CAN-CBX-REL4/2CANopen® Module with 2 Change-over and 2 Make Relay Contacts Switching Relays reliably via CANopen and CAN • Switch loads easily as a change-over switch and normally open (make) contact • Reliably switch up to 8 A up to 100,000 times • Suitable for use in all areas with the wide temperature range from -20°C to +60°C CANopen® Integration according to CiA® Specifications • Robust CANopen communication according to CiA specifications • Compatibility and interoperability with CiA 301 CANopen application layer and communication profile ensured • Generic I/O-module providing versatile integration capabilities with CiA 401 CANopen profile for I/O devices Extended Switching and Error Functions • Simultaneous switching of up to 32 relays with one PDO / CAN frame • Automatic switchover to the specified state in the event of system errors Easy to combine with other Modules of esd’s CBX Series • E.g. Modules for analog inputs or outputs. Reliable Relay Outputs The CAN-CBX-REL4/2 is equipped with 4 relays which are electrically isolated from each other. Therefore, various voltages can be applied to the CAN-CBX-REL4/2 simultaneously. High-Speed CAN Interface The module features a High-Speed CAN interface compliant with ISO11898 standards. It offers electrical isolation and supports bit rates up to 1 Mbit/s. CANopen node number and the CAN bit rate are configured conveniently via coding switches. Efficient I/O Integration Within the CBX module series, the InRailBus technology offers compact industrial CAN input/output modules. These modules feature an efficient wiring concept for CAN and supply voltage and are housed in a slim design that focuses on usability. Advanced InRailBus Integration The InRailBus connector (TBUS connector) simplifies the supply of power and CAN bus signals. It is seamlessly integrated into the DIN rail for user-friendly installation. At the same time, individual modules can be removed from the InRailBus without interrupting the bus signals, which enables efficient maintenance. Alternatively, power and signals can also be connected separately via the terminal connections. Comprehensive LED Status Display Each relay has a dedicated LED that indicates the current state, while four additional LEDs clearly visualize the status of the CANopen node and I/O errors. Tailored Solutions upon Request We offer customization options to meet your specific needs. For detailed information, kindly reach out to our sales team. CANCANTechnical Specifications: Relay Specification: Number of outputs 4 outputs: 2x normally open, 2x change-over Switching voltage Max. 250 VAC, 125 VDC Switching power Max. resistive load: 2000 VAJ240 W _Max. inductive load: 875 VA/170 W_ Switching frequency Max. 30 operations per minute Durability Endurance mechanical load: 100 000 cycles CAN interface Physical layer according to CAN bit rate: 10 kbit/s up to 1 Mbit/s Protocol CANopen according to CiA specifications Power supply voltage 12 V DC... 32 V DC/ Imax_24v= 100 mA Ambient temperature -20 °C... +60 °C Dimensions 22.5 mm x 99 mm x 114.5 mm (without connectors) Housing Plastic housing (ME MAX) for carrier rail Connectors Power: Phoenix MSTBO2,5/4-G1LKMGY Order Information: CAN-CBX-REL4/2 CANopen module with 4 relay outputs C.3012.04 CAN-Cable-S 0.3m (plug) Cable, 0.3 m, pin contacts C.1323.03 CAN-CBX-TBus Mounting-rail bus connector C.3000.01 ©2024 esd electronics gmbh, Hannover File: CAN-CBX-REL4-2_Datasheet_en_12.docx All data are subject to change without prior notice. CiA® and CANopen® are registered EU trademarks of CAN in Automation e. V.. Rev.: 1.2 • Date: 2024-09-23 All trademarks are reserved by their respective owners. 30165 Hannover/Germany E-mail: [email protected]
Open the catalog to page 12 Pages
1 Page
1 Page
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
56 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
1 Page