Overview: This document provides technical specifications and characteristics of two digital meters, UT502 and UT595, used by electricians for various measurements including insulation resistance, load current, and more.
Insulation Resistance:
  • UT502: Measures from 3 MΩ to 2000 MΩ at 500 V, and up to 20 GΩ at 2500 V.
  • UT595: Measures from 5 MΩ to 4000 MΩ at 500 V, and up to 1000 MΩ at 1000 V.
Load Current: Both models support a load current of 1 mA across different voltage settings (250/500 V, 500/1000 V, 1000/2500 V).
Test Voltages: Range from 500 V to 2500 V with a short circuit current of less than 2 mA.
Resistance and Impedance:
  • Low resistance continuity range: 0 Ω to 199 Ω with a testing current of >200 mA for 0~2 Ω.
  • Line and loop impedance range: 0.01 Ω to 2000 Ω with operational voltage from 195 V to 440 V (45~65 Hz) and testing current of 20 A.
  • Loop impedance without tripping: 1 Ω to 2000 Ω with a testing current of 15 mA.
RCD Testing: Operational voltage from 195 V to 253 V (45~65 Hz) with various testing currents (10 mA to 500 mA) and trip times ranging from 0 to 2000 ms depending on the mode.
Phase Sequence Test: Operational voltage from 100 V to 440 V (45~65 Hz) with indication for positive and reverse changes.
Voltage Measurement:
  • DC Voltage: 0 to 1000 V with a resolution of 1 V.
  • AC Voltage: 0 to 750 V with a resolution of 1 V.
Features: Both models offer auto/manual range selection, low battery indication, and alarms.
General Characteristics:
  • Power: UT502 uses 6x LR6 batteries, UT595 uses 8x LR6 batteries.
  • LCD Size: UT502 is 71x34 mm, UT595 is 125x37 mm.
  • Weight: UT502 is 500 g, UT595 is 1000 g.
  • Product Size: UT502 is 150x100x71 mm, UT595 is 210x175x90 mm.
  • Standard Accessories: Include test lead, batteries, manual, alligator clip, and case.
See more

Catalog excerpts

Digital Meters - UT502/UT595-1

Electricians tools Type / Characteristics Short circuit current <2 mA <2 mA Low resistance continuity Line impedance Loop impedance Loop impedance without tripping Phase sequence test RCD measurement ramp slope DC voltage 0~1000 V range: 0 n ~199 n testing current: 0~2 n: >200 mA range: 0.01 n~2000 n operational voltage: 195 V~440 V (45~65 Hz) testing current: 20 A PFC range: 0 kA~26 kA range: 0.01 n ~2000 n operational voltage: 195 V~253 V (45~65 Hz) testing current: 20 A PFC range: 0 kA~26 kA range: 1 n ~2000 n operational voltage: 195 V~253 V (45~65 Hz) testing current: 15 mA PFC range: 0 kA~26 kA operational voltage: 195 V~253 V (45~65 Hz) testing current: 10 mA, 30mA, 100 mA, 300 mA, 500 mA trip time: x *lAn range 0~2000 ms x 1 *lAn range 0~300 ms x 1 *lAn range 0~500 ms (selective mode) x 2 *lAn range 0~300 ms x 2 *lAn range 0~500 ms (selective mode) x 5 *lAn range 0~40 ms operational voltage: 100 V~440 V (45~65 Hz) indication: L1—>L2—>L3 - positive change, L1—>L3—>L2 - to reverse testing current: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA range: 0 V~440 V frequency: 45~65 Hz resolution: 1 V range: 0 V~440 V frequency: 45~65 Hz resolution: 1 V Auto/manual range Alarm Low battery indication General characteristics Standard accessories test lead, batteries, manual, alligator clip, case test lead, batteries, manual, alligator clip