cable-systems
10Pages

{{requestButtons}}

Catalog excerpts

cable-systems - 1

Cable Sizing - Phase Cable Sizing - Grounding/PE Cable Ampacity Electric Shock Calculation Grounding & Earthing Color Themes Underground Thermal Analysis Cable Pulling

Open the catalog to page 1
cable-systems - 2

Power System Enterprise Solution ETAP is the most comprehensive analysis platform for the design, simulation, operation, control, optimization, and automation of generation, transmission, distribution, and industrial power systems.

Open the catalog to page 2
cable-systems - 3

Cable Systems Customize ETAP to fit your needs, from small to large power systems ETAP Enterprise Suite provides one solution to your power system design, analysis, and operation needs. ETAP offers a comprehensive suite of analysis modules that can be configured to suit your specific needs. This modular approach allows you to purchase only the modules you need. Featured in this brochure Star Protective Devices Intelligent Load Shedding Base Package Cable Ampacity & Sizing Transmission Line Constants Report Manager Project Management Wizards Output Report Comparator Multi-Dimensional...

Open the catalog to page 3
cable-systems - 4

Cable Systems Design, Operate, Expansion Powerful & Easy Tools for Cables Systems A Dynamic Approach to System ETAP Cable Systems help engineers design cable systems 1 to operate to their maximum potential while providing secure and reliable operation. The process is systematic and simple. ETAP contains Cable Thermal Analysis Software, Cable Pulling Software, automatic Cable Ampacity Software, Cable Phase and Grounding/PE Sizing Software, and Electric Shock Software calculations for a complete and wide solution for your cable system needs. Cable Sizing - Phase Cable Sizing - Grounding/PE...

Open the catalog to page 4
cable-systems - 5

Cable Sizing - Phase ETAP Cable Sizing for phase conductor provides various options which can be used as design requirements. These design requirements can be user-defined or automatically determined from load flow, short circuit, and protective device calculation results. • Cable load ampacity requirement based on operating current (Average or Phase Maximum), FLA of load, branch, or user- defined values • Maximum voltage drop requirement • Minimum starting voltage requirement for motor feeder cable • Short circuit requirement based on system calculation • Requirement to be compatible with...

Open the catalog to page 5
cable-systems - 6

Electric Shock Calculation ETAP Electric Shock calculation provides loop impedance and touch voltage calculation results which are compared with allowed values based on BS 7671, IEC 60364-4-41 or EN 50122. The calculation is for all types of earthing systems: TN-C, TN-C-S, TN-S, TT and IT. Electric Shock calculation considers a variety of design requirements. • Grounding/PE conductor in main cable • Auxiliary grounding/PE conductor • Armor and Structure effect • Overcurrent Protection and GFI/RCD effect • Local and source resistance to ground • First and second fault for IT (Individual, In...

Open the catalog to page 6
cable-systems - 7

Temperature Analysis Underground Thermal Analysis The Underground Cable Thermal Analysis module helps engineers to design cable systems to operate to their maximum potential while providing a secure and reliable operation. The advanced graphical interface allows for design of cable raceway systems to meet the existing and future needs by using precise calculations to determine the required cable sizes, their physical capabilities, and maximum derated ampacity. In addition, transient temperature analysis computes temperature profiles for cable currents, reducing the risk of damage to cable...

Open the catalog to page 7
cable-systems - 8

Detailed Modeling for Accurate Results Cable Pulling Accurate prediction of cable pulling forces is essential for the proper design of cable systems. This knowledge makes it possible to avoid under-estimated and/or over-conservative design practices to achieve substantial capital savings during construction. The Cable Pulling module accounts for multiple cables of different sizes and allows complex 3-D pulling path geometry. A point-by-point calculation method is performed at every conduit bends and pull points. Both the forward and reverse pulling tensions are calculated for determining...

Open the catalog to page 8
cable-systems - 9

Cable Installations Open/ Ventilated Embedded Direct Maintained Spacing Without Tray Top Cover Single Core Cable Muttl Core Cable Single Core Cable Multi Core Cable Thermal Insulation on One Side Open and Clipped Direct Building Voids Thermal Insulation On Wall or Suspended Flush Floor

Open the catalog to page 9
cable-systems - 10

Quality Assurance Commitment ETAP is Verified and Validated (V&V) against field results, real system measurements, established programs, and hand calculations to ensure its technical accuracy. Each release of ETAP undergoes a complete V&V process using thousands of test cases for each and every calculation module. ETAP Quality Assurance program is specifically dedicated to meeting the requirements of: 10 CFR 50 Appendix B ANSI/ASME N45.2 ANSI/IEEE 730.1 ANSI N45.22 O 2011 Operation Technology. Inc. All rights reserved. Certain names and/or logos used in this document may constitute...

Open the catalog to page 10

All Etap catalogs and technical brochures

  1. etap-product

    16 Pages

  2. Star / ARTTS

    20 Pages

  3. ETAP Real-Time

    20 Pages