video corpo

Modular contactors for installation into home distribution boards
24Pages

{{requestButtons}}

Catalog excerpts

Modular contactors for installation into home distribution boards - 1

Modular contactors for installation into distribution boards ETICON Modular contactors for installation into distribution boards Modular contactor for installation into distribution board Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centers, sport centers, production halls, warehouses etc. They are used for remote switching and automatic control of electric devices and equipment, such as: n lightning n all types of pumps n air-conditioning n electric heating n single-phase and three-phase motors They excel in silent operation, long mechanical life time and high quality. The contactors are designed for mounting on 35 mm mounting rail in accordance with the EN 60715 standard and they can be leaded by means of lead covers. The auxiliary contact block is available for signalization and ventilation module is available for preventing exceeded heating when contactors are used side-by-side. All contactors have degree of protection IP20. Besides the basic AC controlled types R20, R25, R40 and R63, types with increased silent operation RD20, RD25, RD40 and RD63 are available. Due to DC magnet and rectifier enable DC and AC voltage control. Surge arrestor is built in for over voltage protection. Types R20-R, RD20-R, R25-R and RD25-R are upgraded versions of basic types of modular contactors. Besides basic functions they enable manual control with a handle. Description of the handle positions: n A: the contactor functions as an installation contactor without manual control n O: permanently OFF n I: manual shifting the handle from position A to I causes the contactor to close; when control voltage is applied, the handle is automatically set to position A. Types RD20-R and RD25-R are provided with a varistor for over voltage protection and a rectifier, which enables control with AC and DC voltage. Contactors with manual control enable: n switching depending on tariff (selection of the most convenient tariff) n switching when control voltage is not applied Technical specifications according to: EN60947-4-1; EN60947-5-1; VDE 0660, IEC 947-4-1; IEC 947-5-1 60

Open the catalog to page 1
Modular contactors for installation into home distribution boards - 2

Modular contactors for installation into distribution boards - type R technical data on page 299

Open the catalog to page 2
Modular contactors for installation into home distribution boards - 3

Modular contactors for installation into distribution boards - type R Distance piece technical data on page 299

Open the catalog to page 3
Modular contactors for installation into home distribution boards - 5

Modular contactors for installation into distribution boards - type RD, R...R, RD...R 1 -pole, ON - OFF - AUTO, 1 module (17,5 mm), 20 A (AC1,400 V) Wiring diagram technical data on page 304

Open the catalog to page 5
Modular contactors for installation into home distribution boards - 6

Modular contactors for installation into distribution boards - type RD, R...R, RD...R Auxiliary contactor block for contactors R25, R40, R63 (max. 1 piece) Code No. RN-20 002464068 RN-02 002464069 RN-11 Wiring diagram 002464070 13 23 14 24 13 21 14 22 11 21 12 22 Weight [g] Packaging [pcs] 30 1 30 1 30 1 ETICON Type * The auxiliary switch should not be applied in combination with RD20, R20-R and RD20-R Sealing cover Type Code No. Weight [g] Packaging [pcs] SC20 002464071 3 2 SC25 002464072 4 2 SC40/63 002464073 5 2 Type Code No. Weight [g] Packaging [pcsg IKV 002464074 6 1 Distance piece...

Open the catalog to page 6
Modular contactors for installation into home distribution boards - 7

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:12.00pt "Georgia", serif; } .font1 { font:8.00pt "Times New Roman", serif; } .font2 { font:10.00pt "Times New Roman", serif; } .font3 { font:4.00pt "Trebuchet MS", sans-serif; } .font4 { font:6.00pt "Trebuchet MS", sans-serif; } .font5 { font:7.00pt "Trebuchet MS", sans-serif; } .font6 { font:10.00pt "Trebuchet MS", sans-serif; } .font7 { font:19.00pt "Trebuchet MS", sans-serif; } .font8 { font:22.00pt "Trebuchet MS", sans-serif; } _en Modular contactors for installation into distribution boards - type RD, R...R,...

Open the catalog to page 7
Modular contactors for installation into home distribution boards - 8

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:12.00pt "Georgia", serif; } .font1 { font:8.00pt "Times New Roman", serif; } .font2 { font:10.00pt "Times New Roman", serif; } .font3 { font:13.00pt "Times New Roman", serif; } .font4 { font:17.00pt "Times New Roman", serif; } .font5 { font:4.00pt "Trebuchet MS", sans-serif; } .font6 { font:6.00pt "Trebuchet MS", sans-serif; } .font7 { font:10.00pt "Trebuchet MS", sans-serif; } .font8 { font:20.00pt "Trebuchet MS", sans-serif; } TI Miniature and motor contactors, capacitor duty contactors, auxiliary contactors...

Open the catalog to page 8
Modular contactors for installation into home distribution boards - 14

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:12.00pt "Georgia", serif; } .font1 { font:8.00pt "Times New Roman", serif; } .font2 { font:10.00pt "Times New Roman", serif; } .font3 { font:13.00pt "Times New Roman", serif; } .font4 { font:4.00pt "Trebuchet MS", sans-serif; } .font5 { font:6.00pt "Trebuchet MS", sans-serif; } .font6 { font:9.00pt "Trebuchet MS", sans-serif; } .font7 { font:16.00pt "Trebuchet MS", sans-serif; } .font8 { font:20.00pt "Trebuchet MS", sans-serif; } .font9 { font:22.00pt "Trebuchet MS", sans-serif; } en Miniature and motor...

Open the catalog to page 14
Modular contactors for installation into home distribution boards - 15

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:12.00pt "Georgia", serif; } .font1 { font:5.00pt "Sylfaen", serif; } .font2 { font:8.00pt "Times New Roman", serif; } .font3 { font:10.00pt "Times New Roman", serif; } .font4 { font:17.00pt "Times New Roman", serif; } .font5 { font:4.00pt "Trebuchet MS", sans-serif; } .font6 { font:5.00pt "Trebuchet MS", sans-serif; } .font7 { font:6.00pt "Trebuchet MS", sans-serif; } .font8 { font:7.00pt "Trebuchet MS", sans-serif; } .font9 { font:10.00pt "Trebuchet MS", sans-serif; } .font10 { font:20.00pt "Trebuchet MS",...

Open the catalog to page 15
Modular contactors for installation into home distribution boards - 16

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:12.00pt "Georgia", serif; } .font1 { font:8.00pt "Times New Roman", serif; } .font2 { font:10.00pt "Times New Roman", serif; } .font3 { font:32.00pt "Times New Roman", serif; } .font4 { font:4.00pt "Trebuchet MS", sans-serif; } .font5 { font:6.00pt "Trebuchet MS", sans-serif; } .font6 { font:10.00pt "Trebuchet MS", sans-serif; } .font7 { font:20.00pt "Trebuchet MS", sans-serif; } TI Miniature and motor contactors, capacitor duty contactors, auxiliary contactors and overload relays z o y code No. wiring diagram...

Open the catalog to page 16

All ETI catalogs and technical brochures

  1. EFI eV

    8 Pages

  2. RCCB-Btype

    3 Pages

  3. GREEN PROTECT

    84 Pages

  4. Battery Fuse

    36 Pages

  5. ETICONNECT

    28 Pages

  6. EVE program

    92 Pages

  7. RCBO KZS-1M

    2 Pages

Archived catalogs