Product catalog summary
Technical Specifications
The solenoid valve is available in two configurations: Normally Closed (NC) or Normally Open (NO), with direct operation and in-line passage. It is suitable for various fluids including air, water, gas, light oil, and vacuum. The valve operates within a pressure range of 0 to 12 bar and can handle fluid temperatures up to 60°C. The ambient temperature range is -10°C to +50°C, and the maximum viscosity is 40 centistokes. The valve can be mounted in any position and weighs 170 grams with the coil. The opening or closing time is a maximum of 20 milliseconds.
Pressure Specifications
The valve is available in different port sizes and seat diameters, with corresponding Kv values for flow rates. The sealing materials include NBR, EPDM, and FKM, all suitable for fluid temperatures up to 60°C. Specific codes are provided for ordering based on the desired configuration and options.
Electrical Data
The valve operates on AC voltages of 12, 24, 48, 110, and 230 volts (50 or 60 Hz) with an inrush power of 26 VA and holding power of 14 VA. For DC, it operates on 12, 24, and 48 volts with a power consumption of 10 W. The insulation class is F (155°C), and the enclosure is rated IP 65 with a connector. Electrical connections are made via 3 spades conforming to DIN 43650, DIN 40050, and VDE 0110 standards.
Construction
The valve body is made of nylon reinforced with glass, while the tube and internal parts are stainless steel. Seals and gaskets are available in NBR, EPDM, or FKM. The coil is moulded in polyamide.
Options and Maintenance
Optional connectors include PG9 – DIN 43650 A. Maintenance kits are available, including coils and complete plungers with O-rings, identified by specific codes for ordering.
See more

Catalog excerpts

20012-1

ELECTROVANNE 2/2 NF ou NO 2 VOIES A COMMANDE DIRECTE SOLENOID VALVE 2/2 NC or NO 2 WAYS DIRECT OPERATED Passage en ligne / In line TYPE 20012 / 20013 SPECIFICATIONS TECHNIQUES TECHNICAL SPECIFICATIONS Fluides admis : air – eau - gaz - huile légère - vide Pression différentielle : 0 à 12 bar maxi Température du fluide : 60° C maxi Température ambiante : -10° à +50° C maxi Viscosité : 40 centistokes maxi Position de fonctionnement : indifférente Poids (avec bobine) : 170 g Temps d’ouverture ou fermeture: 20 millisecondes maxi Media: air – water – gas – light oil - vacuum Pressure range : 0 to 12 bar max Media temperature : 60° C max Ambient temperature : -10° to +50° C max Media viscosity : 40 centistokes max Mounting : any position Weight (including coil) : 170 g Opening or closing time : 20 milliseconds maximum PRESSION PRESSURE ∅ passage (mm) ∅ seat (mm) Kv L/mn 1.2 1 1.6 ∅ Raccord ∅ Port Pression / Pressure (bar) air - gaz / air - gas mini eau - huile / water - oil 0 12 12 12 0 12 12 12 0 12 12 12 0 12 12 12 4 0 12 5 12 5 1 0 12 12 12 12 1.6 1.8 0 12 12 12 12 2 2.3 0 12 12 12 12 2.4 3 0 9.5 9.5 9.5 9.5 3 4 0 6 6 6 21212+10+0181+voltage+option 21212+30+0181+voltage+option 21212+20+0181+voltage+option 21612+10+0181+voltage+option 21612+30+0181+voltage+option 21612+20+0181+voltage+option 22012+10+0181+voltage+option 22012+30+0181+voltage+option 22012+20+0181+voltage+option 22412+10+0181+voltage+option 22412+30+0181+voltage+option 22412+20+0181+voltage+option 23012+10+0181+voltage+option 23012+30+0181+voltage+option 23012+20+0181+voltage+option 21213+10+0180+voltage+option 21213+30+0180+voltage+option 21213+20+0180+voltage+option 21613+10+0180+voltage+option 21613+30+0180+voltage+option 21613+20+0180+voltage+option 22013+10+0180+voltage+option 22013+30+0180+voltage+option 22013+20+0180+voltage+option 22413+10+0180+voltage+option 22413+30+0180+voltage+option 22413+20+0180+voltage+option 23013+10+0180+voltage+option 23013+30+0180+voltage+option 23013+20+0180+voltage+option 12 3 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 60° 12 3 NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM NBR EPDM FKM 12 2.3 Codification pour commande Voir tableau des codifications Code to order See table of references 12 1.8 Fluid temp. Max °C CC / DC 1.2 2/2 NF / 2/2 NC CA / AC 2.4 2/2 NO / 2/2 NO CC / DC 2 1/8 GAZ 1/8 BSP CA / AC Etanchéité seals 6 CARACTERISTIQUES ELECTRIQUES ELECTRICAL DATA Tension / voltage (-10% + 15%) Durée d’enclenchement 100% Continuous duty 100% Au maintien Holding 26 VA ∼ 12-24-48-110-230 (50 ou/or 60 Hz) A l’appel Inrush Degré de protection Enclosure IP 65 avec connecteur with connector 14 VA 30 = 12-24-48 Classe d’isolation Insulation class F 155°C Puissance / Power Taille Size 10 W Raccord électrique Electrical connections 3 fiches 3 spades DIN 43650 DIN 40050 VDE 0110

 Open the catalog to page 1
20012-2

ELECTROVANNE 2/2 NF ou NO 2 VOIES A COMMANDE DIRECTE SOLENOID VALVE 2/2 NC or NO 2 WAYS DIRECT OPERATED Passage en ligne / In line TYPE 20012 / 20013 ENCOMBREMENT OVERALL DIMENSIONS TYPE 20012 NF TYPE 20013 NO CONSTRUCTION CONSTRUCTION Corps : nylon chargé verre Tube et pièces internes : acier inoxydable Joints et clapets : NBR ou EPDM ou FKM Bobine surmoulée : Polyamide Body : nylon reinforced with glass Tube and internal parts : stainless steel Seals and gaskets : NBR or EPDM or FKM Moulded coil : Polyamide OPTIONS OPTIONS Connecteur PG9 – DIN 43650 A Connector PG9 – DIN 43650 A KITS DE MAINTENANCE...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.