Catalog excerpts

MODULAR DESIGN, EASY TO PROGRAM THE SMALL SAFE CONTROL SYSTEM MSC
Open the catalog to page 1
THE SMALL SAFE CONTROL SYSTEM MSC The small control system MSC is the solution for the logic behind your safety system. Individually configured for your machine, it can be used to implement highly diverse safety engineering applications. You can select the right modules to meet the requirements for your installation, paying only for the functions you actually need. Protection using an MSC guarantees maximum safety according to the applicable standards. GREAT USABILITY The device software and hardware are designed for great usability during setup, operation and maintenance work. In addition...
Open the catalog to page 2
FLEXIBLE – EFFICIENT – MAXIMALLY SAFE FAST SETUP T he intuitive EUCHNER Safety Designer software enables fast configuration, clear programming and detailed documentation of the MSC system. INTEGRATION INTO EXISTING BUS SYSTEMS Products from the MSC range can connect the MSC to all common fieldbuses, allowing it to communicate with the higher-level control system. SAVES SPACE IN THE CONTROL CABINET T hanks to the compact housing, even extensive safety functions can be implemented in the smallest of spaces. Special communication modules can interconnect different modules across separate...
Open the catalog to page 3
SAFETY SYSTEM MSC IN USE Diverse safety switchgear can be connected and monitored with the small safe control system MSC. A large selection of expansion modules helps the MSC system fulfill diverse requirements. MSC – THE SAFETY CONTROL SYSTEM FOR Electromechanical safety switches with and without guard locking Transponder-coded safety switches with and without guard locking Emergency stop devices Pushbuttons Safety light curtains and light grids Enabling switches Encoders and proximity switches Pressure-sensitive mats Position switches and multiple limit switches Joystick switches, and...
Open the catalog to page 4
The base unit is the foundation for every MSC system, and it can be expanded with up to 14 expansion modules. MSC EXPANSION OPTIONS Safe inputs Safe outputs High-current safety outputs Programmable monitoring outputs Fieldbus interface Modules for decentralized control system design Rotary and linear speed monitoring Safety relays
Open the catalog to page 5
OVERVIEW OF MSC BASE UNITS Selecting the right base unit forms the foundation for your MSC system. In the maximum expansion stage, up to 128 inputs, 30 dual-channel safety outputs and 48 monitoring outputs can be monitored with the expansion modules using a single small control system. Features of the MSC-CB-S safe inputs and 4 test outputs 8 For connecting commonly used safety engineering sensors dual-channel safe semiconductor outputs 2 Meet the strictest safety requirements and are suitable for single-channel applications connections for flexible use as a monitoring output or control...
Open the catalog to page 6
PROGRAMMING SOFTWARE „EUCHNER SAFETY DESIGNER“ The EUCHNER Safety Designer software can be used to configure, program and document the MSC safety system. It supports rapid setup with simple operation via the graphical user interface, diagnostic options and project report creation. User-friendly interface for simple, intuitive operation Troubleshooting support by real-time depiction of inputs and outputs Simple depiction of even complex functions using extensive function blocks Trouble-free setup by integrated simulation function Various access levels and passwords protect against tampering...
Open the catalog to page 7
OUR PRODUCTS FOR YOUR SAFETY DOOR DETECTION Transponder-coded safety switches without guard locking CES-C04 / CES-C07 Magnetically coded safety switches without guard locking CMS Electromechanical safety switches without guard locking NM / NP / GP / NZ GUARD LOCKING Transponder-coded safety switches with guard locking CTS / CTM / CTP / CTA / CET Electromechanical safety switches with guard locking TP / STP / STA / STM Safety switches with integrated mounting magnet CEM-C40 / CEM-C60 DOOR LOCKING SYSTEMS MGB / MGB2 / MGBS LIGHT GRIDS / LIGHT CURTAINS LCA EMERGENCY STOP DEVICES ES / RPS...
Open the catalog to page 8All EUCHNER GmbH + Co. KG catalogs and technical brochures
-
EUCHNER Safety Services
24 Pages
-
News
6 Pages
-
IO-Link Safety
4 Pages
-
Logistics
3 Pages
-
Safety Relays ESM
32 Pages
-
Product Overview Automation
8 Pages
-
Electronic-Key-System EKS2
6 Pages
-
Product Guide
20 Pages
-
2023 Electronic-Key-System EKS
60 Pages
-
Industry 4.0
16 Pages
-
EKS with touch panel
12 Pages
-
Safe key system CKS2
10 Pages
-
Enabling Switches ZS
92 Pages
-
About EUCHNER
34 Pages
-
Transponder-coded safety switches
160 Pages
-
MGBS
52 Pages
-
Multifunctional Gate Box MGB
5 Pages
-
Multifunctional Gate Box
133 Pages
-
Product Overview ManMachine
6 Pages
-
AC-DP-04-SA
2 Pages
-
Safety Switches with Plastic Housing
172 Pages
-
Safety switch CTP‑BI
2 Pages
-
Safety Switches with Metal Housing
220 Pages
-
EKS with USB port
2 Pages
-
Proven Systems - Proven Safe
6 Pages
-
Multiple Limit Switches
36 Pages
-
Position Switches
56 Pages
-
Safety switch CTP-Extended
2 Pages
-
Safety Switches NQ/TQ
6 Pages
-
Joystick Switches
28 Pages
-
EKS Light
8 Pages
-
Electronic-Key-System
24 Pages