Overview: The TSD-100 is a large-capacity two-zone thermal shock chamber by ESPEC, designed to meet international test standards such as MIL, IEC, and JASO. It features a 100L test area, suitable for research, development, and production applications.
Specifications: The chamber operates within a high temperature range of +60 to +200℃ and a low range of -65 to 0℃, with a temperature fluctuation of ±1.0℃. It uses a mechanical cascade refrigeration system and measures W1100×H1885×D1965 mm, weighing approximately 1100 kg.
Performance: The TSD-100 enhances temperature uniformity and reduces test time by transferring the test area between high and low temperature chambers. It includes a Specimen Temperature Trigger (STT) for precise monitoring and reduced pretesting time.
Utility Features: Features include a 100L capacity, "Soft-move mode" for smooth specimen transfer, an anti-drop mechanism, easy wiring access, and an optional viewing window.
Control and Operation: Equipped with a color LCD touch-screen for simplified operation, it includes PID control, temperature attainment control, and automatic defrost functions.
Eco-friendly Features: The TSD-100 reduces power consumption by 30% compared to previous models and includes material labeling for recycling. Optional paperless recorders are available for temperature recording.
Test Standards Compatibility: Compatible with IEC, MIL-STD, and JASO standards, detailing specific temperature settings, recovery times, and cycle numbers.
Specifications and Requirements: A regulator valve is needed if pressure exceeds 0.5MPa. Measurements should follow ISO 1996-1: 2003 standards for sound pressure levels.
Safety Devices: Includes leakage breakers, circuit breakers, overheat protection switches, and door switches for safe operation.
Accessories: Includes specimen baskets, shelf brackets, cartridge fuses, and thermocouples, essential for proper functioning and maintenance.
Safety Precautions: Users should avoid using explosive, flammable, or corrosive substances. The operation manual should be read thoroughly to prevent risks.
Options: Optional features include temperature recorders, auxiliary cooling injectors, and additional overheat protectors.
Communication and Interface: Supports RS-232C and GPIB interfaces, with options for external alarm terminals and communication cables.
Quality and Compliance: ESPEC CORP. is ISO 9001:2008 registered, ensuring quality management standards. Specifications may change due to design improvements.
Contact Information: Contact details for ESPEC's global offices are provided, including locations in North America, Europe, China, and Southeast Asia.
See more

Catalog excerpts

Thermal Shock Chamber TSD-100-1

Quality is more than a word

 Open the catalog to page 1
Thermal Shock Chamber TSD-100-2

Large-capacity two-zone chamber capable of exposing specimens to a uniform thermal stress. Two-zone thermal shock chamber ideally suited for Japanese and international test standards such as MIL, IEC or JASO . With its 100L test area, and its outstanding thermal uniformity characteristics, the TSD Thermal Shock Chamber from ESPEC can test specimens under a uniform thermal stress, and is ideally suitable for a wide range of applications, from research and development to inspection or production.

 Open the catalog to page 2
Thermal Shock Chamber TSD-100-3

*The viewing window, paperless recorder and additional overheat protector are optional.

 Open the catalog to page 3
Thermal Shock Chamber TSD-100-4

Performance Meeting the high performance required by today's test standards Specimen temperature recovery (example) (based on MIL-STD-883 condition C) Test conditions Temperature uniformity measurement method High temp. exposure: 155 for 30 min. Thermocouples were embedded in 10 ICs Low temp. exposure: 68 for 30 min. placed on two levels in each of the corners Specimens: ICs, 10 kg and in the center of a specimen basket. (Specimens with embedded thermocouples were placed beneath other ICs.) Temperature recovery time shortened with the two-zone system During testing of 10 kg of plastic molded...

 Open the catalog to page 4
Thermal Shock Chamber TSD-100-5

Utility Boast of a 100L capacity Featuring a 100L test area capacity, the chamber dramatically increases the processing capabilities and even allows to test A4-size printed circuit boards laid flat at once. Smooth specimen transfer The “Soft-move mode” is used to reduce vibration shocks when specimens are movi ng bet ween the high and low temperature chambers. Test area anti-drop mechanism to protect specimens A braking system fitted to the drive mechanism prevents specimens from falling into the test area when the chamber stops operation. Test areas top: high temperature chamber bottom: low...

 Open the catalog to page 5
Thermal Shock Chamber TSD-100-6

Control operation Color LCD interactive touch-screen system Operation and settings simplified by the use of a touch-screen LCD display (instructions displayed on-screen). At-aglance confirmation of test patterns, test area temperatures, temperature cycles, upstream/ downstream control, and trend graph displays. Door-mounted instrumentation Instrumentation including the touchscreen controller is incorporated into the door. It reduces the overall footprint and frees up both sides of the chamber for easy access. Setting Instrumentation Interactive key input by touch panel Test area: exposure temp....

 Open the catalog to page 6
Thermal Shock Chamber TSD-100-7

NSTRUMENTATION PANEL •Test detail monitor Test details are displayed while the Product sensor settings Possibility to enable or disable the specimen temperature sensor Same procedure for additional optional specimen temperature •Test setting Displays the conditions to define Service guide If an inspection item is selected. maintenance steps appears. This is useful before proceeding with tests or to assist during periodic Detailed description Details the regular inspection ■f tl.cf niH±lld! Hf E.HL'lt HTLl

 Open the catalog to page 7
Thermal Shock Chamber TSD-100-8

Eco-friendly A whole range of environmentally-friendly features Reduced power consumption Reducing power consumption is an important issue for our customers. The TSD-100 employs number of measures, such as the use of electronic expansion valves to regulate the refrigeration capacity control, and thus reduce overall power consumption by 30% (compared to previous ESPEC models). Material labeling for easy recycling Built-in paperless recorder (option) *Rear side, on the right Plastic molded components are labeled and easily detachable to make recycling easier duning future disposal of the equipment....

 Open the catalog to page 8
Thermal Shock Chamber TSD-100-11

TEST STANDARD (TSD-100 COMPATIBILITY) Temperature setting Test standard High temp. ( Specimen less than 15 min. 10 min. or longer after transition start 15g and below: 15 to 150g: 150 to 1,500g: More than 1,500g: Within 5 min. after solder joint temp. reaches ±2℃ of preset temp. Or, 0.2kg and below: 0.5 hours 0.2 to 0.8kg: 1 hour 0.8 to 1.5kg: 1.5 hours More than 1.5kg: 2 hours preset temp Depends on parties involved 0.2kg and below: 0.2 to 0.8kg: 0.8 to 1.5kg: More than 1.5kg: Depends on parties involved Max. storage temp. Min. storage temp. Air 5 min. or 10 of soak time, whichever is longer...

 Open the catalog to page 11
Thermal Shock Chamber TSD-100-12

SPECIFICATIONS Model 2-zone transition by vertical transfer of specimens High temp. exposure range Test area Low temp. exposure range Temp. uctuation Pre-heat upper limit Cold chamber Pre-cool lower limit Temp. pull down time *2 2-zone High temp. exposure: Low temp. exposure: Power supply voltage: Sensor position: Specimen: Recovery conditions 150 *3 30 min. 65 *3 30 min. rated voltage downstream Plastic molded ICs, 10kg Specimen IC temp. within 15 min. High temp. exposure: Ambient temp.: Power supply voltage: Specimen: Recovery conditions Ambient temp. recovery time 150 to max. 55 23 rated voltage...

 Open the catalog to page 12
Thermal Shock Chamber TSD-100-13

SAFETY DEVICES • Leakage breaker (200, 220, 380V AC) • Specimen basket • Circuit breaker (208, 400/415V AC) (18-8 Cr-Ni stainless steel: 5 mesh metal basket) • Electrical compartment door switch W700 x H40 x 0410 mm/ load capacity 5kg 2 • Hot chamber overheat protection switch * Shelf brackets 2 sets • Cold chamber overheat protection switch * Cartridge fuse (1A, 7A, 10A, 15A) 4 • Hot chamber overheat protectors * Cable Port rubber Plu9 2 (Built into temperature controller) • Perforated cable port cap 1 • Cold chamber overheat/ overcool protectors • Wire fisher (specimen wiring tool) 1 (Built...

 Open the catalog to page 13
Thermal Shock Chamber TSD-100-14

OPTIONS Paperless recorder Records temperature of each section such as the temperature inside the chamber. Select either built-in or portable type. Built-in type Number of inputs (Initial setting): PL1S: 1 (5 more channels can be turned ON) Data saving cycle: 1 sec PL3S: 3 (3 more channels can be turned ON) Data saving cycle: 1 sec PL3L: 3 (3 more channels can be turned ON) Data saving cycle: 5 sec PL5S: 5 (1 more channels can be turned ON) Data saving cycle: 1 sec PL5L: 5 (1 more channels can be turned ON) Data saving cycle: 5 sec PL6S: 6 Data saving cycle: 1 sec PL6L: 6 Data saving cycle: 5...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.