EWDB
1 /3Pages

EWDB

EWDB
1 /3Pages

Catalog excerpts

EWDB-1

Input Power Main Circuit Input Power Control Circuit From 24Vdc to 60Vdc - All data referred to 48Vdc +/-10% From 24Vdc to 60Vdc - All data referred to 48Vdc +/-10% From 24Vdc to 60Vdc - All data referred to 48Vdc +/-10% Output Current Control Method Analogue Input Digital Input Digital Output Status Led PWM Sinusoidal wave drive 4 x +24 Vdc (Drive Enable -Limit Switch 1,2- Homing) For status and alarms warning RS-485 (for configuration) -CANopen - EtherCAT -ProfinetIO 10A PWM Sinusoidal wave drive 4 x +24 Vdc (Drive Enable -Limit Switch 1,2- Homing) For status and alarms warning RS-485 (for configuration) -CANopen - EtherCAT -ProfinetIO 10A PWM Sinusoidal wave drive 4 x +24 Vdc (Drive Enable -Limit Switch 1,2- Homing) For status and alarms warning RS-485 (for configuration) -CANopen - EtherCAT -ProfinetIO Integrated; immediate stop or in ramp mode (optional) l2T, thermal Integrated; immediate stop or in ramp mode (optional) With Drivewatcher Software With Drivewatcher Software With Drivewatcher Software Power Loss 7,2W @ stand-by - 24,3W @ I 7,2W @ stand-by - 24,3W @ I 7,2W @ stand-by - 24,3W @ I nominal nominal nominal Integrated; immediate stop or in ramp mode (optional)

 Open the catalog to page 1
EWDB-2

EWDB Voltage 8 V/krpm Flange Interax 63 mm x Centering Connection Connectors Ml 7 for power Type and M12 for signal / fieldbus Altitude Lower than 1000m Humidity 5 to 85%RH or less both not use continuously at resonance frequency 2014/35/UE - Direttiva Bassa Tensione / Directive Basse Tension / Niederspannungsrichtlinie / Directiva de Baja Tension: Connectors Ml 7 for power and M12 for signal / fieldbus Connectors Ml7 for power and M12 for signal / fieldbus 5 to 85%RH or less both Operating and Storage 9,8m/s2 or less, 10 - 60Hz (Do not use continuously at resonance frequency 5 to 85%RH or less...

 Open the catalog to page 2
EWDB-3

General requirements. Rating General requirements. Rating General requirements. Rating specifications specifications specifications Safety requirements. Safety requirements. Safety requirements. Electrical, thermal and energy Electrical, thermal and energy Electrical, thermal and energy

 Open the catalog to page 3

All ESA elettronica catalogs and technical brochures

  1. HIDRA SWITCH

    2  Pages

  2. EWDU

    2  Pages

  3. IPC LUMIA

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.