1. Catalogs
  2. Epsilon Technology
  3. Models 3911 Extensometer for Indirect Tensile Testing of Asphalt

Models 3911 Extensometer for Indirect Tensile Testing of Asphalt

Models 3911 Extensometer for Indirect Tensile Testing of Asphalt

Product catalog summary
Overview: The document describes the Model 3911 extensometer, designed for indirect tensile testing of asphalt, specifically for measuring resilient modulus. It highlights the advantages of the self-supporting design, which reduces errors from sample rocking and speeds up test setup.
Specifications:
  • Excitation: 5 to 10 VDC recommended, with a maximum of 12 VDC or VAC.
  • Output: 2 to 4 mV/V nominal, depending on the model.
  • Linearity: ≤0.20% of full scale measuring range.
  • Temperature Range: -40 °C to +100 °C (-40 °F to +210 °F).
  • Cable: 8 ft (2.5 m) ultra-flexible cable.
  • Specimen Size: Adjustable for 4 inch and 6 inch diameter specimens (100 mm and 150 mm).
Features:
  • Compatible with AASHTO TP31 and ASTM D4123 standards.
  • Full bridge, 350 ohm strain gaged design.
  • Meets ASTM class B-1 and ISO 9513, class 0.5 accuracy requirements.
  • Rugged, dual flexure design for improved performance.
  • Easy mounting with a breakaway feature for specimen fracture.
Options: Connectors for various test equipment and a shunt calibration module are available. The extensometer can be customized for special testing requirements.
Ordering Information: The Model 3911 is available in different measuring ranges, such as +0.030” (0.76 mm), +0.060” (1.50 mm), and +0.080” (2.00 mm). Customers are advised to consult the factory for additional ranges.
See more

Catalog excerpts

Models 3911 Extensometer for Indirect Tensile Testing of Asphalt-1

Model 3911 Available Versions: Consult factory for additional ranges. Example: 3911-0006: +0.060 inches (1.50 mm)measuring range 3911 extensometer S PECIFICATIONS Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. Output: 2 to 4 mV/V nominal, depending on the model Linearity: ≤ 0.20% of full scale measuring range, dependingon model Temperature Range: Standard is -40 C to +100 аC (-40 F to +210 аF) Cable: Integral, ultra-flexible cable, 8 ft (2.5 m) standard Specimen Size: Adjustable to fit both 4 inch and 6 inch diameter specimens (100 mm and 150 mm) > O PTIONS Connectors to interface to nearly any brand test equipment Shunt calibration module (see page 96) > 8.07205154.26.074.37111.5614.3 Contact Epsilon for your special testing requirements. TYPICAL 3911 DIMENSIONS:[mm] inches

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.