RESPAIR® MODEL X P2

RESPAIR® MODEL X P2

RESPAIR® MODEL X P2

Product catalog summary
Ergonomic Design and Compatibility
The mask is designed to allow freedom of movement and ease of communication while minimizing leakage. It provides high protection and comfort, and is compatible with other protective equipment, ensuring a clear field of vision.

Instructions for Use
The mask must be fitted according to the supplied instructions. It is crucial to select the correct mask type for the specific work environment. Professional advice should be sought if there is any doubt.

Limitations of Use
Protection is only effective if the mask is correctly fitted. The mask should be replaced if removed in a contaminated area, if breathing becomes difficult due to clogging, or if the mask is damaged. Allergic reactions may occur in some individuals, necessitating removal and medical advice.

Applications & Usage
The mask is suitable for environments requiring protection for both the wearer and the environment, such as agriculture and cleaning. It filters particulates as defined in HSE document EH40, providing protection levels of 10 x UK A.P.F. and 12 x N.P.F.

Technical Specification
The mask is lightweight (12.5g) and filters 94% of airborne particulates. It features a multi-layered filter medium with electrostatic charge, ergonomic shape, adjustable head straps, and is individually packed with instructions. It meets EN149 FFP2 standards.

Unique Filter Material
The filter material offers low breathing resistance and exceeds EN149:2001+A1:2009 performance requirements.

Face Fit Testing
Face fit testing is mandatory for tight-fitting RPE and must be conducted initially and at regular intervals. Respair offers both qualitative and quantitative fit testing services, and can train individuals to conduct fit testing within their company.

Fitting Instructions
1. Unwrap the mask.
2. Place the bottom headband over the neck.
3. Position the mask under the chin and over the nose.
4. Pull the top headband over the head.
5. Mold the nose band without pinching.
6. Adjust straps for a secure fit.

Training and Services
Respair provides on-site training for fit testing methods, including qualitative taste test (Bitrex) and quantitative ambient particle counting (APC). Training covers legislation, RPE information, and fit testing principles, with participants receiving a completion certificate.
See more

Catalog excerpts

RESPAIR® MODEL X P2-1

DISPOSABLE RESPIRATORS TECHNICAL DATA SHEET RESPAIR ® MODEL X P2 Protects against fine particles and liquid aerosols, including fine dusts, fumes, fibres, and mists. Non-valved to ensure exhaled air is filtered. APPLICATIONS: Agriculture, cleaning & janitorial. PROTECTION: 12 X N.P.F (EN529) Applications & Usage Ergonomically Designed Where protection is required to protect the wearer, and also the product/ environment this bi directional filter works both ways. Agriculture, cleaning & janitorial. RESPAIR MODEL X P2 can be used in atmospheres containing particulates as defined in the current HSE document EH40 to provide a level of protection of 10 x UK A.P.F. and 12 x N.P.F. Allows freedom of movement and easier communication, an easy fit minimising leakage providing a high level of protection and comfort plus complete compatibility with all other forms of protective equipment giving an especially clear field of vision. Technical Specification Mask must be fitted in accordance with the instructions supplied. Care must be taken to ensure that the correct mask type is selected for the work to be carried out. If in doubt as to the type of mask required seek professional advice. • Lightweight - 12.5g • Filters 94% of airborne particulates • Multi-layered filter medium combining electrostatic charge • Ergonomically shaped for comfort and ease of use • Adjustable head straps to provide individual fit • Individually packed complete with instructions for use • Directional filter protects the wearer and the wearers Bi environment EN149 FFP2 provides a protection factor of 10 x UK A.P.F. (Assigned Protection Factor) and 12 x N.P.F. (Nominal Protection Factor) Unique Filter Material Limitations of Use Protection will only be offered if the mask is fitted correctly. The mask must be discarded and replaced if it is a). Removed whilst in the contaminated area, b). Breathing difficulties due to clogging are experienced or, c). The mask becomes damaged. The mask, when in contact with the skin may cause allergic reactions to susceptible individuals. If this occurs leave the hazard area, remove mask and seek medical advice. The unique filter material provides an extremely low breathing resistance, and far exceeds the performance required by EN149:2001+A1:2009. Respair® Technology Centre, Carterton Unit B, Carterton Industrial Estate, Carterton, Oxfordshire. OX18 3EZ Copyright © 2020-2021. JSP Ltd. All Ri

 Open the catalog to page 1
RESPAIR® MODEL X P2-2

Fitting Instructions 1. Carefully unwrap mask. 2. Place the bottom headband over the head to the nape of the neck. 3. Place the mask under the chin, then over the nose. 4. Pull the top head band over the crown of the head. 5. Using both hands mould the nose band to the shape of your nose, do not pinch the nose band as this could create a break in the seal. 6. Adjust the straps to ensure a comfortable secure fit. Face Fit Testing As part of our service we offer qualitative test kits, provide qualitative & quantitative face fit testing, and can train individuals to become competent fit testers....

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.