Product catalog summary
Overview: This document provides technical specifications and installation guidelines for EFI eV Residual Current Circuit Breakers (RCCBs) designed for electric vehicle (EV) charging stations. It emphasizes safety and reliability in e-mobility applications.
Key Features:
  • Basic installation requirements are engraved on the housing for easy reference.
  • Enhanced protection against accidental contact with live parts.
  • Technical and installation information is accessible on the device's exterior.
  • QR codes provide access to test measurements, manuals, and technical materials.
  • Supports both top and bottom terminal supply, compatible with single and three-phase busbars.
  • Rated conditional short-circuit current is 10 kA.
  • Complies with IEC 60364-7-722 standards for low-voltage electrical installations for EVs.
  • Real contact position indication for easy status identification.
Technical Specifications:
  • Rated Voltage: 400/415V AC
  • Rated Current: 25, 40, 63 A
  • Rated Frequency: 50/60Hz
  • DC Tripping Threshold: 6 mA
  • Rated Insulation Voltage: 440V
  • Impulse Withstand Voltage: 4kV
  • Mechanical Endurance: 10,000 cycles
  • Electrical Endurance: 2,000 cycles
  • Operating Temperature: -25°C to +65°C
  • Storage Temperature: -40°C to +85°C
Installation Guidelines:
  • For plug-in units, additional protection against DC residual currents above 6 mA is required.
  • For fixed connections, EFI eV provides complete protection.
  • In TT systems, stricter switch-off times necessitate additional protection with EFI eV.
  • For multiple charging units, a Type B RCCB is required to handle cumulative DC residual currents.
Design Recommendations:
  • Ensure proper pressure on cables when using more than two cables.
  • Combination of rigid single-wire and flexible multi-wire conductors is not allowed.
See more

Catalog excerpts

EFI eV-1

EFI eV Residual Current Circuit Breakers for Protection of EV Charging Stations With automated 100% control of all key parameters of each product Reliable protection for e-mobility For wall- and pedestalmounted charging stations

 Open the catalog to page 1
EFI eV-2

Advantages of EFI eV aa Meets requirements from standard IEC 60364-7-722 --> Low-Voltage electrical Installations - Requirements for special installations or locations - Supplies for electric vehicles aa Individual test measurements and other production data for each device can be read from the QR code, as well as instruction manuals and other technical materials installation information can be found on the front and side of the device aa detects smooth DC residual currents above 6 mA aa Basic installation requirements are engraved into housing of terminals against touching the parts under voltage...

 Open the catalog to page 2
EFI eV-3

Technical features Technical data EFI-4 A eV Type Electrical Rated Voltage Un Rated current In Rated frequency fn Mode of operation Sensitivity Rated insulation voltage Ui Rated impulse withstand voltage (1,2/50μs) Electrical isolation Rated residual operating current I∆n DC tripping treshold Rated conditional short-circuit current Icn Rated making and breaking capacity Im Max back-up fuse for short circuit protection Voltage range test circuit Min. operating voltage Standards Mechanical Endurance Electrical endurance Shock resistance Resistance to vibrations acc. To IEC 60068-2-7 400/415V AC...

 Open the catalog to page 3
EFI eV-4

Maximum power dissipation EFI-4 A eV P/pole [W] 1,33 3,12 6,62 conductor cross- Number of single conductors, rigid, section single-wire Cu conductor [mm2] 1 2 3 4 5 1,5      2,5      4      6      10      16      25      Remark: When you use more than 2 cables you have to be careful how those cables are inserted, due to insure proper presure on each cable conductor cross- Number of single conductors, flexible Cu section conductors [mm2] 1 2 3 4 5 6 1,5       2,5       4       6       10       16

 Open the catalog to page 4
EFI eV-5

Design recommendations aa the charging unit is pluged into an If existing socket, protected with a Type A RCCB, additional protection against smooth DC residual currents above 6 mA must be provided (IEC 60364-7-722). EFI-P Type A I∆n= 30 mA

 Open the catalog to page 5
EFI eV-6

aa the charging unit has a fixed If connection, EFI eV will provide complete protection against residual currents.

 Open the catalog to page 6
EFI eV-7

aa these systems, switch-off times must In comply to stricter rules so even the charging units with fixed connection require a Type A RCCB, which needs to be additionally protected against smooth DC residual currents above 6 mA by EFI eV. EFI-P Type A I∆n= 30 mA

 Open the catalog to page 7
EFI eV-8

aa more charging units are in use, the first If RCCB must be a Type B device to protect from the sum of all smooth DC residual currents. Each charging plug socket must also be protected with EFI eV. EFI-4 B-S Type B Selective I∆n= 300 mA November 2019 ETI d.o.o. withholds the right to make changes and additions to any information contained herein.

 Open the catalog to page 8

All ETI catalogs and technical brochures

  1. RCCB-Btype

    3  Pages

  2. GREEN PROTECT

    84  Pages

  3. Battery Fuse

    36  Pages

  4. ETICONNECT

    28  Pages

  5. EVE program

    92  Pages

  6. RCBO KZS-1M

    2  Pages

  7. RCBO KZS 2M2p

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.