RESPAIR® MODEL X P3V

RESPAIR® MODEL X P3V

RESPAIR® MODEL X P3V

Product catalog summary
Ergonomic Design and Compatibility: The RESPAIR Model X P3V mask is ergonomically designed to allow freedom of movement and ease of communication. It provides a high level of protection and comfort, with compatibility with other protective equipment, ensuring a clear field of vision.
Instructions for Use: The mask must be fitted according to the supplied instructions. It is crucial to select the correct mask type for the specific work environment. Professional advice should be sought if there is any doubt about the mask type required.
Limitations of Use: The mask offers protection only if fitted correctly. It should be discarded if removed in a contaminated area, if breathing difficulties occur due to clogging, or if the mask is damaged. Allergic reactions may occur in susceptible individuals, necessitating removal and medical advice.
Applications and Usage: Suitable for use in hospitals, healthcare, pharmaceutical industry, crime scenes, clean rooms, construction, woodworking, car refinishing, iron and steel manufacturing, mining, quarries, and the nuclear industry. It provides protection against particulates as defined in HSE document EH40, with a protection factor of 20 x UK A.P.F. and 50 x N.P.F.
Technical Specifications: The mask is lightweight at 18g, filters 99% of airborne particulates, and features a multi-layered filter medium with electrostatic charge. It is ergonomically shaped for comfort, with adjustable head straps for a secure fit, and is individually packed with instructions.
Unique Filter Material: The filter material offers low breathing resistance and exceeds EN149:2001+A1:2009 performance requirements.
Face Fit Testing: Face fit testing is mandatory for tight-fitting RPE in the workplace and must be conducted initially and at regular intervals. Respair offers both qualitative and quantitative fit testing services, with training available for companies to conduct their own fit testing.
Fitting Instructions: The mask should be carefully unwrapped, placed over the head and under the chin, with the nose band molded to the nose shape without pinching. Straps should be adjusted for a secure fit.
Training and Services: Respair provides training on qualitative and quantitative fit testing methods, including hands-on experience and certification upon completion. This training can be conducted on-site and is designed to be efficient and cost-effective for companies using RPE regularly.
See more

Catalog excerpts

RESPAIR® MODEL X P3V-1

DISPOSABLE RESPIRATORS TECHNICAL DATA SHEET RESPAIR ® MODEL X P3V Protects against very fine particles and liquid aerosols, including very fine dusts, fumes, fibres, mists, radioactive dusts, bacteria and viruses. Fitted with exhalation valve for easier breathing. APPLICATIONS: Hospitals & healthcare, pharmaceutical industry, crime scenes, clean room environments, construction, woodworking, car refinishing, iron & steel manufacturing, mining & quarries, nuclear industry. PROTECTION: 50 X N.P.F (EN529) Applications & Usage Ergonomically Designed Hospitals & healthcare, pharmaceutical industry, crime scenes, clean room environments, construction, woodworking, car refinishing, iron & steel manufacturing, mining & quarries, nuclear industry. RESPAIR MODEL X P3V can be used in atmospheres containing particulates as defined in the current HSE document EH40 to provide a level of protection of 20 x UK A.P.F. and 50 x N.P.F. Allows freedom of movement and easier communication, an easy fit minimising leakage providing a high level of protection and comfort plus complete compatibility with all other forms of protective equipment giving an especially clear field of vision. Technical Specification Mask must be fitted in accordance with the instructions supplied. Care must be taken to ensure that the correct mask type is selected for the work to be carried out. If in doubt as to the type of mask required seek professional advice. Lightweight - 18g Filters 99% of airborne particulates Multi-layered filter medium combining electrostatic charge Ergonomically shaped for comfort and ease of use Adjustable head straps to provide individual fit Individually packed complete with instructions for use EN149 FFP3 provides a protection factor of 20 x UK A.P.F. (Assigned Protection Factor) and 50 x N.P.F. (Nominal Protection Factor) Unique Filter Material The unique filter material provides an extremely low breathing resistance, and far exceeds the performance required by EN149:2001+A1:2009. Limitations of Use Protection will only be offered if the mask is fitted correctly. The mask must be discarded and replaced if it is a). Removed whilst in the contaminated area, b). Breathing difficulties due to clogging are experienced or, c). The mask becomes damaged. The mask, when in contact with the skin may cause allergic reactions to susceptible individuals. If this occurs leave the hazard area, remove mask and seek medical advice. Respair® Technology Centre, Carterton Unit B, Carterton Industrial Estate, Carterton, Oxfordshire. OX18 3EZ Copyright © 2020-2021. JSP Ltd. All Righ

 Open the catalog to page 1
RESPAIR® MODEL X P3V-2

Fitting Instructions 1. Carefully unwrap mask. 2. Place the bottom headband over the head to the nape of the neck. 3. Place the mask under the chin, then over the nose. 4. Pull the top head band over the crown of the head. 5. Using both hands mould the nose band to the shape of your nose, do not pinch the nose band as this could create a break in the seal. 6. Adjust the straps to ensure a comfortable secure fit. Face Fit Testing As part of our service we offer qualitative test kits, provide qualitative & quantitative face fit testing, and can train individuals to become competent fit testers....

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.