Specifications:
  • Rated Voltage (Un): 230 V a.c.
  • Rated Current (In): 6 - 40 A
  • Rated Frequency (fn): 50 Hz
  • Rated Short-Circuit Capacity: 10 kA
  • Tripping Characteristic: B or C
  • Rated Residual Current: 30 mA
  • Type: AC
  • Terminals Line/Load: 1-25 mm2 / 1-16 mm2
  • Build-in Width: 18 mm
  • Standard: IEC 61009-1 / 61009-2
  • Length of Neutral Conductor: 600 mm
  • Operating Temperature: -25°C to +40°C
  • I∆m: 4500 A
Product Description:

The KZS 1M-FN is a residual current circuit breaker with integral overcurrent protection (RCBO), designed to be functionally dependent on line voltage. It is a single pole device that switches the phase pole while keeping the neutral pole fixed. The device operates at voltages above 85V and includes a sealing option.

Dimensions:

The product dimensions are provided in a schematic, indicating a compact design suitable for various installations.

Connection Details:
  • The blue conductor, with a length of 600 mm, serves as the neutral conductor on the line side.
  • The white conductor is connected to FE and is used for earthing the electronics.
Packaging and Codes:

The product is available in various rated currents (6A to 40A), each with specific code numbers for tripping characteristics B and C. The weight ranges from 177g to 192g, and packaging is typically 1 piece per box, with 42 boxes per package.

See more

Catalog excerpts

KZS 1M FN Residual current circuit breaker with integral overcurrent protection NEW-1

Residual current circuit breaker with integral overcurrent protection Investing in your future OPERATION PART FINANCED EfTHE EUROPEAN UNION European Regional Development Fund KZS 1M-FN is a residual current circuit breaker with integral overcurrent protection (RCBO), functionally dependent on line voltage. It comes in a single pole version that switches the phase pole while the neutral pole stays fixed. KZS 1M-FN is dependent on voltage and operates at voltages above 85V. KZS 1M-FN also has a sealing possibility. Technical data Rated short-circuit capacity Tripping characteristic Rated residual current Terminals line/load Build-in width Length of neutral conductor Operating temperature

 Open the catalog to page 1
KZS 1M FN Residual current circuit breaker with integral overcurrent protection NEW-2

Blue conductor with length of 600 mm is the neutral conductor on the line side. White conductor is connected to FE and is used for earthing the electronics.

 Open the catalog to page 2

All ETI catalogs and technical brochures

  1. EFI eV

    8  Pages

  2. RCCB-Btype

    3  Pages

  3. GREEN PROTECT

    84  Pages

  4. Battery Fuse

    36  Pages

  5. ETICONNECT

    28  Pages

  6. EVE program

    92  Pages

  7. RCBO KZS-1M

    2  Pages

  8. RCBO KZS 2M2p

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.