R1866
3Pages

{{requestButtons}}

Catalog excerpts

R1866 - 1

• Thin Layers of bare electrolytic copper formed into a stack • Full range from 19.5 mm2 up to 1200 mm2 and 125 A to 2800 A • Insulated by high-resistance, self-extinguishing PVC with Less than 20% contact with conductor for high flexibility • Easily bent, folded, and twisted, improving assembly flexibility, shortening connections, and decreasing footprint • Dramatically smaller and more flexible than comparable cable based on ampacity • Better power density than cable with lower skin effect ratio • Connections made by punching and bolting directly through the copper laminates, clamping onto the end of the nVent ERIFLEX Flexibar, or welding using nVent ERICO Cadweld • No lugs needed, reducing installation time and improving resistance to vibration • Weight savings and material savings compared to wire alternatives • Reduces total installation cost • Traceability codes and designation part numbers printed on insulation • 100% production dielectric tested • UL 758 Appliance Wiring Material requirements for Cold Bend testing at -40°C and -50°C (-40°F and -58°F) • EAC compliant • RoHS compliant Length: 2 000 mm Material: Copper, Polyvinylchloride Dielectric Strength: 20 kV/mm Flammability Rating: UL® 94V-0 Insulation Elongation: 370 % Insulation Thickness: 2 mm Nominal Voltage, UL/CSA/IEC: 1 000 VAC, 1 500 VDC Working Temperature: -50 to 105 °C Forming Temperature: 0 - 55 °C Certification Details: UL® 67, UL® 758 Complies With: IEC® 60439.1, IEC® 61439.1, IEC® 61439.1 Class II, IEC® 60695-2-1 1 (Glow Wire Test 960 °C)

Open the catalog to page 1
R1866 - 2

ADMISSIBLE CURRENTS: This table indicates the temperature rise produced by chosen current in the given section. This calculation does not take into account the heat dissipation from the switch gear. AT = Temperature of conductors - Internal temperature of panel. Refer to technical documentation for additional ampacity ratings.

Open the catalog to page 2
R1866 - 3

ABS is a registered certification mark of American Bureau of Shipping. IEC is a registered trademark of the International Electrotechnical Commission. UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC. WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent 's instructions and warnings may cause...

Open the catalog to page 3

All ERICO catalogs and technical brochures

  1. R2411

    3 Pages

  2. R2119

    2 Pages

  3. R1913

    1 Pages

  4. R1914

    1 Pages

  5. R1930

    2 Pages

  6. R1966

    2 Pages

  7. R3500

    3 Pages

  8. R3548

    3 Pages

  9. R852

    1 Pages

  10. R1985

    1 Pages

  11. R2006

    1 Pages

Archived catalogs