eTWIN PDE

eTWIN PDE

eTWIN PDE

Product catalog summary
Overview
The eTwin PDE is a dosing and regulation system designed for measuring and controlling two parameters, specifically for the pool industry. It includes two dosing pumps and controllers for pH, Redox, Chlorine, and temperature measurements. The system is available in both peristaltic and solenoid versions.
Key Features
  • Backlighted graphic display with a 5-key keypad.
  • Manual dosing capability with 0 to 120 pulses per minute.
  • Proportional dosing through self-regulation of stroke frequency.
  • Flow rate up to 5 l/h and pressure up to 6 bar.
  • Measurement ranges: pH (0-14), Redox (-1000 to +1400 mV), PPM (0-200 ppm), Temperature (0-100°C).
  • Includes hysteresis and activation delay features.
  • Three programming menus: set-point, calibration, and settings.
  • Three selectable relays for timer mode or additional set-point, plus one relay for alarm signals.
  • Fully programmable 4-20mA output.
  • Inputs for level probes, flow sensor, PT100 probe, and proximity switch.
  • Over dosing alarm and power supply of 230V 50-60Hz.
  • PVDF pump head, Viton® O-Ring, and ceramic valves.
  • Supplied with a complete installation kit including suction and discharge hoses.
Technical Specifications
  • Electromagnetic version with a standard kit including PP injection valve, PP foot filter, PVC suction tube, and PE discharge tube.
  • Flow rates: 2 l/h (0.53 US Gl/h) at 6 bar (87 PSI) and 5 l/h (1.52 US Gl/h) at 5 bar (72 PSI).
  • Standard power supply: 230V - 50-60 Hz with a power consumption of 65 Watts.
  • Net weight: 3.5 Kg.
Versions and Configurations
  • pH - pH Version: Setpoint at 7.2 pH, dosing mode ACID on both parameters.
  • pH - Rx Version: Setpoint at 7.2 pH (ACID) and 700mV (OXIDANT).
  • Cl - pH Version: Setpoint at 7.2 pH (ACID) and 0-2 ppm (DIRECT).
Overall Dimensions
Details on the overall dimensions are not provided in the text.
See more

Catalog excerpts

eTWIN PDE-1

eTWIN PDE Dosing and Regulation System for two parameters The eTwin is a compact, easy-to-use equipment consisting of two dosing pumps and two parameters controllers designed to measure pH, Redox and Chlorine plus the temperature. Mainly conceived for pool’s industry, the dosing pumps are available either in peristaltic and solenoid versions. General Features • • • • • • Backlighted graphic display, 5 keys keypad, Manual dosing (ON-OFF) 0 ÷ 120 pulses / minute Proportional dosing by self-regulation of the stroke frequency Flow rate up to 5 l/h and pressure up to 6 bar Measures available: pH-pH; pH-Rx; Cl-Ph Measurement range: ➢ pH 0 ÷ 14 ➢ Redox: - 1000 / + 1400 mV ➢ PPM: 0 – 2; 0 – 10, 0 – 20 e 0 - 200 ppm ➢ Temperature 0 – 100 °C (PT100) Hysteresis Activation delay when switched on 3 programming menus: set-point, calibration, settings. 3 relays completely selectable: on timer mode (weekly/daily) or as an additional set-point (including the temperature). 1 additional relay dedicated to alarm signals 4-20mA output fully programmable. Inputs: level probes; flow sensor; PT100 probe; proximity switch Over dosing alarm Power supply: 230V 50-60Hz*; PVDF Pump head O-Ring: Viton® Valves: Ceramic Supplied with complete installation kit: ➢ Suction hose: PVC Cristal® ➢ Discharge hose: Poliethylene *other power supplies upon request All Etwins PDE are supplied with a standard kit made up of PP injection

 Open the catalog to page 1
eTWIN PDE-2

TECHNICAL FEATURES Standard Power Supply (Volts -Hz) Power consumption (Watts) VERSIONS AND DEFAULT CONFIGURATION OVERALL DIMENSIONS Dosing mode: ACID Dosing mode: OXIDANT eTwin pH – Cl Dosing mode: ACID Dosing mode: DIRECT eTwin pH – pH Dosing mode: ACID on both parameters

 Open the catalog to page 2

All Etatron D.S. catalogs and technical brochures

  1. P Series

    3  Pages

  2. ST-P Series

    2  Pages

  3. D Series

    3  Pages

  4. ST-D Series

    2  Pages

  5. BT MF

    2  Pages

  6. BT pH-Rx-Cl/M

    2  Pages

  7. BT VFT

    2  Pages

  8. DLX MA/MB

    2  Pages

  9. DLX MA/AD

    2  Pages

  10. eOne PLUS

    2  Pages

  11. eOne MF

    2  Pages

  12. eOne MA

    2  Pages

  13. eOne BASIC

    2  Pages

  14. BT-BTB MA/M

    7  Pages

  15. BT MA/AD

    7  Pages

  16. PKX FT/A

    5  Pages

  17. DLX CC/M

    7  Pages

Archived catalogs

  1. PKX MA/A

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.