Catalog excerpts
Transponder-coded safety systems CEM with guard locking for process protection More than safety.
Open the catalog to page 1Transponder-coded safety systems CEM CEM safety systems are modern interlocking devices for the protection of persons, machines and processes. Based on transponder technology, they combine a safety door monitor and a solenoid in a single system. CEM products are used in safeguarding movable guards for reliable detection of doors in closed position and guard locking for process protection. n Layout The CEM systems essentially consist of the following components: Actuator with coded transponder and movable anchor plate Guard locking solenoid Read coil Evaluation electronics n Simple function...
Open the catalog to page 2n Actuator The actuator’s spring-mounted anchor plate can be deflected up to an angle of ±4°. This allows the actuator to adjust itself independently to the surface of the CEM guard locking solenoid when the door is closed. n Simple compliance with standards Transponder coding ensures maximum safety. The requirements of relevant standards can be met with only a single CEM system. Irrespective of whether category 4 / PL e according to EN ISO 13849-1 must be achieved or whether the requirements in EN ISO 14119 must be met – you’re always on the safe side with the CEM. n Overview of features...
Open the catalog to page 3Transponder-coded safety systems CEM n Different coding levels U nicode: Each CEM actuator features transponder coding that significantly surpasses the requirement in the EN ISO 14119 standard for a type 4 switch with a high coding level. The actuator’s transponder code is unambiguously assigned to the safety switch by means of a teach-in operation. This effectively prevents the guard from being bypassed using an identical actuator. The requirement in the standard for effective protection against tampering is also met in this way. If necessary, a new actuator can be taught in at any time. M...
Open the catalog to page 4n EM-A: System with external evaluation C External evaluation of signals in the control cabinet The guard locking solenoid with the read coil is accommodated in a housing (read head). The actuator’s transponder signals are read by the read coil and forwarded to a CES evaluation unit in the control cabinet (external evaluation). Up to four CEM-A read heads can be connected to a CES evaluation unit. n EM-C60: Variable system with internal evaluation C Internal evaluation of signals in an individually selected switch The system consists only of an actuator and a guard locking solenoid. The...
Open the catalog to page 5CEM-A – Systems with external evaluation External evaluation of signals in the control cabinet With external evaluation of the transponder signals, the evaluation electronics are accommodated in a separate housing in the control cabinet. Up to four CEM-A devices or additional read heads from EUCHNER can be connected to the CES evaluation unit and evaluated. The wiring work is minimal, because each read head can be connected to the evaluation unit via only two flexible wires. n CES-AZ evaluation units CES evaluation units combine transponder evaluation with a safety relay in a single device....
Open the catalog to page 6Optional versions: ► Adjustable adhesive force of 70 N / 110 N / 150 N with programming adapter ► Integrated permanent magnet (30 N) ► With hard-wired connecting cables ■ CEM-A read heads Read head CEM-A-LE05 ► Locking force 650 N ► With and without remanence ► Connection via two M8 plug connectors ► LED indicator in M8 plug connector ► Small design ► Robust metal housing ► Nickel-plated surface Read head CEM-A-LH10 ► Locking force 1,000 N ► With and without remanence ► Connection via two M8 plug connectors ► LED indicator in M8 plug connector ► Connection for external LED indicator ►...
Open the catalog to page 7CEM-C60 – Variable systems with internal Internal evaluation of signals in an individually selected switch This system offers guard locking for process protection in a modular design. It consists of a CEM actuator and a CEM-C60 guard locking solenoid that prevents safety doors from opening unintentionally. The guard locking solenoid is combined with a safety switch for reliable detection of the door position. The safety switch with integrated read coil and evaluation electronics can be selected as required and is mounted on the guard locking solenoid. The CEM-C60 can be combined with the...
Open the catalog to page 8Safe SPS Safe SPS Safe SPS Safety relay Safety relay Safety relay n Using safety switches in the AR / BR system family CES-AZ CES-AZ CES-AZ CES-AZ CES-AZ CES-AZ CES-AZ CES-AZ CES-AZ CES-AZ CES-AZ CES-AZ Evaluation unit Evaluation unit Evaluation unit - CES-AR oror -- CES-AR or CES-AR - BRBR/ IO-Link / / IO-Link -- BRIO-Link Gateway Gateway Gateway Safe SPS Safe SPS Safe SPS Safety relay Safety relay Safety relay Using safety switches in the AP / BP systemSicherheitsfamily SicherheitsSicherheitsSicherheitsSicherheitsSicherheitsSicherheitsSicherheits here SPS Sichere SPS Sichere SPS Sichere...
Open the catalog to page 9CEM-C40 – Safety switch with internal Internal evaluation of signals in the safety switch With internal evaluation, the evaluation electronics and read coil are accommodated in the same housing (safety switch). The switches feature pulsed safety outputs (semiconductor, OSSD) to detect short circuits in the connecting cables. The outputs on the safety switch can be connected to decentral peripheral devices or directly to safe control systems. On the activation of the guard locking, the device checks whether the locking force is at least 400 N. If the locking force is greater than 400 N, the...
Open the catalog to page 10CEM-C40 in detail Degree of protection IP65 / IP67 ideally suited for industrial use Fastening option in three directions for flexible mounting Immediate diagnostic function by means of LED display, monitoring outputs and a diagnostics monitoring output Locking force measurement when solenoid is activated. If the force is > 400 N, a status signal is transmitted to the control system. Can be connected in series Dirt resistant with up to 20 CEM-AR-C40 devices treamlined design S Locking force 600 N Nickel-plated solenoid surface and anchor plate resist abrasion and corrosion Adjustable...
Open the catalog to page 11All EUCHNER GmbH + Co. KG catalogs and technical brochures
-
Electronic-Key-System EKS2
6 Pages
-
Product Guide
20 Pages
-
2023 Electronic-Key-System EKS
60 Pages
-
Industry 4.0
16 Pages
-
EKS with touch panel
12 Pages
-
News 2023
6 Pages
-
Safe key system CKS2
10 Pages
-
Enabling Switches ZS
92 Pages
-
About EUCHNER
34 Pages
-
Transponder-coded safety switches
160 Pages
-
MGBS
52 Pages
-
MGB2
80 Pages
-
Multifunctional Gate Box MGB
5 Pages
-
Multifunctional Gate Box
133 Pages
-
Product Overview Automation
8 Pages
-
Product Overview ManMachine
6 Pages
-
AC-DP-04-SA
2 Pages
-
Safety Switches with Plastic Housing
172 Pages
-
Safety switch CTP‑BI
2 Pages
-
Safety Switches with Metal Housing
220 Pages
-
EKS with USB port
2 Pages
-
Proven Systems - Proven Safe
6 Pages
-
Multiple Limit Switches
36 Pages
-
Position Switches
56 Pages
-
Safety switch CTP-Extended
2 Pages
-
Safety Switches NQ/TQ
6 Pages
-
Joystick Switches
28 Pages
-
EKS Light
8 Pages
-
Safety Relays ESM
32 Pages
-
Electronic-Key-System
24 Pages