Catalog excerpts
More than safety.
Open the catalog to page 1The Electronic-Key-System EKS This system is already established in many applications involving electronic access management on PCs and control systems. The user employs the Electronic-Key with RFID transponder to identify himself to the Electronic-Key adapter. Thanks to the special design of the Electronic-Key adapters, the Electronic-Key can be placed on the installation during operation. The EKS is widespread amongst automotive manufacturers and suppliers. Further applications include uses in the process-oriented industry, e.g. in the production of food, pharmaceutical or chemical...
Open the catalog to page 2Access the easy way... A simple connection concept as well as rapid and therefore economical integration into the control environment were at the forefront in the development of EKS Light. Compatibility with the existing EKS through the use of the same Electronic-Keys was also taken into account. Electronic access control Simple connection Simple communication, 4-bit output Very flexible use As previously with EKS, the Light version also permits controlled access to individual machines, entire installations or other facilities. The only difference is that with EKS Light, the device directly...
Open the catalog to page 3Flexibility through various operating states The application options for EKS Light are diverse, and the flexible concept with its different operating states provides flexibility for planning. What operating states are available? Depending on the applications, various operating states can be selected. Two different operating states are available in the first step. The operating state determines the function of the system, which comprises the Electronic-Key adapter and Electronic-Key. The operating state defines the scheme according to which automatic Electronic-Key recognition functions and how an...
Open the catalog to page 4Electronic-Key-Manager – EKM How are parameters assigned to Electronic-Keys? Parameter assignment for the Electronic-Keys is performed exclusively via a programming station on the PC. At least the following items are required for this purpose: A commercially available Windows PC An EKS Electronic-Key adapter with USB interface The Electronic-Key Manager EKM Light software Programming takes place via the Electronic-Key-Manager EKM software with an EKS Light input mask suitable for the operating state: The EKM Light Version is sufficient at first. It can be upgraded to an EKM single-user or full...
Open the catalog to page 5plug-in screw terminal 1,5 (rubber gasket) DIP-Schalter 50 10 1,5 (rubber gasket) DIP switch DIP-Schalter 50 10 plug-in screw terminal plug-in screw terminal Steckbare Schraubklemme Steckbare Schraubklemme Dimension drawing Interface adapter EKS Light modular Interface adapter EKS Light FSA modular Dimension drawing Electronic-Key adapter EKS Front hook modular FHM Datenblatt / Data Sheet EKS-A-SFH-G30-2000-106585 passend für Hutschiene 35mm35mm DIN EN 50022-35 / passend für Hutschiene nach nach DIN EN 50022-35 / suitable for railfor rail 35 mm according DIN EN EN 50022-35 suitable 35 35...
Open the catalog to page 6FSA Version (For Safety Applications) The Electronic-Key adapter EKS Light is alternatively available in the FSA (For Safety Applications) version. To solve the widespread problem of tampering with safety guards, EKS Light has been expanded for safety-related applications in conjunction with operating mode selection. The access rights are assigned via EKS in the first step and the desired operating mode is selected via another device in the second step. Trained personnel are thereby specifically authorized to perform critical setup and maintenance work in a special, hazardous operating mode....
Open the catalog to page 7General parameters Electronic-Key adapter compact Housing Degree of protection according to EN 60529 Ambient temperature at UB = 24 V DC Mounting cut-out according to DIN 43700 Value typ. Plastic (PA 6 GF30 grey/black) IP 65, IP 67 in mounted condition +70 33 x 68 2 plug-in screw terminals 2- and 5-pole Connection type for power supply, outputs and 2 plug-in screw terminals 4- and 5-pole (FSA version) semiconductor switching contact Conductor cross-section 0.14 ... 1.5 mm², tightening torque 0.22 Nm General parameters Electronic-Key adapter Front hook modular FHM Housing Plastic (PVDF GF30...
Open the catalog to page 8All EUCHNER GmbH + Co. KG catalogs and technical brochures
-
Electronic-Key-System EKS2
3 Pages
-
EUCHNER Safety Services
24 Pages
-
Product Guide
20 Pages
-
Electronic-Key-System EKS
60 Pages
-
Electronic-Key-System EKS
60 Pages
-
Industry 4.0
16 Pages
-
EKS with touch panel
12 Pages
-
News 2023
6 Pages
-
Safe key system CKS2
10 Pages
-
Enabling Switches ZS
92 Pages
-
About EUCHNER
34 Pages
-
Transponder-coded safety switches
160 Pages
-
MGBS
52 Pages
-
MGB2
80 Pages
-
Multifunctional Gate Box MGB
5 Pages
-
Multifunctional Gate Box
133 Pages
-
Product Overview Automation
8 Pages
-
Product Overview ManMachine
6 Pages
-
AC-DP-04-SA
2 Pages
-
Safety Switches with Plastic Housing
172 Pages
-
Safety switch CTP‑BI
2 Pages
-
Safety Switches with Metal Housing
220 Pages
-
EKS with USB port
2 Pages
-
Proven Systems - Proven Safe
6 Pages
-
Multiple Limit Switches
36 Pages
-
Position Switches
56 Pages
-
Safety switch CTP-Extended
2 Pages
-
Safety Switches NQ/TQ
6 Pages
-
Joystick Switches
28 Pages
-
Safety Relays ESM
32 Pages
-
Electronic-Key-System
24 Pages