The solenoid valve type 30029 is a 3/2 normally closed (NC) valve with direct operation. It is compatible with air, water, gas, and light oil. The valve operates within a pressure range of 0 to 12 bar and can handle media temperatures up to 100°C. The ambient temperature range is -10°C to +50°C, and the maximum media viscosity is 40 centistokes. The valve can be mounted in any position and weighs 280 grams, including the coil. The opening or closing time is a maximum of 20 milliseconds.
Pressure Specifications
The valve's pressure specifications vary based on the diameter of the passage and seat, with different configurations for air/gas and water/oil. The sealing materials available are NBR, EPDM, and FKM, with maximum fluid temperatures of 60°C or 100°C depending on the material. Specific ordering codes are provided for each configuration.
Electrical Data
The valve operates on AC voltages of 12-230V (50 or 60 Hz) with an inrush power of 26 VA and holding power of 14 VA. For DC, it operates on 12-48V with a power of 10 W. It has an insulation class of F (155°C) and an enclosure rating of IP 65 with a connector. Electrical connections are made via 3 spades conforming to DIN standards.
Construction
The valve body is made of brass, with a nickel-plated brass tube and stainless steel internal parts. Seals and gaskets are available in NBR, EPDM, or FKM. The coil is moulded in polyamide.
Options
Optional features include a ruby lower gasket, a normally open (NO) version, a PG9 connector conforming to DIN 43650 A, and an explosion-proof enclosure with protection II 2 G/D EEx d IIC T6 according to ATEX standards.
Repair Kits
Repair kits are available, including coils and complete plungers with O-rings. The ordering code for the repair kit is KIT30029 plus the seal material.
See more

Catalog excerpts

30029-1

ELECTROVANNE 3/2 NF 3 VOIES A COMMANDE DIRECTE SOLENOID VALVE 3/2 NC 3 WAYS DIRECT OPERATED TYPE 30029 SPECIFICATIONS TECHNIQUES TECHNICAL SPECIFICATIONS NF/NC Fluides admis : air – eau - gaz - huile légère Pression différentielle : 0 à 12 bar maxi Température du fluide : 100° C maxi Température ambiante : -10° à +50° C maxi Viscosité : 40 centistokes maxi Position de fonctionnement : indifférente Poids (avec bobine) : 280 g Temps d’ouverture ou fermeture: 20 millisecondes maxi Media: air – water – gas – light oil Pressure range : 0 to 12 bar max Media temperature : 100° C max Ambient temperature : -10° to +50° C max Media viscosity : 40 centistokes max Mounting : any position Weight (including coil) : 280 g Opening or closing time : 20 milliseconds maximum PRESSION PRESSURE Pression / Pressure (bar) ∅ passage (mm) ∅ seat (mm) Kv L/mn A2 E3 2⇒1 3⇐1 1.2 0.7 1.8 1.6 2 1.8 2 1.8 2.4 2.7 2.7 CA / AC 0 12 12 12 12 0 10 10 10 10 0 8 8 8 8 0 6 6 6 6 0 4 4 4 4 Etanchéité seals Fluid temp. Max °C Codification pour commande Voir tableau des codifications Code to order See table of references NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM 60 100 100 60 100 100 60 100 100 60 100 100 60 100 100 31229+107001+voltage+option 31229+307001+voltage+option 31229+207001+voltage+option 31629+107001+voltage+option 31629+307001+voltage+option 31629+207001+voltage+option 32029+107001+voltage+option 32029+307001+voltage+option 32029+207001+voltage+option 32429+107001+voltage+option 32429+307001+voltage+option 32429+207001+voltage+option 33029+107001+voltage+option 33029+307001+voltage+option 33029+207001+voltage+option CC / DC 3.8 3 CC / DC 2.5 2.4 CA / AC 1.8 2 mini eau - huile / water - oil 1.3 3 3/2 NF / 3/2 NC 2 air - gaz / air - gas CARACTERISTIQUES ELECTRIQUES ELECTRICAL DATA Tension / voltage (-10% + 15%) Durée d’enclenchement 100% Continuous duty 100% Au maintien Holding 26 VA ∼ 12-24-48-110-230 (50 ou/or 60 Hz) A l’appel Inrush Degré de protection Enclosure IP 65 avec connecteur with connector 14 VA 30 = 12-24-48 Classe d’isolation Insulation class F 155°C Puissance / Power Taille Size 10 W Raccord électrique Electrical connections 3 fiches 3 spades DIN 43650 DIN 40050 VDE 0110

 Open the catalog to page 1
30029-2

ELECTROVANNE 3/2 NF 3 VOIES A COMMANDE DIRECTE SOLENOID VALVE 3/2 NC 3 WAYS DIRECT OPERATED TYPE 30029 ENCOMBREMENT OVERALL DIMENSIONS CONSTRUCTION CONSTRUCTION Corps : laiton Tube : laiton nickelé Pièces internes : acier inoxydable Joints et clapets : NBR ou EPDM ou FKM Bobine surmoulée : polyamide Body : brass Tube Internal parts : nickel plated brass Seals and gaskets : NBR or EPDM or FKM Moulded coil : polyamide OPTIONS OPTIONS Clapet inférieur : RUBIS Version NO Connecteur PG9 – DIN 43650 A Capot anti-déflagrant : mode de protection II 2 G/D EEx d IIC T6 suivant ATEX Lower gasket: RUBY NO...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.