T-PRO 4000

T-PRO 4000

T-PRO 4000

Product catalog summary
Product Overview
The T-PRO 4000 Transformer Protection Relay provides comprehensive protection and monitoring for multi-winding transformers. It includes advanced communication protocols, fault logging, and monitoring features, making it suitable for high-speed protection and control of transformers with HV and LV windings in ring or breaker-and-a-half configurations.
Key Features
  • Intuitive setting and analysis software.
  • IEC 61850 communication via optical/copper ports.
  • Internal magnitude and phase shift compensation.
  • Harmonic restraint algorithm for improved security.
  • THD alarm function for waveform distortion alerts.
  • Asset management for maximizing transformer capacity.
  • Through Fault Monitoring for preventive maintenance.
  • Ambient Temperature Adaption for overcurrent protection.
  • High-quality fault recording and event logging.
  • Eight setting groups for various operating conditions.
Ease of Use
The relay is designed for easy installation, maintenance, and operation, featuring user-friendly Windows-based software for relay setting and record analysis, flexible programmable logic, and multiple setting groups with unique logic control statements.
Application
The T-PRO 4000 is applicable for transformers in substations with ring bus or breaker-and-a-half configurations, supporting substation automation with IEC 61850 protocol for data transfer and remote monitoring.
Protection & Control
The relay includes a wide range of protection functions such as differential protection, overcurrent protection, and thermal overload protection, along with enhanced user-configurable logic and asset management capabilities.
Flexible Communications
The relay supports multiple communication protocols including IEC 61850, DNP3, and Modbus, featuring Ethernet ports with unique MAC addresses for network security, and supports precise time stamping and synchronization.
Environmental and Physical Specifications
The relay operates within a wide temperature range and is tested for various environmental conditions such as humidity, electrical fast transients, and RFI susceptibility. It is available in different chassis sizes with specific weight and dimension specifications.
Testing and Compliance
The T-PRO 4000 complies with various international standards for emissions, immunity, and environmental testing, ensuring reliable performance in diverse conditions.
Specifications
  • Signal Ports: 2.5 kV Common, 1 kV Differential for AC and DC power ports.
  • Oscillatory Signal Ports: 2.5 kV Common, 0 kV Differential.
  • Mains Frequency Voltage: 30 V continuous, 300 V for 1 second for signal and AC power ports.
  • Ripple on DC Power Supply: 10% for DC power port.
Notes
  • The T-PRO 4000 is available with 5 or 1 amp current input, affecting all current specifications.
  • TOEWS and Transformer asset monitoring require optional temperature inputs.
Contact Information
Disclaimer Specifications and product information are subject to change without notice. In case of inconsistencies, the version on the website is considered correct.
See more

Catalog excerpts

T-PRO 4000-1

Transformer Protection Relay T-PRO 4000 Product Overview The IEC 61850 station bus embedded T-PRO 4000 relay provides complete three-phase multi-winding transformer fault and overload protection, DFR-quality fault oscillography, fault logging, sequence of event logging, trend recording, transformer monitoring and overload early warning (TOEWSTM) integrated with advanced communications in a flexible, cost effective package. Apply the T-PRO 4000 system for high speed protection and complete control of multi-winding transformers with the HV and LV windings connected to ring or breaker-and-a-half arrangements. • Easy-to-use, intuitive setting and analysis software • IEC 61850 communication via optical/copper ports • Internal magnitude and phase shift compensation, eliminating requirements for external CT connections and auxiliary CTs • 2nd and 5th harmonic restraint algorithm that improves security for energization, inrush and overfluxing • THD alarm function that alerts to the degree of current waveform distortion and therefore harmonic content • Asset management to maximize use of transformer capacity (ANSI/IEEE C57.91-1995) • Through Fault Monitoring function to measure the duration, current peak RMS and accumulated I2t values for each phase during through fault (use this information for analysis and preventive maintenance planning) • Ambient Temperature Adaption (ADP) adjusts the pickup level of the time overcurrent protection (51HV) based on the ambient temperature • High quality fault recording, trending and event log • 8 setting groups to accommodate for various operating conditions • Ethernet ports with 2 unique MAC addresses accommodate network access security needs

 Open the catalog to page 1
T-PRO 4000-2

Application • Primary and back-up protection, and management of small, medium and large power transformers, and reactors. • Transformer asset monitoring using thermal overload based on hottest spot or top oil temperature, Transformer Overload Early Warning System (TOEWSTM), and Through Fault Monitoring1 • Applicable for transformers installed in substations with bus bar arrangement in a ring bus or breaker-and-a-half configuration Protection & Control • Protection functions include IEEE devices 87, 87N, 49, 67, 50/51, 50N/51N, 51ADP, 50BF (each winding), 24INV/DEF, 59N, 59, 60, 81U/O, THD, 27,...

 Open the catalog to page 2
T-PRO 4000-3

Flexible Communications • 2 rear ports, 100BASE-TX RJ-45 or 100BASE-FX 1300 nm multimode optical with ST style connector • Ethernet ports with 2 unique MAC addresses that easily accommodate network access security needs • Front panel USB and 100BASE-TX RJ-45 Ethernet port interfaces Substation Automation - Ethernet Ready • Standard IEC 61850 Station Bus on a dedicated optical/copper Ethernet port • Enhanced DNP3 SCADA communication protocol including user-selectable point lists, class support and multiple master station support • Modbus SCADA communication protocol Multi-Functional Recording...

 Open the catalog to page 3
T-PRO 4000-4

Best in Class Human-Machine Interface Large LCD display, allows for better metering display Navigation controls allow for an easy experience through settings, maintenance, service and view menus New faster processor and hardware platform Programmable target LEDs provide tripping information to expedite response to systems events Unique front panel USB and Ethernet ports provide easy and fast access to settings and set up Rear optical ports ready for IEC 61850 Protection & Control Function Diagram High Voltage (HV) 50 BF-1 Through Fault Monitor 18 Analog Inputs 20 External Inputs (4U) 9 External...

 Open the catalog to page 4
T-PRO 4000-5

Detailed SpecificationsT-PRO 4000 Transformer Protection Relay Item General Nominal Frequency Operating Time Power Supply Including relay output operation Power Consumption: 25 - 30 VA (ac) 25 - 30 W (dc) Sequence of Events Recorder Record Capacity Settings and records are stored in non-volatile memory 2 or 3 winding transformer with 5 sets of 3-phase current inputs, 1 set of 3-phase voltage inputs. 2 optional temperature inputs (4 - 20 mA dc) 24 statements per setting group 8 (16 group logic statements per setting group) 96 s/c oscillography of all analog and external input digital channels 3...

 Open the catalog to page 5
T-PRO 4000-6

T-PRO 4000 Transformer Protection Relay Item Quantity/Specs Notes Interface & Communication Front Display Front Panel Indicators Front User Interfaces Rear User Interfaces Internal Modem SCADA Interface Time Sync Self Checking/Relay Inoperative Environmental Ambient Temperature Range 240 x 128 pixels graphics LCD 16 LEDs: 11 programmable and 5 fixed USB port and 100BASE-T Ethernet port LAN Port 1: 100BASE - copper or optical 1300 nm LAN Port 2: 100BASE - copper or optical 1300 nm Two serial RS-232 ports to 115 kbd 33.6 Kbps, V.32 bis I EC 61850, DNP3 (RS-232 or Ethernet) or Modbus (RS-232) IRIG-B,...

 Open the catalog to page 6
T-PRO 4000-7

Overall T-PRO Accuracies Current Voltage Differential Element Directional Phase Angle Frequency Elements Inverse Overcurrent Timers ±2.5% of inputs from 0.1 to 1.0 x nominal current (In) ±1.0% of inputs from 1.0 to 40.0 x nominal current (In) ±1.0% of inputs from 0.01 to 2.0 x nominal voltage (Vn) ±5.0% of set value IOmin from 0.10 to 1.0 per unit (pu) ±2.5% or > 2.0 of set value from 0.01 to 360.0 ±0.001 Hz (fixed level) ±0.05 Hz (df/dt) ±2.5% or 1 cycle of selected curve Detailed Environmental Tests Test FCC Part 15 IEC/EN 60255-25 IEC/EN 61000-3-2 Description Type Test RF emissions Conducted...

 Open the catalog to page 7
T-PRO 4000-8

Detailed Environmental Tests Test Description Type Test IEC/EN 60255-22-7 Power frequency IEC/EN 61000-4-8 Magnetic field IEC/EN 61000-4-11 Voltage dips & interrupts Test Points Binary input ports: Class A Enclosure ports ac power port Voltage dips & interrupts Damped oscillatory IEC/EN 61000-4-16 Mains frequency voltage IEC/EN 61000-4-17 Ripple on dc power supply dc power port dc power port Communication ports Signal ports ac power port dc power port Signal ports ac power port dc power port Signal ports ac power port dc power port Test Level Differential = 150 Vrms Common =...

 Open the catalog to page 8

All ERLPhase catalogs and technical brochures

  1. ERMLG

    4  Pages

  2. L-PRO

    8  Pages

  3. S-PRO 4000

    9  Pages

  4. L-PRO 4000

    9  Pages

  5. F-PRO

    8  Pages

  6. B-PRO 4000

    8  Pages

  7. TESLA LITE

    5  Pages

  8. TESLA 4000

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.