L-PRO

L-PRO

L-PRO

Product catalog summary
Product Overview
The L-PRO is an advanced transmission line protection relay designed for comprehensive protection across all voltage levels, including Extra High Voltage lines. It integrates control, automation, metering, monitoring, and communication features, suitable for high-speed protection in multi-breaker applications and various bus configurations.
Key Features
  • Intuitive setting and analysis software.
  • IEC 61850 communication with optional PRP via optical/copper ports.
  • Selectable single and three-pole trip and reclose options.
  • High-speed five-zone user-defined Mho or Quad characteristics for phase and ground distance protection.
  • High-quality fault recording and event logging.
  • Suitable for overhead lines, underground cables, and series compensated lines.
Protection & Control
  • Wide range of protection functions including 21P, 21N, 27, 50BF, and more.
  • High-speed phase and ground distance functions with user-defined Mho shapes or Quadrilateral protection.
  • Operating time typically less than 25 milliseconds.
  • Enhanced user-configurable logic with ProLogicTM and Group Logic Control Statements.
Ease of Use
  • User-friendly Windows-based relay setting and record analysis software.
  • Flexible programmable logic for customized schemes.
Cost Efficiency
  • Reduced substation automation costs with IEC 61850 protocol.
  • Convenient product setting with a graphical user interface.
Communications
  • Ethernet ports with optional PRP compliance.
  • Support for multiple SCADA communication protocols including IEC 61850, DNP3, and Modbus.
Recording and Event Logging
  • Exceptional fault recording capabilities with user-selectable pre-fault and total record lengths.
  • Sequence of event recorder with high resolution.
Human-Machine Interface
  • Large LCD display for better metering display.
  • Navigation controls for easy access to settings and maintenance.
Specifications
  • Nominal frequency: 50 or 60 Hz.
  • Power supply range: 20 - 60 Vdc / 20 – 60 Vac and 80 - 300 Vdc / 80 – 250 Vac.
  • Memory: Non-volatile with FIFO method for records.
  • Analog sampling rate: 128 samples/cycle for recording.
Environmental Tests
  • Complies with IEC 60255-26:2013 standards for various emissions and interference tests.
Specifications
1. Voltage Dips & Interrupts: The AC power port must withstand voltage dips of 30% for 1 period, 60% for 50 periods, and 100% for 5 and 50 periods. The DC power port must handle 30% for 0.1 seconds, 60% for 0.1 seconds, and 100% for 0.05 seconds.
2. Ambient Temperature: The equipment should operate between -40°C to 85°C for 16 hours and continuously from -40°C to 70°C. LCD contrast may be impaired below -20°C and above 70°C.
3. Humidity: Up to 95% humidity without condensation.
4. Vibration: Sinusoidal vibration testing from 10 Hz to 150 Hz, with 1.0 octave/min and 40 sweeps.
5. Shock & Bump: Shock and bump testing at 5 g and 15 g.
Procedures
Testing procedures for voltage dips, temperature, humidity, vibration, and shock to ensure compliance with international standards.
Recommendations
Continuous improvement and development are emphasized, with a note that equipment may vary slightly from descriptions.
Contact Information
Easun Reyrolle Ltd. and ERLPhase Power Technologies Ltd. provide contact details for technical support and general inquiries.
See more

Catalog excerpts

L-PRO-1

Transmission Line Protection Relay Product Overview The L-PRO provides easy to use, state of the art comprehensive distance and backup directional line protection for all voltages including Extra High Voltage transmission lines using communication based schemes. It provides control, automation, metering, monitoring, DFR-quality fault oscillography, dynamic swing recording, fault logging, sequence of event logging with advanced communication features in a flexible, cost effective package. L-PRO can be for High Speed Protection and Complete Control in Multi breaker Applications to all bus types such as ring or breaker-and-ahalf arrangements. The L-PRO takes into effect the influence of adjacent parallel lines through mutual coupling settings. • Easy-to-use, intuitive setting and analysis software • IEC 61850 communication along with Optional PRP (IEC 62439-3) via optical/copper ports • Selectable Single and 3 Pole Trip and reclose • High Speed Five Zone User defined Mho or Quad Characteristics for Phase and Ground Distance Protection • High quality fault recording, swing and event log • Single and Multi Breaker Applications (i.e., Ring Bus and Breaker and Half Configurations including Individual Breaker Failure) • 4 Shot recloser with dead line / dead bus control and Sync. Check • 8 setting groups to accommodate for various o

 Open the catalog to page 1
L-PRO-2

Application • Suitable for Overhead lines and underground cables (using pilot protection schemes) • Backup protection for generators, transformers and reactors • Ideal for multi-circuit line applications (to monitor mutual coupling via additional CT inputs) • Suitable for Series compensated Lines Protection&Control • Protection functions - 21P, 21N, 27, 50BF, 50LS, 50/51/67, 50N/51N/67, 50G/51G/67, 46-50/46-51/67, 59, 59N, 60, 60CTS, 68, 79, 81/81R, 25/27/59 (Check Sync), Dead Line Pickup (SOTF), Weak In feed, Mutual Compensation and Series Compensation. • High-speed 5 zones of phase and ground...

 Open the catalog to page 2
L-PRO-3

Flexible Communications • 100BASE-TX RJ-45 or 100BASE-FX 1300nm multimode Optical with ST style connector • Ethernet ports with PRP compliant (Optional) • Front panel USB interface Substation Automation - Ethernet Ready • Standard IEC 61850 Station Bus & Optional PRP (IEC 62439-3) on a dedicated Optical / Copper Ethernet port • Enhanced DNP3 SCADA communication protocol including user Selectable point lists, class support and multiple master stations Support • Modbus SCADA communication protocol • 30 Virtual Inputs for local and remote control Multi-Functional Recording and Event Logging • Exceptional...

 Open the catalog to page 3
L-PRO-4

Best in Class Human-Machine Interface New faster processor and hardware platform Large LCD display, allows for better metering display Rear optical ports ready for IEC 61850 along with PRP (Optional) Programmable target LEDs provide tripping information to expedite response to systems events Navigation controls allow for an easy experience through settings, maintenance, service and view menus Front panel USB port provides easy and fast access to settings and set up Protection & Control Function Diagram

 Open the catalog to page 4
L-PRO-5

Detailed Specifications L-PRO Transmission Line Protection Relay Item General Nominal Frequency Operating Time Power Supply Memory Protection Functions Quantity/Specs 50 or 60 Hz < 25 msec typical Range: 20 - 60 Vdc / 20 - 60 Vac 80 - 300 Vdc / 80 - 250 Vac Settings and records are stored in non-volatile memory Notes Including relay output operation Power Consumption: 20 - 30 W / VA Records are stored in FIFO method Sequence of Events Recorder Record Capacity 2x 3-phase voltage inputs for synchronizing during reclosing 2 x 3-phase current inputs for protection 2X 1-phase current for Measured...

 Open the catalog to page 5
L-PRO-6

Front Display 128 X 64 pixels graphics LCD Front Panel Indicators 22 LEDs (17 programmable and 5 fixed) Front User Interfaces USB port Rear User Interfaces LAN Port 1: 100 BASE - copper or optical 1300 nm LAN Port 2: 100 BASE - copper or optical 1300 nm One serial RS-485 ports SCADA Interface IEC 61850, PRP (IEC 62439-3) DNP3 (RS-485 or Ethernet) or Modbus (RS-485) Time Sync IRIG-B,BNCconnector B003, B004, B123 and B124 Time Codes SNTP Self Checking/Relay Inoperative 1 contact Time Synchronization and Accuracy Target (17), Unit Functional, Time Sync, Test Mode, Service Required,...

 Open the catalog to page 6
L-PRO-7

Detailed Environmental TestsStandard Description of the Test Test Points Test Level IEC 60255-26:2013 Cl.No.7.1.2 IEC 60255-26:2013 Cl.No.7.1.3 IEC 60255-26:2013 Cl.No.7.2.3 IEC 60255-26:2013 Cl.No.7.2.4 IEC 60255-26:2013 Cl.No.7.2.5 Radiated Emissions Conducted Emissions Electrostatic Discharge Radiated interference Electrical Fast Transient Slow Damped Oscillatory / High Frequency Disturbance / 1 MHz Burst Disturbance Conducted Interference Enclosure ports Ac/Dc power ports Enclosure Air Enclosure contact Enclosure ports Ac/Dc power ports AC voltage & current ports External I/P & O/P...

 Open the catalog to page 7
L-PRO-8

INTENTIONALLY LEFT BLANK WORKS: Easun Reyrolle Ltd., #98, Sipcot Industrial Complex, Hosur 635 126, India Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 E-Mail: [email protected] The policy of ERL is continuous improvement and development. The from that described and illustrated in this publication (E00006R04). ERLPhase Power Technologies Ltd., 74 Scurfield Blvd, Winnipeg, MB, R3Y 1G4 Canada Tel: +1 204-477-0591 Fax: +1 204-478-1697 E-Mail: [email protected] therefore reserves the right to supply equipment which may differ slightly Technical Support: [email protected] / [email protected]...

 Open the catalog to page 8

All ERLPhase catalogs and technical brochures

  1. ERMLG

    4  Pages

  2. T-PRO 4000

    8  Pages

  3. S-PRO 4000

    9  Pages

  4. L-PRO 4000

    9  Pages

  5. F-PRO

    8  Pages

  6. B-PRO 4000

    8  Pages

  7. TESLA LITE

    5  Pages

  8. TESLA 4000

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.