indication of the shape of the curve representing the relationship between resistance and temperature of an NTC thermistor. Calculating the beta value is a vital step in the component selection process as it gives the characteristic at a given temperature vs the resistance for a specific application. Beta value Thermistor connectors Due to the lack of standardization in RTD connectors, our company takes pride in its ability to produce a wide range of RTD...

Open the catalog to page 4
20 - Surface thermistors - 5

HS00 – Surface thermistors Adhesive tape *Adhesive tape material Fiberglass/PTFE Ordering information Additional: Operating temperature (min/max): Other: ( NTC / PTC , T° ( min / max ) , ß value, tolerance ) 2. Wiring configuration (number of wires) 2 3. Cable prolongation: Teflon (260°C) How to order? Choose the desired characteristics of your sensor by marking the checkboxes and by filling up the text. You can provide sketches, images, personal notes, special requirements or any important data. For additional questions and assistance, feel free to contact us. 8 chemin des Grandes Combes...

Open the catalog to page 5
20 - Surface thermistors - 6

HS01 – Surface thermistors Washer mount *Washer mount material Tinned copper Ordering information Additional: Operating temperature (min/max): Other: ( NTC / PTC , T° ( min / max ) , ß value, tolerance ) 2. Wiring configuration (number of wires) 2 3. Cable prolongation: Teflon (260°C) How to order? Choose the desired characteristics of your sensor by marking the checkboxes and by filling up the text. You can provide sketches, images, personal notes, special requirements or any important data. For additional questions and assistance, feel free to contact us. 8 chemin des Grandes Combes 69360...

Open the catalog to page 6

All EuroSensors catalogs and technical brochures