1. Catalogs
  2. ETS Lindgren
  3. POSITIONING EQUIPMENT
video corpo

POSITIONING EQUIPMENT

POSITIONING EQUIPMENT

POSITIONING EQUIPMENT

Product catalog summary
Overview: ETS-Lindgren's Low Dielectric Tables (LDT) are designed for radiated emissions measurements, minimizing measurement influence due to their low dielectric properties. They are lightweight, portable, and constructed with materials having a dielectric constant of less than 3.0 for the support surface and less than 1.03 for the support structures.
Specifications: The tables are available in two models: LDT-1.2 and LDT-1.5. Model LDT-1.2 measures 120 cm x 100 cm, while Model LDT-1.5 measures 150 cm x 100 cm. Both models have a height of 80 cm and a load capacity of 100 kg (220 lbs). Custom sizes are available upon request.
Features: An EUT placement grid is integrated onto the table top for ease of use and accurate positioning. The tables are designed to be used with a 1.2 m diameter or larger turntable.
Performance: The tables have been tested in accordance with CISPR 16-1-4 standards in a validated 3-meter semi-anechoic chamber, ensuring minimal influence on radiated emissions measurements from 200 MHz to 18 GHz. Typical performance data is available up to 6 GHz, with additional data available upon request.
Usage: These tables are ideal for environments where accurate radiated emissions measurements are critical, especially above 1 GHz.
Contact Information: For current specifications and product enhancements, contact the ETS-Lindgren Sales Department.
See more

Catalog excerpts

POSITIONING EQUIPMENT-1

For Radiated Emissions Measurements ■ Minimal Measurement Influence ■ EUT Placement Grid (10 cm2) Distributed Load Capacity of 100 kg (220 lb) Durable Construction ETS-Lindgren’s Low Dielectric Tables (LDT) are lightweight, portable test tables, constructed with materials selected for their low dielectric properties. The construction materials for the EUT's support surface have a dielectric constant of <3.0, with each table's support structures having a dielectric constant of <1.03. The result is a table having virtually no influence on radiated emissions measurements, especially above 1 GHz, where frequencies are affected most. For ease of use and accurate EUT positioning, an EUT placement grid is integrated onto the test table top. Standard Configuration ■ EUT Test Table Assembly The results were measured in accordance with CISPR 16-1-4 (Section 5.5; how to evaluate the test table's effect on radiated emissions measurements from 200 MHz to 18 GHz). The tests were performed in a validated 3-meter semi-anechoic chamber. LDT Tables are available in two sizes; 1.2 m x 1.0 (Model LDT-1.2) and 1.5 m x 1.0 m (Model LDT-1.5). Both test tables have a load capacity of 100 kg (220 lbs). Custom sizes are available; please contact ETS-Lindgren for details. Both LDT models are designed to be used with a 1.2 m diameter or larger turntable. Technical Specifications WETS-UNDGRENAn ESCO Technologies Company ets-lindgren.com

 Open the catalog to page 1
POSITIONING EQUIPMENT-2

Typical Performance up to 6 GHz 6 GHz to 18 GHz Data Available Upon Request An ESCO Technologies Company ets-lindgren.com Information presented is subject to change as product enhancements are made. Contact ETS-Lindgren Sales Department for current specifications.

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.