Catalog excerpts
Cradle for Beautiful Cells
Open the catalog to page 1Welcome to Esco Welcome to Esco Esco’s Vision is to provide enabling technologies for scientific discoveries to make human lives healthier and safer. The Esco Lifesciences Group is committed to deliver innovative solutions for the clinical, life sciences, research, industrial, laboratory, pharmaceutical, and IVF community. With the most extensive product line in the industry, Esco have passed a number of international standards and certifications. Esco represents innovation and forward-thinking designs, that are of the highest standard quality since 1978. Availability and Accessibility....
Open the catalog to page 2Products and Application Laboratory Equipment Sample Handling and Preparation • Class I Biological Safety Cabinets • Class II Biological Safety Cabinets • Class II Type A2 Biological Safety Cabinets • Class II Type B1 Biological Safety Cabinets • Class II Type B2 Biological Safety Cabinets • Class III Biological Safety Cabinets • Horizontal Laminar Flow Cabinets • Vertical Laminar Flow Cabinets • Laboratory Animal Research Workstations • Laboratory Centrifuges Sample Cultivation • CO2 Incubators, Direct Heat Air-Jacketed • CO2 Incubators with Cooling System • CO2 Incubators with High Heat...
Open the catalog to page 3CelMate® CO2 Incubators INTRODUCTION Esco now offers the new CelMate®, 50 L, 170 L, and 240 L, entry-level cell culture CO2 incubator with superb contamination control. It is specifically designed for laboratories looking for a cost-effective CO2 incubator that can provide the best protection for their cell culture. Sleek, reliable, and intuitive, Esco CelMate® CO2 incubators provide all-rounded sample protection that brings your scientific dreams one step closer to reality. KEY FEATURES CelMate® CO2 INCUBATORS Cradle for Beautiful Cells Perforated shelving to improve uniformity Anti-tip...
Open the catalog to page 4ULPA FILTER • 99.999% efficient, superior to conventional HEPA filters • Filters air continuously • Chamber returns to ISO Class 5 cleanliness in 11 minutes upon door closing to prevent contamination • Heat-resistant IR sensor • Single-beam, dual-wavelength IR sensor is drift-free • Auto-zeroing DOOR SWITCH Automatically turns off the blower, heater, UV, and gas supply when the door is opened TOP COVER Provides quick access to electrical panel components SMARTSENSE TM MICROCONTROLLER INTERFACE Intuitive, fully equipped control and monitoring system BLOWER* Gentle airflow in chamber improves...
Open the catalog to page 5VIVOCELL™ PRECISE PARAMETER CONTROL BEST UNIFORMITY AND CONTROL AMONG THE COMPETITION 37.4 Time (minutes) Different lines represent different sensor positions inside the chamber. Esco CelMate® has uniformity variance of less than ± 0.5 oC which means all the samples are evenly heated.* Minimal fluctuation (± 0.2 oC) ensures temperature stability.* FAST CO2, TEMPERATURE AND HUMIDITY RECOVERY WITHOUT OVERSHOOT 6 Precisely-tuned sensor and software result in fast recovery of CO2 without overshoot. This ensures uniform CO2 levels even with frequent incubator door opening. Recovery of both...
Open the catalog to page 6ROBUST CONTAMINATION CONTROL STERISAFE™ ULPA FILTRATION SYSTEM • Chamber air is continuously filtered by ULPA filters to keep the chamber at ISO Class 5 cleanliness. This ensures that all contaminants from both room air and chamber air are filtered, thus only clean air is recirculated. • ULPA filters operate at 99.999% efficiency, superior to conventional HEPA filters which are 99.99% efficient. • Chamber achieves ISO Class 5 cleanliness 11 minutes after door closing.* *Units were factory-tested under controlled environmental conditions per DIN 12880 standard and Esco method. Esco does not...
Open the catalog to page 7CONTROLLER TYPE USER - FRIENDLY SOFTWARE INTERFACE 2 • Comprehensive, user-configurable alarms: - Temperature - CO2 - Humidity (if installed) • CelAlert™ alarm system reminds user to replace parts. In addition to CO2 tank low alarm, CelAlert™ has CO2 tank depletion reminder that automatically calculates how much CO2 gas is left in the tank and alerts user to replace the tank one week before the gas is depleted. This gives the user some buffer time to place orders for new tanks. 1. Start / stop decontamination cycle ULPA reminder will alert user to replace ULPA filter. 2. HEAT LED 9. INJECT...
Open the catalog to page 8Prevents the electrical panel from overheating. Power Supply Inlet Connects the incubator unit to the power source. Provides serial communication port for PC. It can be daisy-chained from one product to another and can also be connected to a PC Analog Port (Optional) Allows the incubator to output analog signals representing temperature, CO 2/O 2 concentration and relative humidity, depending on the options available in the incubator. This allows the incubator to be connected to an inhouse data acquisition or alarm system. Alarm Contact A set of relay contacts located on the rear panel of...
Open the catalog to page 9ORDERING INFORMATION IR SENSOR MODEL WITH STAINLESS STEEL CHAMBER MODELS ITEM CODE CelMate Incubator 50 L, IR Sensor, CO2 Control, Moist Heat Decon, 230 VAC, 50/60 Hz (Without Decon Pump) CelMate® Incubator 50 L, IR Sensor, CO2 Control, Moist Heat Decon, 115 VAC, 50/60 Hz (Without Decon Pump) CelMate® Incubator 170 L, IR Sensor, CO2 Control, ULPA, Moist Heat Decon, 230 VAC, 50/60 Hz (Without Decon Pump) CelMate® Incubator 170 L, IR Sensor, CO2 Control, ULPA, Moist Heat Decon, 115 VAC, 50/60 Hz (Without Decon Pump) CelMate® Incubator 240 L, IR Sensor, CO2 Control, ULPA, Moist Heat Decon, 230...
Open the catalog to page 10GENERAL SPECIFICATIONS TEMPERATURE Temperature Control Method Direct Heat and Air Jacket using Microcontroller PI Ambient Temperature Range Temperature Recovery Time** (after 30 seconds door opening, 98% from initial value) CO2 Recovery Time**** (after 30 seconds door opening, 98% from initial value) HUMIDITY Humidification Method PHYSICAL CONSTRUCTION Interior Volume Main Body Electrogalvanized steel with Isocide™ antimicrobial coating Interior Material Chamber Construction Number of Shelves Maximum Number of Shelves Shelves Area (W x D) Maximum Load per Shelf Stainless steel, type 304 3...
Open the catalog to page 11All ESCO catalogs and technical brochures
-
Lexicon® II
20 Pages
-
ProGene
2 Pages
-
OrbiCult Shakers
16 Pages
-
PCR Thermal Cycler
16 Pages
-
Laminar Flow Cabinets
32 Pages
-
Isotherm®
20 Pages
-
HP Series
16 Pages
-
Ascent™
12 Pages
-
Powdermax™
4 Pages
-
Ascent Series TM
24 Pages
-
CelCulture®
36 Pages
-
Streamline
4 Pages
-
Frontier®
32 Pages
-
Versati™
24 Pages
-
Airstream®
4 Pages
-
Esco Swift™ Extract
2 Pages