EUREKONE FLOWMETER - 1

EUREKONE FLOWMETER A perfect solution for industry’s difficult flow measurement problems *As per PED 97/23/EC Against Specific Requirement Only EUREKA INDUSTRIAL EQUIPMENTS PVT. LTD. REGD. & SALES OFFICE : 17-20, 1st Floor, Royal Chambers, Paud Road, Pune 411 038. Maharashtra, India. Tel : +91-20-25443079, 25451314 Fax : +91-20-25441323 Email : sales@eurekaflow.com / eurekapnmail@vsnl.net : J-501, MIDC, Pimpri, Pune 411018 Tel : +91-20-30681732 to 55 FAX : +91-20-30681731 Email : eurekamail@vsnl.net / works@eurekaflow.com MUMBAI OFFICE : Office no 116, Growmore Tower, First Floor, Plot no. 5, Sector no. 2, Kharghar, Navi Mumbai 410210. Mobile : +91-9322598274 AUTHO. SERVICE CENTRE : Eureka Hightech, 281/1, Plot No. 38, Kasar Amboli, Tal. - Mulshi, Pune 412108 Tel : 020-22922170

Open the catalog to page 1
EUREKONE FLOWMETER - 2

The EUREKONE FLOWMETER is a new differential pressure flowmeter device that accurately measures flow of various fluids over wider flow range than any other conventional differential pressure flowmeter such as venturies, orifice plates etc. The basic principle is Bernoulli's theorem for the conservation of energy in fluid flow through a pipe. The divergent shape of the cone sensor centered in the line, reshapes the velocity profile to create an improved profile. The configuration of a typical EUREKONE FLOWMETER is showing fig. A/B. The pressure difference between the static line pressure and...

Open the catalog to page 2
EUREKONE FLOWMETER - 3

SECONDARY INSTRUMENTATION TheEUREKONEFLOWMETER works with any standard Differential Pressure Gauge, D.P.Transmitters,Manometers, etc. The EUREKONE FLOWMETER can be incorporated into an existing system without having to invest in new instrumentation. The EUREKONE FLOWMETER Combined with D. P. Transmitter and flow computer forms a complete system to meet stringent applications as shown in FIG.3 & 4 TEMPERATURE TRANSMITTER PRESSURE TRANSMITTER EUREKONE FLOWMETER PROCESS CONTROL OUTPUT FLOW COMPUTER DIFFERENTIAL PRESSURE TRANSMITTER PRINTER RECORDER FIG. 3 - TYPICAL SECONDARY INSTRUMENTATION...

Open the catalog to page 3
EUREKONE FLOWMETER - 4

INSTALLATION REQUIREMENTS The velocity profile is reshaped by the cone sensor & hence there is no need for long upstream straight pipe lengths. Typically installation piping requirements are about 3 Diameter Upstream & 5 Diameters Downstream for all type of pipe fittings present upstream. The EUREKONE FLOWMETER may be installed in either horizontal or vertical piping. The EUREKONE FLOWMETER finds application in the measurement of flow of Water, Steam, Air, Nitrogen, Hydrogen, Coke oven gas, Propane, Argon, Neon, Exhaut Gases & many more fluids. Monitoring air / water / steam consumption....

Open the catalog to page 4
EUREKONE FLOWMETER - 5

SMART D.P. TRANSITTER PROCESS INDICATING TOTALISER (MICROPROCESSED BASED) DOWNSTREAM SIDE RETRANSMISSION O/P 4-20 mA AUX. SUPPLY 24VDC@30mA INPUT 4-20mA AGAINST REQUEST FOR CALIBRATED VERSION EUREKONE FLOWMETER FRONT VIEW FLOW INDICATING TOTALISER UPSTREAM SIDE REAR VIEW EUREKONE WITH DIRECT DPT MOUNTING CONDENSING POTS NIPPLES 1/2"NPT (M) UNIONS 1/2"NB SOCKET WELD ELBOWS (1/2"NB) UNIONS 1/2"NB SOCKET WELD ELBOWS (1/2"NB) UNIONS 1/2"NB SOCKET WELD NIPPLES 1/2"NPT (M) GLOBE VALVES 1/2"NPT (F) COMPRESSION FITTING OW FL OR TO ICAT IND DIFF. PRESSURE TRANSMITTER TYPICAL INSTALLATION DRG. STEAM...

Open the catalog to page 5
EUREKONE FLOWMETER - 6

EUREKONE FLOWMETER is most superior compared to other flowmeters. Following comparison proves the superiority of EUREKONE. EUREKONE FLOWMETER ORIFICE PLATE A) High installation cost due to very long straight pipe runs requirements. B) Same accuracy with dirty particles content fluids B) Subject to abrasion and loss of accuracy C) Not reliable for wet gas condensate measurment D) High pressure loss E) High turn down ratio F) Requires routine maintenance EUREKONE FLOWMETER A) Very high cost C) Wide range of applications including high temp. C) Not suitable for high temp. fluids. D) Long term...