EFI eV Residual Current Circuit Breakers for Protection of EV Charging Stations With automated 100% control of all key parameters of each product Reliable protection for e-mobility For wall- and pedestalmounted charging stations
Open the catalog to page 1Advantages of EFI eV aa Meets requirements from standard IEC 60364-7-722 --> Low-Voltage electrical Installations - Requirements for special installations or locations - Supplies for electric vehicles aa Individual test measurements and other production data for each device can be read from the QR code, as well as instruction manuals and other technical materials installation information can be found on the front and side of the device aa detects smooth DC residual currents above 6 mA aa Basic installation requirements are engraved into housing of terminals against touching the parts under...
Open the catalog to page 2Technical features Technical data EFI-4 A eV Type Electrical Rated Voltage Un Rated current In Rated frequency fn Mode of operation Sensitivity Rated insulation voltage Ui Rated impulse withstand voltage (1,2/50μs) Electrical isolation Rated residual operating current I∆n DC tripping treshold Rated conditional short-circuit current Icn Rated making and breaking capacity Im Max back-up fuse for short circuit protection Voltage range test circuit Min. operating voltage Standards Mechanical Endurance Electrical endurance Shock resistance Resistance to vibrations acc. To IEC 60068-2-7 400/415V...
Open the catalog to page 3Maximum power dissipation EFI-4 A eV P/pole [W] 1,33 3,12 6,62 conductor cross- Number of single conductors, rigid, section single-wire Cu conductor [mm2] 1 2 3 4 5 1,5 2,5 4 6 10 16 25 Remark: When you use more than 2 cables you have to be careful how those cables are inserted, due to insure proper presure on each cable conductor cross- Number of single conductors, flexible Cu section conductors [mm2] 1 2 3 4 5 6 1,5 2,5 4 6 10 16
Open the catalog to page 4Design recommendations aa the charging unit is pluged into an If existing socket, protected with a Type A RCCB, additional protection against smooth DC residual currents above 6 mA must be provided (IEC 60364-7-722). EFI-P Type A I∆n= 30 mA
Open the catalog to page 5aa the charging unit has a fixed If connection, EFI eV will provide complete protection against residual currents.
Open the catalog to page 6aa these systems, switch-off times must In comply to stricter rules so even the charging units with fixed connection require a Type A RCCB, which needs to be additionally protected against smooth DC residual currents above 6 mA by EFI eV. EFI-P Type A I∆n= 30 mA
Open the catalog to page 7aa more charging units are in use, the first If RCCB must be a Type B device to protect from the sum of all smooth DC residual currents. Each charging plug socket must also be protected with EFI eV. EFI-4 B-S Type B Selective I∆n= 300 mA November 2019 ETI d.o.o. withholds the right to make changes and additions to any information contained herein.
Open the catalog to page 8All ETI catalogs and technical brochures
-
VV/HH - High voltage fuse-links
10 Pages
-
RCCB-Btype
3 Pages
-
GREEN PROTECT
84 Pages
-
Special Purpose Fuses
82 Pages
-
Battery Fuse
36 Pages
-
Three-phase capacitors
8 Pages
-
ETICONNECT
28 Pages
-
PFC power factor controllers
4 Pages
-
ETITEC : SURGE ARRESTERS
26 Pages
-
ETITRAFO program
10 Pages
-
Air circuit breakers
4 Pages
-
Rotary cam switches
10 Pages
-
ETIMETER program
6 Pages
-
ETICONTROL program
4 Pages
-
EVE program
92 Pages
-
RCBO KZS-1M
2 Pages
-
RCBO KZS 2M2p
8 Pages
-
Miniature circuit breakers
16 Pages
-
NH DC 1000V aR
1 Pages
-
C : Cylindrical fuse-links
2 Pages
-
Low voltage fuse-links D0
1 Pages
-
Low voltage fuse-links D
2 Pages
-
Actuators and Indicators
10 Pages
-
Change-over switches LAS
1 Pages
-
Switch disconnectors LA
2 Pages
-
Switch disconnectors LAS
3 Pages
-
VV : HIGH VOLTAGE FUSE-LINKS
10 Pages
Archived catalogs
-
TECHNICAL CERAMICS
48 Pages
-
TOOLS AND EQUIPMENT
8 Pages