Short Circuit - ANSI Load Flow Motor Acceleration

Open the catalog to page 1
network_analysis - 2

Power System Enterprise Solution ETAP is the most comprehensive analysis platform for the design, simulation, operation, control, optimization, and automation of generation, transmission, distribution, and industrial power systems.

Open the catalog to page 2
network_analysis - 3

Cable Systems Customize ETAP to fit your needs, from small to large power systems ETAP Enterprise Suite provides one solution to your power system design, analysis, and operation needs. ETAP offers a comprehensive suite of analysis modules that can be configured to suit your specific needs. This modular approach allows you to purchase only the modules you need. Featured in this brochure Star Protective Devices Intelligent Load Shedding Base Package Cable Ampacity & Sizing Transmission Line Constants Report Manager Project Management Wizards Output Report Comparator Multi-Dimensional...

Open the catalog to page 3
network_analysis - 4

Instant Results, Comprehensive, Graphical Summary ANSI / IEEE Standards C37 & UL 489 Automatic Device Evaluation for Load Terminal Short Circuit Calculation Display Critical & Marginal Alerts Save hours of tedious hand calculations and take the guess- work out of short circuit studies by automating the process with multiple calculation and result analysis tools within ETAP. , The Short-Circuit module makes it easy to go from selecting elements from the comprehensive libraries of short circuit current ratings to performing dozens of different types of short circuit analysis with the purpose...

Open the catalog to page 4
network_analysis - 5

Device Duty Calculation & Evaluation for Single & Multiple-Phase Systems, Panel, & UPS Capabilities • Automatic 3-phase device evaluation • Device evaluation based on total or maximum through fault current ANSI and IEC standards are used for calculating short circuit current for parts of the network below main panels, subpanels, UPS, and phase adapters. Device duty calculation compares the calculated fault current from these networks for evaluation of protective devices and automatically generates critical and marginal alerts based on user-defined alarm limits. • Automatically adjust...

Open the catalog to page 5
network_analysis - 6

ANSI / IEEE Standards ANSI Short Circuit IEEE ggty- duty |gf • 1-phase & panel systems device evaluation • Determine maximum & minimum short circuit fault • Calculate V2 cycle, 1.5-4, & 30 cycle balanced • Check momentary & interrupting device capabilities • Check closing & latching capabilities • Evaluate symmetrical or total rated circuit breakers • Special handling of generator circuit breakers for system & generator faults • Interrupting duty as a function breaker contact parting time • Standard & user-definable contact parting time • Automatically includes No AC Decay (NACD) ratio •...

Open the catalog to page 6
network_analysis - 7

• -pole / 2-pole short circuit device duty for 1-phase 1 panel / UPS systems High-Voltage Switchgear and Controlgear, Part 100:High-Voltage Alternating-Current Circuit Breakers • nbalanced L-G, L-L, & L-L-G faults analysis U High-Voltage Switchgear and Controlgear, Part 200: AC Metal-Enclosed Switchgear and Controlgear for Rated Voltages Above 1 kV and up to and including 52 kV • ompares device ratings with calculated short C circuit values High-Voltage Switchgear and Controlgear, Part 203: Gas-Insulated Metal-Enclosed Switchgear for Rated Voltages Above 52 kV • ser-definable voltage C...

Open the catalog to page 7
network_analysis - 8

Load Flow Analysis One Program, One Database, One Solution Create & Validate System Models with Ease & Accuracy With ETAP’s advanced Load Flow module, you can create and validate your system model with ease and obtain accurate and reliable results. Built-in features like automatic device evaluation, summary alarms / warnings, result analyzer, and intelligent graphics make it the most efficient Load Flow program available today. Voltage Drop Power Factor Correction ETAP calculates bus voltages, branch power factors, currents, and power flows throughout the electrical system. ETAP allows for...

Open the catalog to page 8
network_analysis - 9

Most Efficient Load Flow Program Available Study Options • Option to update initial conditions • Phase-shifting transformers • Auto-adjust LTC / regulator settings • Power factor correction • Saves solution control parameters for each scenario • Make changes to your system & re-run studies instantly • Conduct unlimited “what if” studies within one database • Calculate bus voltages, currents, & power factors • Bus / transformer / cable reactor overload warnings • Calculate power flows • Update loading for DC load flow • Voltage drop calculations 3-Phase and 1-Phase Power Flow: Calculate...

Open the catalog to page 9
network_analysis - 10

Simultaneous Analysis of Different Scenarios Load Flow Result Analyzer ETAP Load Flow Result Analyzer is a time- saving tool that compares and analyzes multiple reports in a single view. You can compare the results of general information about a project or more specific information such as the load flow results for buses, branches, loads, or sources. ■ ] Load Fb* RtiuH Afutyztr Harmil LnaC jtu^d THCkVA • Understand results of multiple studies in one glance • Compare & view multiple load flow results in a single view • Analyze & compare reports from multiple projects • Create a base line...

Open the catalog to page 10
network_analysis - 11

Detailed Modeling with Accurate Results Features • ewton-Raphson, fast decoupled, & accelerated N Gauss Seidel • enerator governors with isochronous or droop mode G • enerator exciters with AVR or Mvar / PF controllers G • ransformer load tap changers (LTC / regulators) T • dvanced solution techniques for fast convergence A • ultiple loading conditions M • ultiple generation conditions M • wing, voltage regulated, & unregulated power sources S • oltage drop calculations V • oad forecasting L • lert view to display critical & marginal limit violations A • us / transformer / cable overload...

Open the catalog to page 11
network_analysis - 12

Motor Acceleration Intuitive, Intelligent, Incomparable Advanced Technology in Motor Evaluation & Simulation The Motor Acceleration module enables engineers to thoroughly evaluate the impact of load changes to electric power systems. Motor Acceleration is fully capable of starting one motor or transitioning an entire power system to another state. Sequence-start a series of machines using static or dynamic models, operate Motor Operated Valves (MOVs), and simulate the switching actions of Load Tap Changers. Advanced plotting and time varying graphical display enable engineers to quickly...