Applications
This single-use respirator is designed to protect against solid and liquid particles, including oil-based mists. It is suitable for use in various industries such as farming, insulation, woodworking, and grain production. It offers protection against hazards like wood dust, aluminium, gypsum, graphite, and welding fumes.

Technical Specifications
The respirator is lightweight at 16g and features a multi-layered filter medium with electrostatic charge. It is ergonomically shaped for comfort, with adjustable head straps and a nose clip for a secure fit. The product is color-coded for easy identification, individually packed with instructions, and conforms to the EN149:2001+A1:2009 standard. It is non-allergenic and provides a protection factor of 10 x A.P.F. and 12 x N.P.F.

Usage
The RESPAIR 2 respirator can be used in environments with particulates as defined by H.S.E. document EH40, offering protection of 10 x A.P.F. and 12 x N.P.F. For higher protection, FFP3 respirators are recommended.

Unique Filter Material
The filter material offers low breathing resistance and exceeds EN149:2001+A1:2009 performance requirements.

Ergonomic Design
The design allows for freedom of speech, easy fitting, minimal leakage, and compatibility with other protective equipment.

Fitting Instructions
1. Place the bottom headband over the neck.
2. Position the mask under the chin and over the nose, securing the top headband.
3. Adjust side clips for comfort and mold the nose clip securely.
4. Perform a fit check by exhaling vigorously to ensure no leaks.

Instructions for Use
Suitable for solid and liquid particulates, not for gases or low oxygen environments. Do not use if contaminants are unknown or dangerous. Replace after 8 hours or if breathing becomes difficult. Store between +5º C and +32º C at less than 80% RH.

Face Fit Testing
Face fit testing is crucial to ensure the respirator's effectiveness. Misuse, such as interference from facial hair, can compromise safety. The COSHH ACoP mandates testing for tight-fitting respirators. Our team offers on-site testing services using a nebuliser to ensure a proper seal.
See more

Catalog excerpts

RESPAIR P2 FOLD FLAT DISPOSABLE RESPIRATOR-1

TECHNICAL DATA SHEET SINGLE USE RESPIRATOR - PROTECTS AGAINST SOLID & LIQUID PARTICLES INCLUDING OIL BASED MISTS APPLICATIONS Farming, Insulation Contractors, Woodworking, Remedial work, Grain / Flour production, etc. Protects against Wood Dust, Aluminium, Gypsum, Graphite, Magnesium Oxide, Platinum, Coal, Lead, Chrome, Welding Fumes, and many other general hazards. RESPAIR P2 FOLD FLAT DISPOSABLE RESPIRATOR MADE IN THE UK TECHNICAL SPECIFICATION • Lightweight - 16g • Multi layered filter medium combining electrostatic charge • Ergonomically shaped for comfort and ease of use • Adjustable head straps to provide individual fit • Adjustable nose clip to ensure good seal around nose • Colour coded for ease of identification • Individually packed complete with instructions for use • Conforms to the European approved standard EN149:2001+A1:2009 • Non-allergenic EN149:2001+A1:2009 FFP2 (NR) provides a protection factor of 10 x A.P.F. (Assigned Protection Factor) and 12 x N.P.F. (Nominal Protection Factor) USAGE RESPAIR 2 can be used in atmospheres containing particulates as defined in the current H.S.E. document EH40 to provide a level of protection of 10 x A.P.F. and 12 x N.P.F. If there is a requirement for a higher level of protection the next level is FFP3 providing a protection of 20 x A.P.F, and 50 x N.P.F. UNIQUE FILTER MATERIAL The unique filter material provides an extremely low breathing resistance, and far exceeds the performance required by EN149:2001+A1:2009. ERGONOMICALLY DESIGNED Allows freedom of speech, an easy fit minimising leakage providing a high level of protection and comfort plus complete compatibility with all other forms of protective equipment giving an especially clear field of vision. Respair, Unit B, Carterton Industrial Estate, Carterton, Oxfordshire. OX18 3EZ Call: +44 (0) 1993 840606 Email: [email protected] Visit: ww

 Open the catalog to page 1
RESPAIR P2 FOLD FLAT DISPOSABLE RESPIRATOR-2

TECHNICAL DATA SHEET FITTING INSTRUCTIONS 1. Hold the mask firmly and place the bottom headband over the head to the nape of the neck. 2. Place the mask under the chin, then over the nose, putting the top head band over the crown of the head. 3. Ensure a good fit by pulling back the side clips on to the face and adjust for comfort. 4. Ensure that the nose clip is moulded around the nose securely. FIT CHECK Check the fit of the mask by covering with both hands and exhale vigorously. Any leaks around the face seal must be eliminated before entering contaminated area. 3. Suitable for use against...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.