Liquid to Liquid Thermal Shock Chamber
10Pages

{{requestButtons}}

Catalog excerpts

Liquid to Liquid Thermal Shock Chamber - 1

Quality is more than a word

Open the catalog to page 1
Liquid to Liquid Thermal Shock Chamber - 2

Key technology for ensuring reliability Supports the current trend toward higher stress. High accuracy is increasingly demanded in the pursuit of reliability in the field of electronics. “Liquid-to-liquid” type thermal shock testing is now attracting attention for its ability to impose higher thermal stress on specimens than “air-to-air” type testing, and to deliver test results quickly. ESPEC has successfully developed next-generation liquid-to-liquid thermal shock chambers that satisfy the demand for environmental conservation and lower running costs from brine and power consumption,...

Open the catalog to page 2
Liquid to Liquid Thermal Shock Chamber - 3

Utility A number of mechanisms for drastically reducing brine consumption To reduce br i ne consu mpt ion, t he airtightness of the test area has been enhanced to prevent vapor leakage and brine evaporation. Numerous mechanisms have also been adopted, including a water separation filter for removing brine from water for the purpose of brine recycling. As a result, these new chamber models have reduced brine consumption by approximately 65 compared to the preceding model (TSB-5). Both single-liquid and double-liquid brine applicable Either single-liquid brine or doubleliquid brine can be...

Open the catalog to page 3
Liquid to Liquid Thermal Shock Chamber - 4

Comparison of power consumption Conditions : 20 cycles H : 155 L : 70 Specimen : TSB-51 TSB-5 Energy savings achieved Dramatic energy savings have been achieved through the adoption of a new r ef r ige r a t io n c i r c u it , w it h p owe r consumption slashed by as much as 52 (compared to former ESPEC models). 10.0 *Above values are references. Installation environment improved through reduced operation noise 20.0 The operation noise level of the chamber has been reduced to as low as 65 dB (A-characteristic) by providing soundproofing panels for the noise-emitting machine compartment,...

Open the catalog to page 4
Liquid to Liquid Thermal Shock Chamber - 5

Control operation Visibility and ease of use improved through interactive input using a touch-screen system and color LCD screen Uses a color LCD interactive touchpanel system employed throughout the Thermal Shock Chamber Series A color LCD panel design allows settings to be made simply by touching the screen in accordance with the display. The test pattern, test area temperature, number of temperature cycles, trendgraph display, etc., are all displayed on the screen. Setting system Interactive input system using a touch panel Color TFT LCD panel (6.5 inch) • Test area exposure temperature...

Open the catalog to page 5
Liquid to Liquid Thermal Shock Chamber - 6

SPECIFICATIONS Model Two-liquid bath system with specimen basket transfer Single-liquid or double-liquid uorine deactivated brine Utility requirement System Power supply (within 10% of the rated voltage) Maximum load current Operating temperature Air-source pneumatic pressure Temp. pull-down rate *3 Ambient temp. to Cold bath Liquid temp. Exposure time 15 cycles Plastic molded ICs 1.0kg Within 10 sec. (Time of transfer between hot and cold baths) Exterior material Painted steel Internal tank Stainless steel plate (18-8 Cr-Ni) Glass wool, foamed polyurethane Sheathed heater Cooler...

Open the catalog to page 6
Liquid to Liquid Thermal Shock Chamber - 7

TEST STANDARDS (satisfied by all models in the TSB Series) Test Standard Test Condition Exposure Temperature High Temp. Ambient Temp. Exposure Time 2 −10 Varies by specimen weight Less than 1.4 g: 0.5 min. 1.4 to 14 g: 0 2 min. −10 Over 14 to 140 g: 5 min. Temperature Test Number of Recovery Starting Test Cycles Ambient Time Point Temp. Temperature of the specimen under worstcase conditions, recovered within 5 min. Low temp. or high temp. 5 cycles 15 cycles 25 cycles 10 cycles unless otherwise Low temp. specied

Open the catalog to page 7
Liquid to Liquid Thermal Shock Chamber - 8

SAFETY DEVICES Leakage breaker Circuit breaker for wiring Motor reverse prevention relay Compressor thermal relay Compressor temperature switch Electric parts compartment door switch Specimen transfer area door switch Recycling circuit fan temperature switch Refrigerator high-pressure switch Hot bath agitator temperature switch Cold bath agitator temperature switch Air-pressure switch Hot bath boil-dry protector Cold bath boil-dry protector Overheat protector for hot bath Overcool protector for cold bath Overheat/ overcool protector for the hot bath (built into the controller) Overheat/...

Open the catalog to page 8
Liquid to Liquid Thermal Shock Chamber - 9

OPTIONS Paperless recorder Records temperature of each section such as the temperature inside the chamber. Number of inputs: PL1S: 1 (5 more channels can be turned ON) Data saving cycle: 1 sec PL3S: 3 (3 more channels can be turned ON) Data saving cycle: 1 sec PL3L: 3 (3 more channels can be turned ON) Data saving cycle: 5 sec Temperature range: 100 to 220 External recording media : CF memory card (128 MB) Language support: ENG, JPN Used to measure specimen temperature, etc. T JIS C 1602 with ball attached Equipped when there is no air supply source. Specimen basket Temperature recorder...

Open the catalog to page 9
Liquid to Liquid Thermal Shock Chamber - 10

ESPEC CORP. Head Office 3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan ESPEC NORTH AMERICA, INC. ESPEC EUROPE GmbH ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD. Head Office BEIJING Branch TIANJIN Branch GUANGZHOU Branch SHENZHEN Branch SUZHOU Branch ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD. Quality Management System Assessed ESPEC CORP. has been assessed by and registered in the Quality Management System based on the International Standard ISO Japanese Standards Association (JSA). Environmental Management System ESPEC CORP W3E22C02 (The contents of this catalog is as of March,...

Open the catalog to page 10

All ESPEC catalogs and technical brochures

  1. Vacuum Ovens

    16 Pages

Archived catalogs