Multifunctional Gate Box MGBS Slimline More than safety.
Open the catalog to page 1Internationally successful – the EUCHNER company EUCHNER GmbH + Co. KG is a world-leading company in the area of industrial safety technology. EUCHNER has been developing and producing high-quality switching systems for mechanical and systems engineering for more than 60 years. The medium-sized family-operated company based in Leinfelden, Germany, employs Headquarters in Leinfelden-Echterdingen around 800 people around the world. 18 subsidiaries and other sales partners in Germany and abroad work for our international success on the market. Quality and innovation – the EUCHNER products A...
Open the catalog to page 2Multifunctional Gate Box MGBS General The slimline safety door protection device MGBS System components at a glance Example for the combination of the MGBS MGBS sets Sets MGBS Individual MGBS modules Locking modules MGBS-P-L.-… Interlocking modules MGBS-P-I-… Handle modules MGBS-H-… Inner door handle AE-R-S1 Escape releases MGB-E-… Subject to technical modifications; no responsibility is accepted for the accuracy of this information 163691‑03
Open the catalog to page 3The slimline safety door protection device MGBS Transponder-coded safety switch, door handle and end stop in one Space-saving design ■ Handle module for intuitive operation ■ ■ Multifunctional Gate Box MGBS This is the ideal solution wherever a slimline switch housing is advantageous, such as on safety fence corner posts. Concealed mounting holes in the handle module and other modules provide excellent protection against tampering. A lockout mechanism is included in the handle module. This prevents the installation from starting, e.g. during maintenance and cleaning work. A simple plug...
Open the catalog to page 4System components at a glance Locking module MGBS – guard locking for the protection of persons and processes The MGBS locking module is available in different versions for process protection guard locking or personnel protection guard locking. It can be mounted on left- or right-hinged doors and on sliding doors. The system is optionally available with an emergency stop device and with controls and indicators. The resulting MGBS is a slimline safety door protection device with the properties of an MGB. Individual MGBS module Without escape release With escape release Interlocking module...
Open the catalog to page 5Example for the combination of the MGBS Handle module MGBS-H with door handle 157543 (see page 22) Locking module MGBS-P with emergency stop, two illuminated pushbuttons and plug connector M23 159171 (see page 14) Subject to technical modifications; no responsibility is accepted for the accuracy of this information 163691‑03‑03
Open the catalog to page 6Subject to technical modifications; no responsibility is accepted for the accuracy of this information 163691‑03‑03/20
Open the catalog to page 7MGBS »Maximum safety in the smallest possible space.« ► Suitable for tight spaces, e.g. for corner solutions ► Several functions in one solution: door handle, switch, door stop ► Optionally with emergency stop, controls and indicators ► Optionally with escape release ► Category 4 / PL e according to EN ISO 13849-1 8 Subject to technical modifications; no responsibility is accepted for the accuracy of this information 163691-03-03/20
Open the catalog to page 8Locking module Inner door handle With interlocking without guard locking With guard locking Handle module Interlocking module Handle module Escape release Subject to technical modifications; no responsibility is accepted for the accuracy of this information 163691‑03‑03/20
Open the catalog to page 9Locking Modules MGBS Locking modules MGBS-P-L.-AP-... f Locking module for the protection of persons or processes (order handle module separately) f Optionally with control elements, emergency stop and escape release f Door stop can be changed to right/left f Category 4 / PL e for the evaluation of all safety functions | Details Available coding options f Unicode evaluation Guard locking types L1 Closed-circuit current principle Guard locking by spring force. Release by applying voltage to the guard locking solenoid. L2 Open-circuit current principle Guard locking by solenoid force....
Open the catalog to page 10Door stop (factory setting) Escape release For wiring diagram see page 12 MGBS-P-L.-AP-…-SII-… with 2 plug connectors M12 Order no./item MGBS-P‑L1 Closed-circuit current principle * The color of the pushbuttons can be selected using the lens set included. ❚ Dimension drawing Door stop right with plug connector M12 min. 1 max. 6 With escape release Extensions included Auxiliary release Locking screw With 2 plug connectors M12 Subject to technical modifications; no responsibility is accepted for the accuracy of this information
Open the catalog to page 11Subject to technical modifications; no responsibility is accepted for the accuracy of this information 163691-03-03/20
Open the catalog to page 12Subject to technical modifications; no responsibility is accepted for the accuracy of this information 163691‑03‑03/20
Open the catalog to page 13Locking Modules MGBS Locking modules MGBS-P-L.-AR-... f Locking module for the protection of persons or processes (order handle module separately) f Optionally with control elements, emergency stop and escape release f Door stop can be changed to right/left f Category 4 / PL e for the evaluation of all safety functions | Details Available coding options f Unicode evaluation Guard locking types L1 Closed-circuit current principle Guard locking by spring force. Release by applying voltage to the guard locking solenoid. L2 Open-circuit current principle Guard locking by solenoid force....
Open the catalog to page 14❚ Dimension drawing Door stop right < 90 > With escape release LEDs Emergency stop device (S1) 266 Locking screw Auxiliary release Pushbutton 2 illuminated (S2 / H2) Extensions included Subject to technical modifications; no responsibility is accepted for the accuracy of this information 163691‑03‑03/2
Open the catalog to page 15Locking Modules MGBS M23 Subject to technical modifications; no responsibility is accepted for the accuracy of this information 163691-03-03/20
Open the catalog to page 16Subject to technical modifications; no responsibility is accepted for the accuracy of this information 163691‑03‑03/20
Open the catalog to page 17All EUCHNER GmbH + Co. KG catalogs and technical brochures
-
EUCHNER Safety Services
24 Pages
-
Electronic-Key-System EKS2
3 Pages
-
Product Guide
20 Pages
-
Electronic-Key-System EKS
60 Pages
-
Electronic-Key-System EKS
60 Pages
-
Industry 4.0
16 Pages
-
EKS with touch panel
12 Pages
-
News 2023
6 Pages
-
Safe key system CKS2
10 Pages
-
Enabling Switches ZS
92 Pages
-
About EUCHNER
34 Pages
-
Transponder-coded safety switches
160 Pages
-
MGB2
80 Pages
-
Multifunctional Gate Box MGB
5 Pages
-
Multifunctional Gate Box
133 Pages
-
Product Overview Automation
8 Pages
-
Product Overview ManMachine
6 Pages
-
AC-DP-04-SA
2 Pages
-
Safety Switches with Plastic Housing
172 Pages
-
Safety switch CTP‑BI
2 Pages
-
Safety Switches with Metal Housing
220 Pages
-
EKS with USB port
2 Pages
-
Proven Systems - Proven Safe
6 Pages
-
Multiple Limit Switches
36 Pages
-
Position Switches
56 Pages
-
Safety switch CTP-Extended
2 Pages
-
Safety Switches NQ/TQ
6 Pages
-
Joystick Switches
28 Pages
-
EKS Light
8 Pages
-
Safety Relays ESM
32 Pages
-
Electronic-Key-System
24 Pages