Product Overview
The B-PRO Multi Busbar (MBB) Protection System is engineered for efficient and secure protection of busbar configurations. It features a scalable architecture for flexible hardware combinations based on zones and current inputs. The system supports low impedance bus differential protection, check zone protection, CT open detection, and circuit breaker failure protection, along with control, automation, metering, monitoring, and advanced communication capabilities.
Key Features
  • Dynamic Bus Replica for each bay, eliminating external auxiliary relays.
  • Integrated Breaker Fail Protection and advanced fault recording.
  • IEC 61850 communications via optical/copper ports and two Ethernet ports with unique MAC addresses.
  • Enhanced user-configurable logic with ProLogicTM, offering 24 control logic statements per relay.
  • Multiple zones of protection with integrated Check Zone and CT Supervision.
Application
The B-PRO MBB system is suitable for differential protection of busbars, T-sections, and meshed corners, adaptable to various bus and switchgear configurations.
Architecture
The system's architecture supports scalability and flexibility in low impedance busbar protection applications, with each B-PRO relay providing six sets of 3-phase CT inputs for differential protection.
Protection & Control
  • Windows®-based relay setting and record analysis software.
  • Relay Control Panel for online monitoring and event handling.
  • Substation automation with IEC61850 station bus protocol for data transfer.
  • Front Panel Indicators with user-configurable LEDs for system event response.
Installation and Maintenance
  • Flexible communications with multiple ports and protocols, including IEC 61850, DNP3, and Modbus.
  • Exceptional fault recording capabilities with 96 samples/cycle and dynamic swing recording.
  • Multi-functional recording and event logging with up to 150 seconds of transient record.
Specifications
  • Nominal Frequency: 50 or 60 Hz.
  • Operating Time: Less than 15 ms for IEEE Device 87B.
  • Power Supply: 25 – 30 VA (ac) or 25 – 30 W (dc).
  • Environmental: Operates in temperatures from -40°C to 85°C.
Specifications
The document details specifications for electrical components, including analog and external inputs, and output contacts tested at 2.0 kV, 50/60 Hz for 1 minute, adhering to IEC 60255-5 and ANSI/IEEE C37.90 standards. It includes accuracy of B-PRO measurements and burden on AC voltage and current inputs.
Procedures
Various tests ensure compliance with international standards, including Electrical Fast Transient, Oscillatory Transient, RFI Susceptibility, and Vibration, Shock, and Bump tests, meeting standards like IEEE C37.90.1, IEC 60255-22-4, and IEC 61000-4-4.
Standards
The document references standards such as IEC/EN 61000 series and IEEE C37.90 series for emissions, power line harmonics, ESD, radiated RFI, surge, and voltage dips and interruptions, ensuring product reliability and safety.
Environmental Tests
Environmental tests cover RF emissions, conducted emissions, power line harmonics, ESD, radiated RFI, burst, surge, induced RFI, power frequency, magnetic field, voltage dips, and interruptions, ensuring compliance with relevant standards.
Revisions and Contact Information
Specifications and product information are subject to change without notice, with the latest version available on the company's website. Contact information for ERLPhase Power Technologies is provided for further inquiries.
See more

Catalog excerpts

Multi Busbar Protection Relay-1

Multi Busbar Protection Relay Product Overview The B-PRO Multi Busbar (MBB) Protection System provides fast, reliable and secure protection for any busbar configuration with built in check zone feature. Its scalable architecture allows flexibility to use the optimum hardware combinations based on the actual number of zones and number of current inputs (bays) in the bus system. The IEC61850 station bus embedded B-PRO MBB system provides low impedance bus differential protection, independent check zone protection, CT open detection & blocking, advanced CT saturation detection, circuit breaker failure protection, end fault (blind zone) protection and backup over current & earth fault protection from distribution to EHV substations. It also provides control, automation, metering, monitoring, fault oscillography, event logging, fault logging and dynamic swing recording, with advanced communications in a flexible cost effective package. • Easy-to-use, intuitive setting and analysis software • Configure up to 4 B-PRO relays, each with 6 x 3 Phase CT Inputs, to protect one integrated Multi Bus System • Dynamic Bus Replica • Isolator and CB status monitoring and alarming for mismatch positions • Integrated Breaker Fail Protection with external singlephase initiation, End Zone and Over Current & Earth fault Protection for each input current (bay) • High quality fault recording and event log • Delta phase and Rate of Change of Differential Algorithms for improved selectivity and security • IEC 61850 communications via optical/copper ports • Two Ethernet ports with unique MAC addresses accommodate network access security needs

 Open the catalog to page 1
Multi Busbar Protection Relay-2

Application B-PRO MBB system can be effectively used for fast, reliable and secure differential protection of busbars, T-sections and meshed corners. It provides protection for multiple zones and finds application in a variety of bus and switchgear configurations. It can be used for differential protection of single or double bus with or without transfer bus, single and double breaker, breaker-and-a-half configurations and busbars with sectionalizing breakers or isolators. As a typical case, protection for 22 bays plus one bus transfer breaker and one bus coupler breaker can be provided using...

 Open the catalog to page 2
Multi Busbar Protection Relay-3

Features & Benefits Ease of Use • Easy-to-use, install and maintain • User-friendly, Windows®-based relay setting and record analysis software • Relay Control Panel - for on-line monitoring, DR fault log & Event handling • Flexible programmable logic for building customized schemes with ProLogic™ statements - 24 control logic statements per relay Ease of Installation and Maintenance • Substation automation - includes IEC61850 station bus protocol to display and transfer operational data via local-area network (LAN) for local HMI and wide-area network (WAN) for remote monitoring SCADA • IEC 61850...

 Open the catalog to page 3
Multi Busbar Protection Relay-4

Multi-Functional Recording and Event Logging • Exceptional fault recording capabilities with 96 samples/cycle and dynamic swing recording at 1 sample/cycle • Up to 150 seconds of transient record, or up to 150 mins of swing records, or combination of transient, swing and optionally event records • Metering functions for each current input • Sequence of Event Recorder with 1 ms resolution • Compressed event record capabilities – a compressed sequence of event fileiscreatedevery250events RecordGraphTM and RecordBase ViewTM • Display multiple channels simultaneously and combine records • Display...

 Open the catalog to page 4
Multi Busbar Protection Relay-5

Typical Application Diagrams Figure 1. Single Bus Application

 Open the catalog to page 5
Multi Busbar Protection Relay-6

Figure 2. Single Bus, Multi Zone Application

 Open the catalog to page 6
Multi Busbar Protection Relay-7

Figure 3. Multi Zone Application Topology Inputs & Outputs Inputs & Outputs Inputs & Outputs

 Open the catalog to page 7
Multi Busbar Protection Relay-8

Figure 4. Double Bus Application Topology

 Open the catalog to page 8
Multi Busbar Protection Relay-9

Best in Class Human-Machine Interface Large LCD display, allows for better metering display Navigation controls allow for an easy experience through maintenance, service and view menus New faster processor and hardware platform Programmable target LEDs provide tripping information to expedite response to system events Unique front panel USB and Ethernet ports provide easy and fast access to settings and set up Rear optical ports ready for IEC 61850 Protection & Control Function Diagram Transfer Bus Bus A Bus B PT X These protection functions are available for each current input. B-PRO Unit

 Open the catalog to page 9
Multi Busbar Protection Relay-10

Item General Nominal Frequency Operating Time Sampling Rate Power Supply Protection Functions IEEE Device 87B, 60 CTS, End Fault, 50BF, 50LS, 50/51/67, 50N/51N/67, 46-50/67, 46-51/67, 27,59, 60VTS, 81O, 81U Multiple Zones of Protection ProLogic Recording Record Capacity Quantity/Specs 50 or 60 Hz 87B: less than 15 ms 96 samples/cycle for recording Range: 43 - 275 Vdc, 90 - 265 Vac 6 x 3-phase current inputs (18 current channels) per B-PRO relay 1 x 3-phase voltage inputs (3 voltage channels) per B-PRO relay Up to 3 bus differential zones and a check zone 24 statements per B-PRO relay Including...

 Open the catalog to page 10
Multi Busbar Protection Relay-11

Item Quantity/Specs Output (contacts) for each 14 programmable outputs and 1 relay inoperative output B-PRO relay Virtual Inputs 30 Virtual Inputs B-PRO 4000 I/O External Inputs Up to 128 extended Inputs and 16 Outputs per I/O Unit. and Outputs Notes Make: 30 A as per IEEE C37.90 Carry: 8 A Break: 0.9 A at 125 Vdc 0.35 A at 250 Vdc Interface & Communication on each B-PRO 4000 Relay Front Display 240 x 128 pixels graphics LCD Front Panel Indicators 16 LEDs: 11 programmable and 5 fixed Front Panel Interfaces Rear User Interfaces SCADA Interface USB port and 100BASE-TX Ethernet LAN...

 Open the catalog to page 11
Multi Busbar Protection Relay-12

Item Environmental Ambient Temperature Range Humidity Insulation Test (Hi-Pot) Electrical Fast Transient Oscillatory Transient RFI Susceptibility Vibration, Shock and Bump Conducted RF Immunity Voltage Interruptions Quantity/Specs Notes -40°C to 85°C for 16 hours -40°C to 70°C continuous Up to 95% without condensation Power supply, analog inputs, external inputs, output contacts at 2.0 kV, 50/60 Hz, 1 minute Tested to level 4 - 4.0 kV 2.5/5 kHz on power and I/O lines Test level = 2.5 kV 10 V/m modulated, 35 V/m unmodulated 3 g, 5 g and 15 g 200 ms interrupt Overall B-PRO Accuracies: Current...

 Open the catalog to page 12

All ERLPhase catalogs and technical brochures

  1. ERMLG

    4  Pages

  2. T-PRO 4000

    8  Pages

  3. L-PRO

    8  Pages

  4. S-PRO 4000

    9  Pages

  5. L-PRO 4000

    9  Pages

  6. F-PRO

    8  Pages

  7. B-PRO 4000

    8  Pages

  8. TESLA LITE

    5  Pages

  9. TESLA 4000

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.