Data sheet – MSP-FR-1

Solarsystems by Schweizer Data sheet – MSP-FR PV- Mounting system flat roof east-west PV- Mounting system green roof (e-w) Ernst Schweizer AG Bahnhofplatz 11 8908 Hedingen, Switzerland Datasheet – MSP-FR-EW subject to change without notice © Ernst Schweizer AG 09/2023 page 1/

 Open the catalog to page 1
Data sheet – MSP-FR-2

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west 8 6 Protective layer Base profile Support high Connecting rail Centre clamp MSP-FR-HC MSP-PR-HCB Additional clamp high MSP-FR-LC MSP-FR-LCB MSP-FR-S MSP-FR-TS Screw M6 x 16 resp. Screw 6,3 x 22 (Lightning current capable) Grounding screw MSP-FR-GD 6 x 60 Ernst Schweizer AG Bahnhofplatz 11 8908 Hedingen, Switzerland Data sheet – MSP-FR-EW subject to change without notice © Ernst Schweizer AG 09/2023 page 2/

 Open the catalog to page 2
Data sheet – MSP-FR-3

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west 1 Requirements for the roof Inclination Sealing material TPO/FPO, PVC, EVA, ASA, PVC-P, ECB, PIB, concrete, bitumen Friction coefficient Relevant for the design, minimum requirement depending on wind load and field geometry Insulation material EPS/XPS, mineral wool, PUR, PIR, foam glass, ... Resistance to continuous pressure ≥ approx. 10 kN/m² (depending on boundary conditions) System properties Max. Block size 3 gables x 1 row / 1 gable x 3 rows System height Ground clearance Inclination angle of the module 8° – 10°...

 Open the catalog to page 3
Data sheet – MSP-FR-4

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west Grid dimensions, scale setting Connecting rail short Tilt angle nominal 10° Inclination angle scale Support high Inclination angle scale Support low Ernst Schweizer AG Bahnhofplatz 11 8908 Hedingen, Switzerland Data sheet – MSP-FR-EW subject to change without notice © Ernst S

 Open the catalog to page 4
Data sheet – MSP-FR-5

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west Tilt angle nominal 8° Ernst Schweizer AG Bahnhofplatz 11 8908 Hedingen, Switzerland Data sheet – MSP-FR-EW subject to change

 Open the catalog to page 5
Data sheet – MSP-FR-6

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west 2.2 System geometry, dimensions in north-south direction Dimension base profiles Nominal length base profile Surface area Ernst Schweizer AG Bahnhofplatz 11 8908 Hedingen, Switzerland Data sheet – MSP-FR-EW subject to change without notice © Ernst Schweizer AG 09/2023 p

 Open the catalog to page 6
Data sheet – MSP-FR-7

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west Grid dimensions, scale setting Connecting rail long Scale support left Scale support right Ernst Schweizer AG Bahnhofplatz 11 8908 Hedingen, Switzerland Data sheet – MSP-FR-EW subject to change without notice © Ernst Schweizer AG 09/2023 page 7/

 Open the catalog to page 7
Data sheet – MSP-FR-8

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west Scale support left Scale support right Ernst Schweizer AG Bahnhofplatz 11 8908 Hedingen, Switzerland Data sheet – MSP-FR-EW subject to change without notice © Ernst Schweizer AG 09/2023 page 8/

 Open the catalog to page 8
Data sheet – MSP-FR-9

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west Scale support left Scale support right Ernst Schweizer AG Bahnhofplatz 11 8908 Hedingen, Switzerland Data sheet – MSP-FR-EW subject to change without notice © Ernst Schweizer AG 09/2023 page 9/

 Open the catalog to page 9
Data sheet – MSP-FR-10

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west Scale support left Scale support right Ernst Schweizer AG Bahnhofplatz 11 8908 Hedingen, Switzerland Data sheet – MSP-FR-EW subject to change without notice © Ernst Schweizer AG 09/2023 page 10/

 Open the catalog to page 10
Data sheet – MSP-FR-11

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west 3 Components Description Support high Connecting rail crosswise Connecting rail longitudinal Protective layer (inserted) MSP-FR-EW-C 300-360 MSP-FR-EW-C 470-530 MSP-FR-EW-C 950-1010 MSP-FR-EW-C 1011-1075 MSP-FR-EW-C 1076-1140 MSP-FR-EW-C 1141-1205 MSP-FR-EW-C 1206-1270 MSP-FR-EW-C 1271-1335 MSP-FR-EW-C 1555-1619 MSP-FR-EW-C 1620-1684 MSP-FR-EW-C 1685-1749 MSP-FR-EW-C 1750-1814 MSP-FR-EW-C 1815-1879 MSP-FR-EW-C 1880-1944 MSP-FR-EW-C 1945-2009 MSP-FR-EW-C 2010-2074 MSP-FR-EW-C 2075-2139 MSP-FR-EW-C 2140-2204 MSP-FR-EW-C...

 Open the catalog to page 11
Data sheet – MSP-FR-12

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west MSP-FR-TS Schraube 6,3 x 22 (Lightning current capable) Earthing screw Carbon steel / ZnNi-coated >10 μm Carbon steel / ZnNi-coated >10 μm Carbon steel / ZnNi-coated >10 μm Wind deflector MSP-FR-EW-WD 1620-1684 MSP-FR-EW-WD 1685-1749 MSP-FR-EW-WD 1750-1814 MSP-FR-S-WD 1620-1684 MSPFR-S-WD 1685-1749 MSP-FR-SWD 1750-1814 Sheet steel SVZ/ZM coated Sheet steel ZM-coated Ballast carrier Ballast carrier clamp Ballast carrier start plate Gravel tray MSP-FR-EW-S MSP-FR-BT 1620-1749 N MSP-FR-BT 1750-1879 N MSP-FR-BT 1880-2009...

 Open the catalog to page 12
Data sheet – MSP-FR-13

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west Description Centre clamp Additional clamp high MSP-PR-MC 28-45m MSP-PR-MCG 28-45mm MSP-PR-MCB 28-45mm MSP-PR-MCBG 28-45mm Safety washer PE-HD oder PVC Safety washer PE-HD oder PVC Rated resistances of the components and connections In order to verify the resistance values of flat roof systems of type MSP-FR, the values of each component must be considered individually:          Load-bearing capacity of the roof Compressive strength of the thermal insulation Static friction between the roof waterproofing and...

 Open the catalog to page 13
Data sheet – MSP-FR-14

Solarsystems by Schweizer Data sheet – PV- Mounting system flat roof east-west The resistance values only apply if the complete MSP-FR-EW system from Schweizer is used and the installation is carried out in accordance with the installation instructions MSP-FR-EW PV mounting system flat roof east-west. 4.1 Resistances of the support low MSP-FR-EW-SL8/SL10 Pressure resistance Pull resistance Shear resistance Shear resistance 4.2 Resistances of the support high MSP-FR-EW-SH Pressure resistance Pull resistance Shear resistance SRd Fig. 2: Vectors of the resistances of the support high MSP-FR-EW-SH...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.