Overview
This document provides comprehensive technical specifications and operational details for low breaking capacity molded case circuit breakers (MCCBs) and switch disconnectors, specifically focusing on the EB2S, EB2, and ED2 series. It includes descriptions of features, advantages, and available accessories, ensuring safety and reliability in electrical applications.
Specifications
The EB2S series offers MCCBs with frame sizes of 160A and 250A, available in fixed and adjustable protection options. The EB2 series covers a range from 20A to 1600A, featuring high short-circuit breaking capacity and adjustable thermal and magnetic trip settings. The ETIBREAK 2 series includes models with current ratings from 125A to 1600A, operational voltage up to 690V AC and 600V DC, and insulation voltage of 800V.
Advantages
The EB2S series is noted for its compact design, compliance with IEC 60204-1 safety standards, and ease of accessory installation. The EB2 series offers high dielectric withstand voltages, fast break mechanisms, and reduced energy let-through, minimizing thermal and electrodynamic stresses.
Accessories
Internal accessories for the EB2S 160 and 250 include auxiliary switches, alarm switches, shunt trip units, and undervoltage trip units. External accessories include breaker and panel mounted handles, busbars, terminal covers, and rear connections. Motor operators and cable clamps are detailed for the EB2S 250.
Technical Data
Technical data includes current ratings, breaking capacities, adjustment settings, weight, and packaging details. The document highlights economic (L), standard (S), and high (H) short-circuit breaking capacities across different models.
Installation and Dimensions
Options for front connection, rear connection, plug-in, draw-out, and DIN rail mounting are available. Dimensions and weight vary by model, with 3-pole and 4-pole configurations.
Operation and Endurance
Features include direct opening action, toggle operation, and motor operator options. Endurance is specified in terms of electrical and mechanical cycles, with compliance to IEC 60947-2 and EN 60947-2 standards.
Thermal Magnetic Adjustments
Thermal adjustment ranges from 63% to 100% of nominal current, with magnetic adjustment available to match short-circuit protection to load characteristics.
Time-Current Characteristics
Curves are provided for various models, showing tripping times and current ratings under different conditions, including ambient compensating curves for temperature variations.
Electronic Protection Units
Available for models from 250A to 1600A, offering overload, delayed short-circuit, and instantaneous protection, with adjustments via dials for rated current and characteristic selection.
Residual Current Protection
Adjustable tripping thresholds for earth leakage protection range from 30mA to 3A, with time delay settings for residual current protection.
Internal Accessories
Includes status indication switches, shunt trips, undervoltage trips, and auxiliary switches, with specific configurations and limitations noted for accessory installation.
Auxiliary and Alarm Switches
Status indication switches are mounted on the left side of the MCCB, with specifications for voltage and current ratings for both AC and DC loads.
Shunt Trip Unit
Rated voltage ranges for AC and DC, with permissible voltage range and breaker contact operation details.
Undervoltage Trips
Similar voltage ratings as shunt trips, with power supply capacity and excitation current specifications.
Motorized Operation
Features high-speed actuation, silent operation, and "lock-in off" capability, with auto reset feature.
Operation Precautions
Ensure operation voltage is within specified range, use specified operation switches and noise filters, and employ electrical interlocks to avoid simultaneous closing.
Additional Information
Contact details for Terasaki Electric's global offices are provided, with a note that specifications are subject to change without notice.
See more

Catalog excerpts

ETIBREAK Moulded case circuit breakers and switch disconnectors-1

ETIBREAK Low breaking capacity moulded case circuit breakers EB2S EB2 and low voltage switch disconnectors ED2 ETIBREAK ETIBREAK Low voltage moulded case circuit breakers 312 Low voltage moulded case circuit breakers with residual current protection EB2R Technical data Moulded case circuit breakers and switch disconnectors POWER NEEDS CONTROL

 Open the catalog to page 1
ETIBREAK Moulded case circuit breakers and switch disconnectors-2

etibreak £Tt Low breaking capacity moulded case circuit breakers Low breaking capacity moulded case circuit breakers Advantages of low breaking capacity MCCBs New series EB2S of MCCBs has excellent performances with reduced dimensions and new modern design. Unique accessory cover opens with only one screw. Practical internal accessories can be installed with one touch: - auxiliary switch - alarm switch - shunt trip unit - undervoltage trip unit Customer can select between fixed and adjustable protection: EB2S series complies to safety recommendation standard IEC 60204-1. EB2S is marked with IEC...

 Open the catalog to page 2
ETIBREAK Moulded case circuit breakers and switch disconnectors-3

4 1,00 Technical data on page 363 307

 Open the catalog to page 3
ETIBREAK Moulded case circuit breakers and switch disconnectors-4

Low breaking capacity moulded case circuit breakers 1,0 308 Technical data on page 363

 Open the catalog to page 4
ETIBREAK Moulded case circuit breakers and switch disconnectors-5

etibreak EB2S 250 adjustable protection Technical data on page 363 309

 Open the catalog to page 5
ETIBREAK Moulded case circuit breakers and switch disconnectors-6

Low breaking capacity moulded case circuit breakers Auxiliary switch, PS2S 160-250 Alarm switch, SS2S 160-250 Shunt trip unit, DA2S 160-250 AC 200-240V Shunt trip unit, DA2S 160-250 AC 380-450V Shunt trip unit, DA2S 160-250 DC 24V Undervoltage trip unit, NA2S 160-250 AC 200-240V Undervoltage trip unit, NA2S 160-250 AC 380-450V Undervoltage trip unit, NA2S 160-250 DC 24V External accessories Accessories for EB2S 160 Breaker mounted handle, RO2S 160 Panel mounted handle, RO2S 160P Attach busbar, ZB2S 160/3 Spread Attach busbar, ZB2S 160/4 Spread Interpole barrier, IZ2S 160 Terminal covers, PR2S...

 Open the catalog to page 6
ETIBREAK Moulded case circuit breakers and switch disconnectors-7

etibreak Technical data on page 369 311

 Open the catalog to page 7
ETIBREAK Moulded case circuit breakers and switch disconnectors-8

Low voltage moulded case circuit breakers and low voltage switch disconnectors Low voltage moulded case circuit breakers are used for the switching and protection of power supply cables, motors and other electrical equipment against overloads and short circuit faults. They provide, beside protection function, other functions as remote ON/OFF operation, undervoltage protection, main switch etc. They are available in range from 20 A up to1600 A in 3 and 4 pole versions. Advantages: ■ Small dimensions,modular sizes ■ Possibility of field-instalable accessories - up to 1600A frame size series 2 (EB2) ■...

 Open the catalog to page 8
ETIBREAK Moulded case circuit breakers and switch disconnectors-9

Technical data on page 331 313

 Open the catalog to page 9
ETIBREAK Moulded case circuit breakers and switch disconnectors-10

Low voltage moulded case circuit breakers and low voltage switch disconnectors ETIBREAK EB2 160/250 314 Technical data on page 331 - 334

 Open the catalog to page 10
ETIBREAK Moulded case circuit breakers and switch disconnectors-11

Technical data on page 334 315

 Open the catalog to page 11
ETIBREAK Moulded case circuit breakers and switch disconnectors-12

Low voltage moulded case circuit breakers and low voltage switch disconnectors Microprocessor's MCCBs Microprocessor's MCCBs are available in frame sizes from 250 A up to 1600 A, with rated current from 40 A up to 1600 A. All frame sizes have adjustable thermal and magnetic protection. Series 2: Protection against overload can be adjusted between 0,4 - 1 x In, meanwhile short-circuit protection has already preset different curves, which can be easily selected according to the type of load. Optional Functions: N - Neutral Protection A - Standard relay with LSI Characteristic (where no letters...

 Open the catalog to page 12
ETIBREAK Moulded case circuit breakers and switch disconnectors-13

Technical data on page 332-334 317

 Open the catalog to page 13
ETIBREAK Moulded case circuit breakers and switch disconnectors-14

Low voltage moulded case circuit breakers and low voltage switch disconnectors Low voltage switch disconnector ETIBREAK ED2 ETIBREAK ED2 125-1600 Note: All internal and external accessories for MCCBs can also be mounted to corresponding type of switch disconnectors. 318 Technical data on page 334, 337

 Open the catalog to page 14
ETIBREAK Moulded case circuit breakers and switch disconnectors-15

Low voltage moulded case circuit breakers with residual current protection Low voltage moulded case circuit breakers with residual current protection Main features and advantages Adjustable residual current tripping thresholds between 30mA and 3A. Adjustable time delay for residual current protection between 60ms and 700ms including INST (instantaneous) and NT (No Trip). Type A: Tripping is ensured for residual sinusoidal AC in the presence of residual pulsating DC. Voltage Presence LED Indicator and Trip Indicator (the yellow button pops up to indicate tripping due to residual current) Adjustable...

 Open the catalog to page 15
ETIBREAK Moulded case circuit breakers and switch disconnectors-16

Low voltage moulded case circuit breakers with residual current protection Main advantages: ■ Combined protection against overloads, short circuits and earth leakage integrated in one device ■ The new EB2R save the space ■ The EB2R has the same dimensions and fixing as the EB2 MCCBs ■ The EB2R eliminates the need for either an external relay with current transformers or add-on block ■ Residual current is adjustable ■ Earth leakage protection time delay is adjustable ■ Wide range of accessories (as MCCB - only shunt/undervoltage trip units can not be fitted to EB2R) Note: all internal and external...

 Open the catalog to page 16
ETIBREAK Moulded case circuit breakers and switch disconnectors-17

Note: all internal and external accessories can be used with EB2R - only exceptions are DA shunt trip unit and NA undervoltage trip unit (cannot be fitted to EB2R) etibreak Residual current monitor and pre trip module Residual current monitor and pre trip module (optional) ■ normally open alarm contact (2A, 250V AC) closes on detection of residual current. Alarm treshold is adjustable. ■ Green LED indicates voltage is present ■ Red LED provides visual indications of residual current. ■ Can be configured to provide trip + alarm or alarm only. ■ Remote trip terminals allow tripping by push-button ■...

 Open the catalog to page 17
ETIBREAK Moulded case circuit breakers and switch disconnectors-18

AccessoriesInternal accessoriesetibreak Undervoltage trip for EB2, ED2 125-630 important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Undervoltage trip for EB2, ED2 125-630AF - Time Delay Important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Time delay of500ms Time delay units are fitted to the outside of MCCBs Undervoltage trip for EB2, ED2 400-630AF only 4p Important note: The shunt...

 Open the catalog to page 18
ETIBREAK Moulded case circuit breakers and switch disconnectors-19

important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Time delay of 500ms Time delay units are fitted to the outside of MCCBs Undervoltage trip for EB2, ED2 1250-1600AF - Time Delay Important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Time delay of 500ms Time delay units are fitted to the outside of MCCBs etibreak Auxiliary & Alarm switch for EB2, ED2 125-1600 Important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Important note: The shunt...

 Open the catalog to page 19

All ETI catalogs and technical brochures

  1. EFI eV

    8  Pages

  2. RCCB-Btype

    3  Pages

  3. GREEN PROTECT

    84  Pages

  4. Battery Fuse

    36  Pages

  5. ETICONNECT

    28  Pages

  6. EVE program

    92  Pages

  7. RCBO KZS-1M

    2  Pages

  8. RCBO KZS 2M2p

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.