Catalog excerpts
High-performance Clean Oven PVHC|232MS¥332MS PV(H)C|212¥232¥332 CAT.No.E87197-U903
Open the catalog to page 1Ideal for heat treatment requiring air condition of Class 5 cleanliness. The high cleanliness is assured during the temperature heat-up and pull-down. ESPEC's Clean Ovens are used extensively for heat treatment of specimens and drying components in stringent clean air requirements of Class 5 cleanliness. A space-saving upright design, and a large LED display for improved visibility are some of the user-friendly features. Eight models to choose from, including high-performance models which ensure automated operation and dedicated cleanliness even throughout temperature heat-up or cooling...
Open the catalog to page 23 Utility Fan Heater HEPA filter Door œ Horizontal laminar circulation system Class 5 cleanliness level Class 5 cleanliness level is achieved by employing HEPA filters and a back-tofront horizontal laminar circulation system which produces uniform hightemperature airflow. Distance of airflow in the chamber is shortened, resulting in smooth air delivery in between specimens and uniform heat treatment. Additionally, it prevents dust generated from specimens placed upstream from flowing downstream. The upright design with instrumentation, heater, and other mechanisms gathered on the upper side...
Open the catalog to page 44 Automated operation throughout heat treatment process (High-performance model) An automatic damper is provided as standard for automation in all processes from temperature heat-up to heat treatment and temperature pull-down. To reduce pulldown time, an optional external atmosphere introducing blower forces air into the chamber to supple-ment cooling. High level of cleanliness during temperature heat-up and pull-down (High-performance model) The high-performance model delivers dedicated cleanliness throughout wide temperature ranges by employing HEPA filters which provide stable filtering...
Open the catalog to page 55 Control operation œ Alarm œ Constant operation mode User-friendly Standard Instrumentation Standard Instrumentation features programmed operation with operational settings such as constant mode and automatic start/stop. Suitable for heat treatment, drying, and similar productionline applications. M-Instrumentation features programs with up to 20 steps Suitable for a range of applications from temperature-characteristics testing to heat treatment and drying. Programmed operation now allows storing ten patterns, each up to twenty steps. Provides a wide range of functions, including...
Open the catalog to page 6Time Time Time 1.HOLD 2.CONST 3.OFF END END END Example of programmed operation (M-Instrumentation) Step program* Ramp program* Automatic start* End of program Temp. Time Time Time Temp. Temp. Temp. Temp. Temp. – Temperature at the final step is maintained. Operation at preset constant temperature. Oven is turned OFF The number of repetitions of a program can be preset between 1 and 999. Stepwise damper setting is possible. (optional automatic damper required for PVC/PVHC). Guarantee soak function can be set, whereby the timer is activated upon achieving set temperature. ‡@ ‡A ‡B ‡C ‡D ‡E...
Open the catalog to page 77 SPECIFICATIONS SAFETY DEVICES œDo not use specimens which are explosive or inflammable, or which contain such substances. To do so could be hazardous, as this may lead to fire or explosion. œDo not place corrosive materials in the chamber. If corrosive substances or humidifying water is used, the life of the unit may be significantly shortened. Be sure to read the user’s manual before operation. CAUTION DANGER œDo not use specimens which are explosive or inflammable, or which contain such substances. To do so could be hazardous, as this may lead to fire or explosion. œDo not place...
Open the catalog to page 8Modification for clean-room compatibility Pre-filter Removes large particles from external air. Recommended when installing the oven in a location other than a clean room. (for oven with damper) E Where located: Air intake on rear of chamber O2 concentration indication adjuster This controls the oxygen concentration inside the oven. EOxygen concentration range @5%-15% oxygen concentration (v/v) * Without damper EInjection gas @N2 gas (Normal temperature, dry gas) * Except PVHC-232MS/332MS Nitrogen gas injector Exhaust port flange Flange for discharging hot air from the oven. Installed on...
Open the catalog to page 9OPTIONS Integrating hour meter Calendar timer Automatically starts and stops chamber operation. Setting range: Sunday to Saturday (Possible to set multiple days) 0:00 to 23:59 (Setting resolution 1 minute) Margin of error per month: ±1 minute Time-up output signal 9 Outputs contact signals at the end of programmed operation. Power supply capacity 250V AC 1A Action: Outputs "close" contact output after time-up Where located: Right side of chamber Paperless recorder Records temperature inside the chamber. Additional inputs may also be recorded. Temperature range: 0 to {200Ž 0 to {300Ž 0 to...
Open the catalog to page 10OPTIONS E‹Lx˜^teŒvrniaƒfl aƒWlaƒ^rmƒ‹ tjerminal Outputs alarm signals. EOutput point: 1 point EPower supply capacity: 250V AC 1A EContact output at“close” @in an emergency. EWhere located: Right side E‹Lm˜^eŒvrgieƒfncƒWy ƒ^stƒ‹opj switch Shelf and shelf bracket Equivalent to those suppl ied as accessories. Power cable If the standard 2m is not long enough, 5m and 10m cables are available. Stand EExterior @Cold rolled and rust-proof steel plate @with melamine baked finish. Fixture for securiug body Used to bolt the chamber to the floor. Mesh shelf For testing small specimens. Material: 18-8...
Open the catalog to page 11œSpecifications are subject to change without notice due to design improvements. œCorporate names and trade names mentioned in this catalog are trademarks or registered trademarks. œPrinted on recycled paper. W3E21C02 (The contents of this catalog is as of March, 2009.) ESPEC CORP. has been assessed by and registered in the Quality Management System based on the International Standard ISO 9001:2000 (JIS Q 9001:2000) through the Japanese Standards Association (JSA). ESPEC GROUP ESPEC CORP. ESPEC ENGINEERING CORP. ESPEC TEST CENTER CORP. Head Office 3-5-6, Tenjinbashi, Kita-ku, Osaka...
Open the catalog to page 12All ESPEC catalogs and technical brochures
-
TDDB Evaluation System
8 Pages
-
High-performance Clean Oven
12 Pages
-
Thermal Shock Chamber (TSD-100)
16 Pages
-
Constant Climate Cabinet
8 Pages
-
Platinous J Series
40 Pages
-
Thermal Shock Chamber TSA series
24 Pages
-
Vacuum Ovens
16 Pages