The SigmaCheck 2 Eddy Current Conductivity Meter is designed for accurate conductivity measurements, offering reliability, usability, and cost-effectiveness. It is suitable for various industries including aerospace, metals processing, and quality assurance.

Applications
The device is used for material verification, heat treatment verification, damage investigation, material ageing assessment, and more. It can measure non-conductive coating thickness and determine material purity.

Compliance
The SigmaCheck 2 complies with several inspection procedures such as Boeing BAC5651, Airbus AITM 6-6004, ASTM E1004, and others.

Specifications
- Dimensions: 168mm x 85mm x 30mm with rubber boot.
- USB connection for PC link and charging.
- High-resolution color display.
- Conductivity range: 0.5% IACS to 110% IACS.
- Operating frequencies: 60kHz to 480kHz, with an option for 960kHz.
- Lightweight and ergonomic design.

Advantages
- User-programmable display and data storage.
- Multiple language support.
- Real-time PC control via USB.
- Firmware upgradable in the field.

Key Features
- High-resolution display with customizable settings.
- Rapid display of conductivity results.
- Excellent data reporting and battery life.
- Field exchangeable probes.

Understanding Conductivity
Conductivity measures a material's ability to conduct electric current, inversely related to resistivity. The SigmaCheck 2 uses a three-point reference method for accurate readings.

Technical Specifications
- Conductivity range: 0.5% IACS to 110% IACS.
- Accuracy: Requires thermal equilibrium and stabilization.
- Display resolution: Up to 3 decimal places.
- Temperature measurement: In-probe sensor, range 0°C to +50°C.
- Environmental range: 0 to 95% relative humidity, 0°C to +50°C.
- Power: 2 x 1.5 V AA NiMH Batteries, up to 9 hours life.

Accessories
Includes calibration blocks, probes, and optional extras like a rugged transit case and small probe.

Company Information
ETher NDE provides innovative eddy current testing solutions, with a focus on client needs and product quality. Founded by John Hansen and Mike Reilly, the company has extensive experience in non-destructive testing.
See more

Catalog excerpts

SigmaCheck2 Conductivity Meter-1

FULLY FEATURED EDDY CURRENT CONDUCTIVITY METER

 Open the catalog to page 1
SigmaCheck2 Conductivity Meter-2

Material verification / sorting. Heat treatment verification. Heat or fire damage investigation. Lightning damage investigation. Material ageing assessment. Measuring phosphor content of Cu alloys. Monitoring of deposition process for non-ferrous material on a non-ferrous substrate. Monitoring the condition of highly stressed parts Forged/plated material verification. Non-conductive coating thickness measurement. Determining the purity / composition of materials i.e. gold bullion and coins. Aircraft structures e.g. Paint thickness measurement. Assessment of ageing of alloys. COMPLIANCE TO PROCEDURES...

 Open the catalog to page 2
SigmaCheck2 Conductivity Meter-3

Calibration Blocks. Width: 85mm (3.3") with rubber boot on. 80mm (3.1") without rubber boot. USB Connection for easy PC , link. Also acts as Charger connection. Thermal Bridge for Stability. Temperature Readout. Programmable High Resolution Colour Display. Alarm Indicators. Length: 168mm (6.6") with rubber boot on (163mm (6.4") without rubber boot). With Calibration Blocks and rubber boot the length is 179mm (7.0"). Simple, Easy-To-Navigate keypad. Depth: 30mm (1.1") with rubber boot on (25mm (1.0") without rubber boot).

 Open the catalog to page 3
SigmaCheck2 Conductivity Meter-4

Advantages High resolution colour display (2.8"/71mm, 320 pixels by 240 pixels). Lockdown mode allows advanced users to lock down features and settings for basic operator mode. Accurate conductivity range (0.5% IACS to 110% IACS, 0.28-64 Ms/m). Wide range of frequencies for testing thin materials (60kHz, 120kHz, 240kHz, 480kHz). Option of 960kHz. Non-conductive coating thickness. Measurement display up to 0.5mm. Lightweight (350 grams / 12 oz). Ergonomic slim-line case design and easy to hold probe with adjustable finger-grip. Two-year warranty on instrument (excludes batteries). KEY BENEFITS...

 Open the catalog to page 4
SigmaCheck2 Conductivity Meter-5

Sigma Check Conductivityl 3820 %IACS Off OO 1S.2°C . HIGH RESOLUTION DISPLAY The full colour 2.8" LCD display screen is 320 x 240 pixels providing excellent resolution and displaying conductivity and lift-off results with up to three decimal places precision. The display features an adjustable LED backlight allowing the Operator to set their required screen brightness. The Operator can also customise both the background colours and text colours to meet their personal preference. RAPID DISPLAY OF CONDUCTIVITY RESULTS The SigmaCheck 2 offers a choice of four frequencies (60, 120, 240 and 480kHz)...

 Open the catalog to page 5
SigmaCheck2 Conductivity Meter-6

Understanding Conductivity Ohms Law Equation: I = Current (Amps) Conductivity is widely used to indicate material type and determine the state of heat treatment. V = Voltage (Volts) R = Resistivity (ohms) Electrical Conductivity Equation: O~= R = O"A l = length (cm) A = Area (cm2) R = Electrical Resistance of a uniform specimen of the material (ohms) O“ = Conductivity (ohm-1 cm-1) In order to give accurate readings the SigmaCheck 2 uses a three-point reference method. The first measurement with the probe in the air and then two further measurements are required which span the range of interest....

 Open the catalog to page 6
SigmaCheck2 Conductivity Meter-7

Specification Detachable, Durable Rubber Boot with Useful Belt Strap Mains Charger Calibration Blocks Detachable Back Stand Ergonomically Designed Probe Optional Extras Available Inspection Technology Operating Frequencies Conductivity Range Accuracy Display Resolution Lift Off Temperature Measurement Automatic Temperature Compensation Environmental Range Display Construction & Storage Conductivity Standards Power Size (length x width x depth) Weight Data Logger Memory PC Connectivity Probes Accessories Eddy Current 60 kHz, 120 kHz, 240 kHz, 480 kHz. Option of 960 kHz 0.5 % IACS to 110 % IACS,...

 Open the catalog to page 7
SigmaCheck2 Conductivity Meter-8

ETher NDE continually strives to provide innovative solutions to eddy current testing in all possible inspection conditions. Offering a range of innovative eddy current testing instruments and probes, ETher NDE will endeavour to find the solution that best fits our client's specific needs. At ETher NDE we pride ourselves on our ability to remain client focussed, conducting our business with three simple promises to you: 1. The ability to speak to someone who understands our products and your application. 2. Industry leading delivery on goods and the ability to respond to your challenges. 3. Our...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.