1. Catalogs
  2. E.T.A. S.P.A.
  3. System of industrial air conditioning
video corpo

System of industrial air conditioning

System of industrial air conditioning
1 / 54 PagesView full catalog

System of industrial air conditioning

Product catalog summary
Introduction
The document provides an overview of ETA's industrial air conditioning systems, emphasizing their adaptability across various sectors. It includes a historical perspective on the company's growth and technological advancements in air conditioning.

Ethermo Range
This section details ETA's history, focusing on significant developments like the AR9000 cabinet and innovations such as E NUX and E COR. The emphasis is on merging technology with experience to deliver comprehensive solutions.

Business Sector
ETA's products are utilized in diverse industries, including automotive, packaging, oil & gas, logistics, HVAC, and marine sectors.

Air Conditioner Components
Key components of air conditioners are listed, including fans, thermostats, compressors, and evaporating batteries, highlighting their roles in temperature regulation and condensation prevention.

How to Compose the Code
This section guides on coding for heat exchangers and air conditioners, covering parameters like thermal conductivity and cooling power.

Air Conditioner Assembly
A step-by-step assembly guide is provided, stressing the importance of proper installation for efficient operation.

Our Solutions
ETA offers various air conditioning solutions, including indoor and outdoor models, with features like cooling capacity and protection degree.

General Features
ETA's air conditioners feature cooling capacities from 400 to 4000 W, high protection degrees, and materials resistant to environmental factors.

Certifications
Certifications such as CE, RoHS, and UKCA are mentioned, ensuring compliance with safety and environmental standards.
Specifications
The document outlines models with cooling capacities from 500 to 4000 W, protection degrees of IP65, and materials like stainless steel AISI 304L. They are designed for quick assembly and maintenance.

Procedures
Air conditioners are available in various mounting options and are designed for quick assembly and maintenance.

Standards and Norms
Compliance with NEMA standards and IP65 protection is mentioned, with options for IP66 upon request.

Recommendations
Optimal performance is achieved within a temperature range of 35°C, with resistance to -20°C to -40°C when a thermostat is installed.

Key Data from Tables
Tables list models with voltages, power wattages, and dimensions, such as ECD0515.WOE with 500 W power.

Critical Information
Air conditioners are designed for harsh conditions, with options for special materials like stainless steel AISI316L.
General Features
Specifications include cooling capacities of 800-1500 W and protection degrees from IP65 to IP66. Units are designed for easy maintenance and are resistant to temperatures from -20°C to -40°C.

Available Options
Special painting and stainless steel options are available. Units can be mounted externally or built-in.

Installation and Maintenance
A practical installation guide is provided, with easy maintenance features like a free condensing battery.

Technical Specifications
Models are listed with voltage/frequency, power, and dimensions. Air-to-air heat exchangers yield 17-55 W/k.

Certifications
Products are CE and cURus certified, with protection degrees of IP55 and IP65.

Contact Information
Contact details for ETA headquarters in Italy and branches in France, Poland, and the UK are provided.
See more

Catalog excerpts

System of industrial air conditioning-1

System of industrial air conditioning

 Open the catalog to page 1
System of industrial air conditioning-3

Our history Business sector Air conditioner components How to compose the code Air conditioner assembly ETHERMO RANGE ECD INDOOR RANGE Slim air conditioner Slim air conditioner cURus Wall-mounted air conditioner Wall-mounted air conditioner cURus Roof-mounted air conditioner Roof-mounted air conditioner cURus Practical guide for the air conditioner Filters Dissipator of condensation ECD OUTDOOR RANGE Door-mounted air conditioner cURus Wall-mounted air conditioner cURus Roof-mounted air conditioner cURus Practical guide for the air conditioner ESC INDOOR RANGE Air-to-air heat exchangers Air-to-air...

 Open the catalog to page 3
System of industrial air conditioning-4

THERMAL MANAGEMENT, AIR CONDITIONERS & AIR-TO-AIR HEAT EXCHANGERS ETA is History Family & Passion To provide an adequate air conditioning of the cabinet or air recirculation allows to optimize costs and times, preserving the optimal functioning of the electronic equipment. Our first successful cabinet AR9000 AR9000 ARETA ENUX AIR-CONDITIONING 1978 OUR HISTORY Antonio Turati’s heirs found ETA. Production work begins at the Castelmarte site The first numerically controlled machine is used. AR9000 is conceived, a very successful cabinet The new headquarters are built in Canzo Production of ARETA...

 Open the catalog to page 4
System of industrial air conditioning-5

Since 1978, E.T.A. SPA designs and manufactures high quality Enclosures for Industrial Automation, Harsh Environments, LV Energy Distribution and Information Technology. Our company’s goal is to combine technological innovation with the experience acquired over the years, in order to offer the customer not simply a product, but a product solution. Versatile stainless steel enclosures A solution suitable for IT business The ETA handle wins honourable mention for the Compasso d’Oro by ADI The new R&D department ETA Next is born A solution for industrial electronics The new systems The new ETA designed...

 Open the catalog to page 5
System of industrial air conditioning-6

ECD INDOOR RANGE ECD OUTDOOR RANGE ECS INDOOR RANGE BUSINESS SECTOR Air conditioners or heat exchangers are used and installed for the construction of complex industrial plants with different applications: 1.AUTOMOTIVE 2.PACKAGING 3.OIL & GAS 4. HANDLING & LOGISTIC 5. HVAC 6. MARINE & OFFSHORE ECD INDOOR RANGE ECD OUTDOOR RANGE ECS INDOOR RANGE ECD INDOOR RANGE ECD OUTDOOR RANGE ECS INDOOR RANGE

 Open the catalog to page 6
System of industrial air conditioning-7

ECD INDOOR RANGE ECD OUTDOOR RANGE ECS INDOOR RANGE ECD INDOOR RANGE ECD OUTDOOR RANGE ECS INDOOR RANGE ECD INDOOR RANGE ECD OUTDOOR RANGE ECS INDOOR RANGE

 Open the catalog to page 7
System of industrial air conditioning-8

It has the task of maintaining an homogeneous temperature inside the electrical panel. Calibrated to 35 ºC, it ensures the correct operation of the air conditioner and the electronics present in the cabinet, avoiding condensation;it is therefore an indispensable operating parameter and warranty clause. It has the function and purpose of compressing the refrigerant gas. It therefore allows the movement of the gas within the circuit. CONDENSING BATTERY It is part of the external unit of the air conditioner and serves to dissipate heat. DEHYDRATOR FILTER Liquid gas passes through the filter dehydrator...

 Open the catalog to page 8
System of industrial air conditioning-9

INTERNAL SIDE (COLD) CONDESING BATTERY DEHYDRATOR FILTER CAPILLARY TUBE (EXIT)

 Open the catalog to page 9
System of industrial air conditioning-10

AIR CONDITIONERS, HOW TO COMPOSE THE CODE ETA Product range CONDITIONERS CD = air conditioners Volt/ Frequency Extra application Product version .W = WALL .R = ROOF .D = EXTRA SMALL U = cURus O= OUTDOOR cURus NO LETTER ( )*= INDOOR E = EXTERNAL I = RECESSED P = PARTIAL EXTERNAL S = SEMI RECESSED HEAT EXCHANGERS, HOW TO COMPOSE THE CODE Thermal Volt/ Product range – HEAT conductivity Frequency W/k EXCHANGERS SC = heat exchangers Extra application Product version .AA = U = cURus E = EXTERNAL AIR-TO-AIR

 Open the catalog to page 10
System of industrial air conditioning-11

* MOUNTING TYPE EXTERNAL MOUNTED A EXTERNAL PARTIALLY MOUNTED A SEMI BUILT-IN MOUNTED EXTERNAL PARTIALLY SEMI BUILT-IN

 Open the catalog to page 11
System of industrial air conditioning-12

DRILLING TEMPLATE A. AIR CONDITIONER/ AIR-AIR EXCHANGER B. GASKET C. DRILLING TEMPLATE

 Open the catalog to page 12
System of industrial air conditioning-13

EXAMPLE OF AN AIR CONDITIONER ASSEMBLY 1 1.Remove the assembly screws from the cover 2.Apply the gasket on the air conditioner back and remove the assembly screws from the pallet 3.Remove the air conditioner from the pallet 4.House the air conditioner on the door and attach it to the carpentry 5.Fit the cover on the air conditioner and fix it. 6.Assemply completed

 Open the catalog to page 13
System of industrial air conditioning-15

WHY YOUR ENCLOSURE NEED AN AIR CONDITIONER One of the biggest enemies of expensive electronic components is heat. Current technologies have allowed us to develop products that dissipate less energy, but to counter this positive aspect of the research there is the increase in the number of components that are inserted inside the control cabinets. So how can cooling take place? HOW COOLING TAKE PLACE Through the walls of the cabinet, through convention or with positive temperature difference Difference between Ti > Te Ti = Desired max. temperature inside the cabinet Te = Desired max. temperature...

 Open the catalog to page 15
System of industrial air conditioning-17

OUR SOLUTIONS ECD INDOOR RANGE SLIM AIR CONDITIONER SLIM AIR CONDITIONER cURus WALL-MOUNTED AIR CONDITIONER WALL-MOUNTED AIR CONDITIONER cURus ROOF-MOUNTED AIR CONDITIONER ROOF-MOUNTED AIR CONDITIONER cURus ECD OUTDOOR RANGE WALL-MOUNTED AIR CONDITIONER cURus DOOR-MOUNTED AIR CONDITIONER cURus ROOF-MOUNTED AIR CONDITIONER cURus ESC OUTDOOR RANGE AIR-TO-AIR HEAT EXCHANGERS AIR-TO-AIR HEAT EXCHANGERS cURus They are certified as follow: The CE mark certifies that the product complies with the requirements established by the European Union in terms of safety, health and environmental protection Certification...

 Open the catalog to page 17
System of industrial air conditioning-19

INDOOR RANGE The range of air conditioners designed for INDOOR installations includes products • Designed to ensure optimal operating conditions for electrical and electronic equipment • Suitable for applications where a set point temperature lower than the ambient temperature is required Various types of assembly to satisfy every type of application including: • Door applications • Wall applications • Roof applications • Different power supplies available • High protection degree cabinet side • CE certified (and cURus certified on

 Open the catalog to page 19

All E.T.A. S.P.A. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.