Safe key system CKS2
10Pages

{{requestButtons}}

Catalog excerpts

Safe key system CKS2 - 1

Safe is safe – lockout and starting with a single system Safe key system CKS2

Open the catalog to page 1
Safe key system CKS2 - 2

THE SAFE KEY SYSTEM CKS2 MANY OPTIONS WITH A SINGLE BASE DEVICE Starting sequences in different installation areas I dentical locking safe key system Simple authorization assignment for starting specific process sequences in different installation areas Manual mode for service, setup, etc. Material loading Safe lockout system Stopping the installation to access a dangerous area. The installation cannot be started without a key. Maintenance and service Material loading Benefits for you: No mechanical wear F lexible combination with EUCHNER guard locking devices S afe restart lockout up to...

Open the catalog to page 2
Safe key system CKS2 - 3

ARE YOU PLANNING A SPECIFIC PROJECT? Talk to us. We would gladly help you analyze your application and plan your custom CKS2 concept. Starting a defined sequence Unique locking safe key system Simple authorization assignment for starting a defined process sequence Manual mode Maintenance Benefits for you: No need for complex programming Uncomplicated key management Starting a defined sequence by several operators Authorization system for several operators Authorization system for several keys with the same key code and different key identification Formation of operator groups User data can...

Open the catalog to page 3
Safe key system CKS2 - 4

THE SAFE KEY SYSTEM CKS2 In combination with highly coded, transponder-based keys, the key adapter CKS2 forms a safe system that meets the highest safety requirements for machine and installation lockout and starting. Thanks to the integrated evaluation electronics, the compact CKS2 system can solve many tasks for you. n Simple operation When the key is inserted into the key adapter, the data on the key are read and checked for validity. If the key is recognized as valid, the safety outputs switch. Keys are taught-in directly on the key adapter, without complex programming. n Absolute...

Open the catalog to page 4
Safe key system CKS2 - 5

ALSO AS SUBMODULE MSM-CKS2 The new CKS2 submodule with innovative functions considerably expands the applications for the door locking system MGB2. Here too, all applications from lockout systems and key transfer system to authorization systems are possible. The system can be linked to PROFINET / PROFIsafe or EtherCAT / EtherCAT FSoE using the bus module MBM. n Modular expansion possible Depending on the version, the submodule is available for various connections in the MGB2 world. More than 1,000 different keys can be used thanks to the proven transponder technology and the high coding...

Open the catalog to page 5
Safe key system CKS2 - 6

CKS2 as authorization system Application examples T he key is inserted to access the installation. A ll authorized keys can be used to access the installation. D ifferent operating modes according to key identification are possible on the control panel inside the installation. Example: n he green key can be used to stop or start the T machine and open the flaps. n he blue key can be used to operate the machine T in manual mode and open the flaps. Benefits Simple authorization assignment without program ming thanks to different key identification O ne key can be taught-in and used on several...

Open the catalog to page 6
Safe key system CKS2 - 7

CKS2 as lockout system Application examples T he installation can be started only when the key is inserted. 1. he machine is stopped and the key is withdrawn for T safe access to the installation. Only then can the door be opened. 2. he door is closed after the work in the installation T interior is compete. The safety switch locks the door only when the key is inserted. The installation runs in automatic mode when a key is not inserted. 1. The machine cannot be stopped until a valid key is inserted. The key must be withdrawn to access the installation safely; the door is opened. 2. The...

Open the catalog to page 7
Safe key system CKS2 - 8

CKS2 as key transfer system Application examples Application T he installation can be started only when the key is inserted. 1. he machine is stopped and the key is withdrawn for T safe access to the installation. Only then can the door be opened. 2. he installation interior can be accessed. The safety T door is closed from the inside and locked. 3. he key is inserted at the machine inside the installation. T Only a manual mode can be started. Benefits T he safety outputs are controlled via the control system. A main switch is not needed O ne key can be taught-in and used on several key...

Open the catalog to page 8
Safe key system CKS2 - 9

CKS2 – many functions in a single system Application examples Application   The safety door of each transport aisle is secured by a   guard locking device MGB2 Modular with MSM-CKS2. No key is inserted during automatic operation. 1. o stop the installation in the respective aisle, the asT signed key is inserted and a pushbutton is pressed. 2. hey key is withdrawn, and the door can be opened to T access the aisle. 3. fter the aisle is accessed, the door is closed from the A inside. The same key is inserted into a second key adapter in the interior. Pressing a pushbutton on an extension...

Open the catalog to page 9
Safe key system CKS2 - 10

OUR PRODUCTS FOR YOUR SAFETY SAFE DOOR DETECTION Transponder-coded safety switches without guard locking CES-C04 / CES-C07 Magnetically coded safety switches without guard locking CMS Electromechanical safety switches without guard locking NM / NP / GP / NZ SAFE GUARD LOCKING Transponder-coded safety switches with guard locking CTS / CTM / CTP / CTA / CET Electromechanical safety switches with guard locking TP / STP / STA / STM Safety switches with integrated mounting magnet CEM-C40 / CEM-C60 DOOR LOCKING SYSTEMS MGB / MGBS / MGB2 CLASSIC MGB2 MODULAR (MGB2 PROFINET / MGB2 EtherCAT) ACCESS...

Open the catalog to page 10

All EUCHNER GmbH + Co. KG catalogs and technical brochures

  1. Product Guide

    20 Pages

  2. Industry 4.0

    16 Pages

  3. News 2023

    6 Pages

  4. About EUCHNER

    34 Pages

  5. MGBS

    52 Pages

  6. MGB2

    80 Pages

  7. AC-DP-04-SA

    2 Pages

  8. EKS Light

    8 Pages

Archived catalogs